- 8 -
4. Model specification
SY
2
000 –7R5 G
-
4
GP unification Model
description
Users check factory models through P0.00. P type is one lower power than G type.
E.g
:
If you need 11kw P type, 7.5kw G type could be selected as a replacement. Its input
current is the rated input current (20.5A) of 7.5kw G type, but its rated power is that of
11kw G type, and output current is the rated output current(25A) of 11kw G type.
Though inverter hardware of GP unification is different, there are some
optimization of software parameters for different load types .
P type model is only suitable for pump, fan etc light load models, can not work at the rated
current or more than the rated frequency for a long time.
terminal
TB
terminals TA and TC can reach 14
kinds. For details, please refer to the
introduction of F2.20 output
terminal function.
TA-TC: normally open.
Contact capacity: 250VAC /
2A (COSФ = 1);
250VAC / 1A (COSФ = 0.4),
30VDC /
1A.
TC
Power supply
port
10V
10V is the common power supply of
the analog input terminal circuit
The maximum output current is
20mA.
12V
12V is the common power supply
for digital signal input terminals
The maximum output current is
100mA.
GND
Analog signal and 10V, digital
signal and 12V power supply GND.
Analog signals and digital
signals common grounded.
Communicati
on port
485+
RS485 port
Standard RS485
communication interface, not
isolated from GND, please use
twisted pair or shielded wire.
485-
RS485 signal-port
Inverter Series
No.
Voltage
S2
Single-phase 220V
2
Three-phase 220V
4
Three-phase 380V
No.
Adaptation
R75
0.75kW
7R5
7.5kW
011
11kW
018
18.5kW
110
110kW
400
400kW
No.
Inverter Type
G
General type
P
Fan pump type