1-800-727-5477 • www.sargentlock.com
A7133N 12/20
Copyright © 2020 SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or
in part without the express written permission of SARGENT Manufacturing Company is prohibited.
Installation Instructions
10 Line Cylindrical Lockset
Installation Instructions
•
#2 Phillips screwdriver
1
Package Contents
•
Push pin (provided)
DOOR
FRAME
Desired height
from finished floor
Template
Backset must
match lock (2-
3/8" or 2-3/4'
Door bevel
Figure 1
a. Mark & Drill Holes
b. Final Door Prep
c. Frame Prep for Strike
•
1/8" drill bit
•
7/16" drill bit
•
2-
1/8" Bore
•
1
" Bore
Figure 3
• Flat-bladed screwdriver
Figure 2
7/16" (11mm) hole
2-1/8"
(54mm)
hole
1-1/8"
(29mm)
2-1/4"
(57mm)
1" (29mm)
hole
5/32" (4mm)
Inside of Door
Outside of Door
(Secure Side)
1
2
3
4
5
6
7
8
4
2
9
10
11
12
13
14
16
17
15
Figure 4
Figure 1
Description
Req
1
Inside Lever
1
2
Rose Scalp
2
3
Screws – mounting
plate #6 x 3/4" self-
tapping
2
4
Spacer bushing
2
5
Inside rose assembly
1
6
Screws – through-
bolt #10-32 x 1-1/4"
2
7
Lockbody
1
8
Outside rose
assembly
1
9
Cylinder spacer
1
10
Cylinder
1
11
Outside lever
1
12
Key
1
13
Push pin
1
14
Latch
1
15
Screws – latch &
strike #8-32 x 3/4"
4
16
Strike
1
17
Strike box
1
Tools Required
• All doors should be properly reinforced for lock support. If support is not provided, contact door manufacturer.
• For all metal door preparations, use template A4375 (Not included. See website to download), EXCEPT for functions 10G70 or 10G71
which use template 4409 (not included), or functions 10U93, 10U94, and 10U94-2 which require template A4375.
• For all wood door preparations use template A6719 (included), EXCEPT for functions 10G70 & 10G71.
• Template information is available on our website: www.sargentlock.com.
IMPORTANT: Deadlocking latch must
stop on the strike when the door is
closed.
#8-32 x 3/4"
Strike
Centerline of latch
front and strike
Screws (2)
Tighten after adjustment
IMPORTANT: Fold template onto high
edge of door bevel.
2
Door Preparation