background image

Sargent Electrical Services Ltd. 

 

Copyright 2003 

Issue 1 

Page 1 of 4 

12 January 2005 

1  ELECTRICAL SYSTEM USING PSU 2005 

1.1  INTRODUCTION 

For the safe operation of all electrical equipment within your Caravan / Motorhome / Trailer Tent / 
Folding Camper it is important that you read and fully understand these instructions.  If you are unsure 
of any point please contact your dealer / distributor for advice before use. 

Your Caravan / Motorhome / Trailer Tent / Folding Camper has been fitted with an electrical system 
from Sargent Electrical Services Ltd. and incorporates the new PSU2005 power supply.  This unit 
provides protection for the 240v (mains) and 12v equipment, supplies 12v power and charges the 
internal leisure battery.  The electrical system complies with EN 1648-1 & -2 and BS7671. 

1.2  MAINS CONNECTION 

For your safety it is 

IMPORTANT

 that you follow these connections instructions each time your 

Caravan / Motorhome / Trailer Tent / Folding Camper is connected to a mains supply. 

A)  

Ensure suitability of the Mains Supply

.  Your Caravan / Motorhome / Trailer Tent / Folding 

Camper should only be connected to an approved supply that meets the requirements of BS7671.  
In most cases the site warden will hold information regarding suitability of supply.  If using a 
generator you also need to comply with the requirements / instructions supplied with the generator. 

B)  

Switch the PSU2005 unit OFF

.  Locate the red power switch on the PSU2005 and ensure the 

switch is in the OFF (0) position before connection to the mains supply. 

C)  

Connect the Hook-up Lead

.  Firstly connect the supplied hook-up lead (orange cable with blue 

connectors) to the Caravan / Motorhome / Trailer Tent / Folding Camper and then connect to the 
mains supply. 

D)  

Check Residual Current Device operation

.  Locate the RCD within the PSU2005 and ensure the 

RCD is switched on (lever in up position).  Press the ‘TEST’ button and confirm that the RCD is 
turned off (lever in down position).  Switch the RCD back to the on position (lever in up position).  If 
the test button failed to operate the RCD see section 1.4. 

E)  

Check Miniature Circuit Breakers

.  Locate the MCB’s within the PSU2005 (adjacent to the RCD) 

and ensure they are all in the ON (up) position. 

F)  

Turn the PSU2005 ON

.  Locate the red power switch on the PSU2005 and turn to the ON (I) 

position.  The switch will illuminate when turned on.      

G)  

Check correct Polarity

.  Locate the ‘Reverse Polarity’ indicator on the PSU2005 and ensure that 

the indicator is NOT illuminated.  If the indicator is illuminated see section 1.4.  Note that the 
reverse polarity indicator only works when the red power switch is in the ON position.  Also, 
reverse polarity indicator may momentarily flicker as the red power switch is turned on / off, this is 
normal and does not indicate a fault. 

H)  

Check operation of equipment

.  It is now safe to check the operation of the 12v and 240v 

equipment. 

PSU2005 Layout 

PSU2005 Specification 

 

Mains Input 230 Volts AC +/- 10% 

Frequency 50 Hz 

Output Voltage 13.5 Volts nominal 

Output Current 12 Amps nominal  

(150 Watts) 

 

 

www.foldingcampers.net

Содержание PSU 2005

Страница 1: ...he PSU2005 and ensure the switch is in the OFF 0 position before connection to the mains supply C Connect the Hook up Lead Firstly connect the supplied hook up lead orange cable with blue connectors to the Caravan Motorhome Trailer Tent Folding Camper and then connect to the mains supply D Check Residual Current Device operation Locate the RCD within the PSU2005 and ensure the RCD is switched on l...

Страница 2: ...ttery fluid Please see instructions supplied with the battery Note Do not over discharge the battery One of the most common causes of battery failure is when the battery is discharged below the recommended level of approximately 10 5v Discharging a battery below this figure can cause permanent damage to one or more of the cells within the battery 1 4 FAULT TABLE Fault Possible Cause Proposed Fix C...

Страница 3: ...Volts 0 to 16 Amps 10 OUTPUT 230v RCD protected 3 x MCB outputs of 10 10 and 6A via 2 x 9 way connectors INPUT 12v 2 x 20A battery inputs via 4 and 12 way connectors OUTPUT 12v 20A total output protected by 7 fused outputs via a 12 way connector Integrated CHARGER Input 220 240 Volts AC 10 Frequency 50 Hz 6 Current 1 7A max DC Output 13 5 Volts nominal Current 12 Amps max 150 Watts IP rating IP31 ...

Страница 4: ...chnical Director Sargent Electrical Services Ltd Unit 39 Tokenspire Business Park Woodmansey Beverley East Yorkshire United Kingdom 2 5 Electrical Connections 9 10 11 12 5 6 7 8 1 2 3 4 A B C D 4 WAY 12 WAY Fuse 6 OUT 6 spare B Fuse 7 OUT 4 Fuse 2 OUT 12 Fuse 4 OUT 3 Fuse 1 OUT 11 Fuse 3 OUT 2 12v IN 10 Fuse 3 OUT 1 12v IN 9 Fuse 5 OUT 8 spare D Fuse 5 OUT 7 spare C Fuse 6 OUT 5 Earth A View looki...

Отзывы: