background image

INSTRUCTION MANUAL 

   

   

  

      VDC-D1785IRVP

Vandal-resistant IR Dome Camera

About this manual

 

Before installing and using the camera, please read this manual 

carefully.  Before to keep it handy for later reference.

Dimension:mm (inches)

Depending on the conditions of use, installation and environment, please be 
sure to make the appropriate settings and adjustments.  If you need help with 
installation and or settings, please  consult your dealer or authorized Sanyo 
Service Center.

  TROUBLESHOOTING

Before sending the camera out for repair, check the items below.  
If the problem persists after checking these items, consult your dealer or 
authorized Sanyo Service Center.

    If no image appears

 Is the coaxial cable attached securely?

 Are the power and voltage normal?

 Has the iris of the lens been adjusted correctly (with level volume)?

 Is there adequate illumination?

    If the image is unclear

 Is the monitor adjusted correctly?

 Is the lens in focus?

 Is the lens clean?

Dirt or 

fi

 ngerprints on the lens can adversely affect the image.  Gently wipe and 

dirt of fingerprints off the lens a soft cloth or lens cleaning paper and cleaning 

fl

 uid (commercially available).

  SERVICE

The camera is precision instrument.  Handle it carefully and always follow the 
safety precautions.  If the camera requires service, never try to repair it yourself 
or open the casing.  For servicing, maintenance, or repairs, consult your dealer  
or authorized Sanyo Service Center.

For EU Users

Please note:

Your SANYO product is designed and manufactured with high quality 
materials and componets which can be recycled and reused.
This symbol means that electrical and electronic equipment, at their end-of-
life, should be disposed of separately from your household waste.
Please dispose of this equipment at your local community waste collection/ 
recycling centre.
In the European Union there are separate collection systems for used 
electrical and electronic product. 
Please help us to conserve the environment we live in! 

This symbol mark and recycles system are applied only to EU countries and 
not applied to countries in other areas of the world.

 

 SANYO FISHER Sales (Europe) GmbH

 Stahlgruberring 4, D 81829 Munich, Germany

 SANYO Electric Co., Ltd.

 1-1, Sanyo-cho, Daito City, Osaka 574-8534, Japan

For Russian Users

 

 

This product certi

fi

 ed by of

fi

 cal certi

fi

 cation company which is  

 

 

 

authorized by Russian Federation.

 

 

ДЛЯ

 

ПОЛЬЗОВАТЕЛЕЙ

 

РОССИИ

 

 

Данная

 

продукция

 

сертифицирована

 

официальным

          

МО

04

 

органом

 

по

 

сертификации

 

Российской

 

Федераци

.

SPECIFICATIONS

  Appearance and speci

fi

 cations are subject  to change without prior notice.

PRECAUTIONS

 In case of a probelm

Do not use the unit if smoke or a strange odor comes 
from the unit, or if it seems not to function correctly.  Turn 
off the power immediately and disconnect the power 
cord, and then consult your dealer or an Authorized 
Sanyo Service Center. 

 Do not modify

Do not modify the cabinet and camera, as it maybe 
dangerous and cause of damage to the unit.  For repairs, 
consult your dealer or an Authorized Sanyo Service 
Center.

 Do not put objects inside the unit

Make sure that no metal objects or 

fl

 ammable substance 

get inside the unit.  If used with a foreign object inside, it 
could cause a 

fi

 re, a short-circuit or damage.  Be careful 

to protect the unit from rain, sea water, etc.  If water or 
liquid gets inside the unit, turn off the power immediately 
and disconnect the power cord, and then consult your 
dealer or an Authorized Sanyo Service Center.

 Be careful when handling the unit

To prevent damage, do not drop the unit or subject it to 
strong shock or vibration.

 Do not install this unit close to magnetic 

fi

 elds

The magnetic 

fi

 elds may result in unstable operation.

 Protect from humidity and dust

To prevent damage, do not installl the unit where there is 
greasy smoke or steam, where the humidity may get too 
high, or where there is a lot of dust.

 Protect from high temperatures

Do not install close to stoves, or other heat sources, such 
as spotlights, etc., or where it could be subject to direct 
sunlight, as this could cause deformation, discoloration or 
damage. 

 Cleaning

* Dirt can be removed from the cabinet by wiping it with 
a soft cloth.  To remove stains, wipe with a soft cloth 
moisteried with a soft detergent solution and wrung dry, then 
dry by wiping with a soft cloth.
* Do not use benzine, thinner or other chemical products 
on cabinet, as this may cause deformation and paint 
peeling.  Before using a chemical cloth, make sure to read 
all accompany instructions.  Make sure that no plastic or 
rubber material comes into contact with the cabinet for a 
long period of time, as this may cause damage or paint 
peeling.

 Degree of protection: IP67

This unit has been certi

fi

 ed to IP67 standards when properly 

installed.  Use only an IP67 certified enclosure or an 
electrica box.  Ensure all openings in enclosure are sealed 
as per manufacture's instructions.

 

 

 

       

Sanyo Electric Co., Ltd     

                                                                                         Printed in Taiwan  

            

CAUTION

Since the conduit hole cover is not waterproof-
finished, always be sure to seal the cover entirely 
by caulking, for example, upon completion of 
installation.
Make sure to perform waterproo

fi

 ng properly to the 

ceiling or wall where you are installing the unit.
When setting up this camera, make sure that it 
is installed securely.  Check that the installation 
location is strong enough to bear the camera 
unevenness.  In addition, do not touch the camera 
unit except when settings and adjustment are 
necessary. 

1.

 Loosen the 3 

fi

 xing screws using the supplied   

hexagonal wrench and remove the dome cover.

2.

 Inceiling : Place the supplied "Mounting template 

for inceiling" on the mounting surface, and mark 3 
positions shown in.
or
Surface : Place the supplied "Mounting template for 
surface" on the mounting surface, and mark 4 positions 
shown in.

3.

 Drill holes at positions as marked and insert the 

supplied screw holes in the holes.

4.

 Cut a hole in the ceilling or the wall for routing the 

cables.   

5.

 Pass the power cable, video cable and UTP cable 

from the camera unit  through the cable hole in the 
ceilling or the wall.  

6.

 Align the unit mounting holes of the camera unit with 

the holes in the ceilling or the wall.

7. 

Secure with the supplied mounting screws.

8.

 Carry out the settings and adjustments for the 

camera.  Refer to "CONNECTIONS AND SETTINGS" 
for camera settings and lens adjustments.8.

* When  routing the cables on ceiling or wall surface:
Loosen the conduit hole cover 

fi

 xing screw on the back 

of the camera unit base with the hexagonal wrench, 
open the cover, and pass the connection cables 
through the conduit hole.
HINT
(#1) Press the grip portion to remove the mask before 
adjustment.

INSTALLATION

For Inceiling Mount 

installation

-Inceiling type-

For Surface Mount 

installation

-Surface type-

Model Number 

VDC-D1785IRVP

Scanning system

PAL standard 625 lines, 50fields/sec.

Image sensor

1/3" Interlace CCD sensor

Number of effective pixels

752(H) x 582(V)

Horizontal resolution

540 TV lines (Typical)

Lens

f=3.7 to 12mm, F1.4, IR lens

Minimum illumination (50IRE)

0.7lx LED-Off, 0.0lx LED-ON

Video/ Monitor output

1.0Vp-p (75ohms, composite)

Video S/N ratio

More than 48dB

Day & Night

True Day/ Night

Backlight compensation

ON/ OFF

White balance

Auto

Auto iris drive

DC 

AGC gain

ON/ OFF

Flickerless

ON/ OFF

Gamma correction

0.45

Sync system

Internal

Unshielded Twisted Pair

Passive type

IR LED

18 pcs

IR distance

20m

IR wavelength

850nm

Operating temperature

-10°C to +50°C (14°F to 122°F)

Operating humidity

Less than 90% (no condensation)

Power supply

12VDC+/-10%, 24VAC+/-10%, 50Hz 

Power consumption

7.0w

Weather Protection class

IP67

Dimensions (

ĭ

 x H)

150.1 x 129mm (5.9" x 5.1)

Weight

Approx.  0.95kg(33.5oz) In-ceiling mount
1.20kg(43.7oz) Surface mount
1.Wall Mounting template……. .…..1
2.Inceiling Mounting template… .…1
3.Installation Manual……… . .….…1
4.Conduit cap……………… .……...1
5.Fixing screw (P4*31TP)….……...4
6.Wall plugs…………… ...…….…..4
7.Fixing scerw (M4x0.7P x15mm)..3
8.Monitor out cable…………………1
9.Hexagonal wrench……………..1
10.Surface-mount adaptor………..1

Accessories

(#1)

(B)

(A)

(C)

(D)

(E)

(F)

Отзывы: