Содержание SAP- FR99EH

Страница 1: ...ANUAL INDOOR UNIT SAP FR99EH SAP FTR129EH SPLIT SYSTEM AIR CONDITIONER SAP FR99EH Floor Mounted SAP FTR129EH Ceiling Mounted SM940013 Model No Product Code No SAP FR99EH 1 85208179 0 8180 279 0 07 2002 SAP FTR129EH 1 85208181 ...

Страница 2: ...ring to touch the refrigerant tubing compressor or any moving parts of the fan Do not use multi core cable when wiring the power supply and control lines Use separate cables for each type of line When transporting Be careful when picking up and moving the indoor and outdoor units Get a partner to help and bend your knees when lifting to reduce strain on your back Sharp edges or thin aluminium fins...

Страница 3: ... Protection Cooling Dry and Heating 17 5 6 Overload Prevention Heating 18 5 7 Cold Draft Prevention Heating 19 5 8 Defrosting Operation Heating 20 6 TROUBLESHOOTING 22 6 1 Check before and after troubleshooting 22 6 2 Air conditioner does not operate 23 6 3 Some part of air conditioner does not operate 27 6 4 Air conditioner operates but abnormalities are observed 29 6 5 If a sensor is defective 3...

Страница 4: ...erant Refrigerant tube kit Air clean filter Dimensions Weight Unit dimensions Height mm Width mm Depth mm Package dimensions Height mm Width mm Depth mm Weight Net kg Shipping kg Shipping volume m3 DATA SUBJECT TO CHANGE WITHOUT NOTICE ON OFF 24 hours Daily program 1 hour OFF 3 and Auto 1 Hi Manual Manual Washable Anti Mold 51 Flare type 6 35 1 4 9 52 3 8 R22 or R407C Optional Optional 700 560 200...

Страница 5: ...e kit Air clean filter Dimensions Weight Unit dimensions Height mm Width mm Depth mm Package dimensions Height mm Width mm Depth mm Weight Net kg Shipping kg Shipping volume m3 DATA SUBJECT TO CHANGE WITHOUT NOTICE 0 21 995 280 23 5 31 5 680 900 190 770 Auto Washable Anti Mold 55 Flare type Wireless remote control unit ON OFF 24 hours Daily program 1 hour OFF 3 and Auto 1 Hi Manual See catalogue w...

Страница 6: ...t W Coil resistance Ambient temp 25 C Ω Safety devices Type Operating temp Open C Close Run capacitor µF VAC Heat Exch Coil Coil Rows Fin pitch mm Face area m DATA SUBJECT TO CHANGE WITHOUT NOTICE 1 4 450 WHT VLT 92 105 VLT YEL 62 71 GRY BRN 78 90 1 Thermal protection 150 10 Automatic 0 185 XR99EH SA RCS 6HPS4E G Cross flow K35406 M01892 1 4 1196 Aluminium plate fin Copper tube 1 27 GRY WHT 545 63...

Страница 7: ... Motor Type Model Rating No of poles rpm Nominal output W Coil resistance Ambient temp 25 C κΩ Heat Exch Coil Coil Rows Fin pitch mm Face area DATA SUBJECT TO CHANGE WITHOUT NOTICE 0 29 65 XR129EH SA Microprocessor 250 V 3 15 A RCS 6HPS4E G Cross flow 2 Ø 130 L 180 K48407 M01596 1 4 1160 21 GRY WHT 298 343 ORG YEL 211 243 Thermal protection 145 5 WHT PNK 421 485 WHT VLT 93 5 108 VLT ORG 93 5 108 A...

Страница 8: ...econdary Capacity Coil resistance Ω at 21 C Thermal cut off temp Thermistor Coil sensor TH1 Resistance κΩ Thermistor Room sensor TH2 Resistance κΩ KTEC 35 S6 25 C 5 0 4 PCB 41E S14 Primary WHT WHT 205 10 Secondary BRN BRN 2 10 150 C 0 C 15 0 5 ATR J105 AC 230 V 50 60 Hz 19 V 0 526 A 10 VA 8 ...

Страница 9: ...2 DIMENSIONAL DATA SAP FR99EH Unit mm 9 ...

Страница 10: ...SAP FTR129EH Unit mm Unit mm 10 ...

Страница 11: ...r velocity Flap angle 60 45 Floor mounted Cooling 0 1 2 3 4 5 6 7 3 2 1 0 Horizontal distance m Axis air velocity m s Vertical distance m 0 1 2 3 4 5 6 7 3 2 1 0 Horizontal distance m Axis air velocity m s Vertical distance m Room air temp 20 C Fan speed High Axis air velocity Flap angle Heating 0 20 11 ...

Страница 12: ...eed High Heating 0 1 2 3 4 5 6 7 1 0 2 3 Horizontal distance m Axis air velocity m s Vertical distance m Axis air velocity Flap angle 45 30 Ceiling mounted 0 1 2 3 4 5 6 7 1 0 2 3 Horizontal distance m Axis air velocity m s Vertical distance m Axis air velocity Flap angle 60 80 12 ...

Страница 13: ...4 ELECTRICAL DATA 4 1 Electric Wiring Diagrams SAP FR99EH SAP FTR129EH 13 ...

Страница 14: ...ontrol circuit has a built in automatic time delay to allow the internal pressure to equalize As a protective measure the control circuit switches the compressor OFF after 5 minutes or more of compressor operation Thermo ON When the room temperature is above T 1 C T C is set temperature Compressor ON Thermo OFF When the room temperature is equal to or below set temperature T C Compressor OFF 3 min...

Страница 15: ...ective measure the control circuit switches the compressor OFF after 5 minutes or more of compressor operation Thermo ON When the room temperature is below T 1 C T C is set temperature Compressor ON Thermo OFF When the room temperature is equal to or above set temperature T C Compressor OFF 1 Refer to 5 7 Cold Draft Prevention NOTE 5 minutes 5 minutes ON OFF ON OFF Compressor OFF ON OFF ON OFF Out...

Страница 16: ... calculates the difference between the set temperature and the room temperature and automatically switches to COOLING or HEATING mode to maintain the desired temperature Room temp Set temp COOL Room temp Set temp HEAT This means that if the room temperature is higher than or equal to the set temperature COOLING operation begins If the room temperature is lower than the set temperature HEATING oper...

Страница 17: ...aged by overcurrent When the compressor current exceeds either H1 A for 2 seconds or H2 A for 8 seconds both compressor and outdoor fan stop Trip At the same time operation lamp in front of the indoor unit flashes After 3 minutes this function automatically releases and resumes operation until tripping repeats 8 times If the tripping repeats 9 times or more the unit stops its operation The compres...

Страница 18: ... heat exchange coil rises above A1 C the outdoor fan stops The operation temperature shown as A1 A2 A3 and A4 in the chart differ by models NOTE ON ON OFF ON H or M or L H H M M L M A1 A2 A3 A4 Indoor heat exch coil temp C Outdoor fan Indoor fan Compressor Compressor current detection When the compressor current rises above B1 A and if the indoor fan is L low speed then the fan speed changes from ...

Страница 19: ...ion is working Indoor fan operates in LL until indoor heat exchange coil temperature reaches 32 C In case of after releasing the defrosting indoor fan halt its operation until the coil temperature reach 32 C When the coil temperature rises above Tc C indoor fan operates in set speed The operation temperature shown as Tc in the chart differs by models NOTE OFF ON OFF or Set speed Indoor fan Standby...

Страница 20: ...ting time of compressor is longer than 3 hours temperature of indoor heat exchanger coil immediately before thermo goes off is below Td 5 6 C etc NOTE The values shown as Td differs according to the models Td Reverse cycle defrosting operation compressor ON outdoor fan OFF 4 way valve OFF indoor fan cold draft prevention mode Releasing of defrosting Defrosting operation lasts 8 to 12 minutes max c...

Страница 21: ... 60 seconds Start of defrosting Release of defrosting OFF OFF Release of cold draft prevention Compressor Outdoor fan Solenoid coil 4 way valve Indoor fan Standby lamp Indoor heat exch coil temp ON ON Set speed Set speed 1 4 or 8 seconds 2 seconds Tc C 32 C LL NOTE 1 Refer to 5 7 Cold Draft Prevention 21 ...

Страница 22: ...outdoor unit from the indoor unit 6 1 3 Check power supply Check that voltage is in specified range 10 of the rating Check that power is being supplied 6 1 4 Check lead wires and connectors in indoor and outdoor units Check that coating of lead wires is not damaged Check that lead wires and connectors are firmly connected Check that wiring is correct WARNING Hazardous voltage can cause ELECTRIC SH...

Страница 23: ... insulation resistance of electrical parts in outdoor unit NO Set circuit breaker to OFF Measure insulation resistance of electrical parts in indoor unit 1 Remove inter unit wires from terminal plate in outdoor unit Measure insulation resistance of outdoor unit 2 Remove inter unit wires from terminal plate in indoor unit Then pull the power plug out of the wall outlet Measure insulation resistance...

Страница 24: ...ON selector switch to ON Indoor PCB Ass y is defective NO Check power supply Power is being supplied to the indoor unit Circuit breaker is tripped Power failure Reset breaker Wait for recovery or contact power company Replace with suitable one larger capacity NO Check capacity of circuit breaker Capacity of circuit breaker is suitable Measure resistance of outdoor fan motor winding Measure resista...

Страница 25: ...ry and secondary winding of transformer TR Indoor PCB Ass y is defective OK OK Measure resistance of indoor and outdoor fan motor winding FM Measure resistance of compressor motor winding CM OK Measure resistance of 4 way valve s winding PR Replace the fuse If fuse has been blown OK Try to run with another remote control unit First remote control unit is defective Check for residue buildup on tran...

Страница 26: ... temperature by temperature setting button button Outdoor unit still does not run Remote control unit is defective Try to run using another remote control unit COOL OK NO Is room temperature too high Try to raise setting temperature by temperature setting button button Outdoor unit still does not run Try to run using another remote control unit HEAT Remote control unit is defective 26 ...

Страница 27: ...ance of outdoor fan motor winding Check fan motor capacitor Measure resistance of flap motor winding Fan cannot be turned OK Check fan rotation Turn fan gently once or twice by hand Check fan casing foreign matter on inside Fan motor burnout or foreign matter in bearings Remove foreign matter or repair Repair or replace Measure resistance of indoor fan motor winding Check fan motor capacitor OK Me...

Страница 28: ...sistance of compressor motor winding NO YES YES Overload relay is working Either OLR T or OLR A YES Temperature of compressor is abnormally high Refrigerant gas shortage Charge refrigerant gas R22 Rotor may be locked up C1 Measure Power supply voltage The voltage is too low No 28 ...

Страница 29: ...CB Ass y is defective Check voltage between terminals No 1 and No 4 at the terminal plate AC 220 240V No voltage appears Remote control unit may be defective Measure resistance of 4 way valve s winding Receiver in lamp Ass y may be defective COOL HEAT Check voltage between terminals No 1 and No 4 at the terminal plate 0V HEAT COOL 29 ...

Страница 30: ...e Possibility of gas shortage YES Check position of remote control unit Cool or warm air from air conditioner reaches position directly Change position of remote control unit Wide and narrow tubes between indoor unit and outdoor unit are insulated Insulate both wide and narrow tubes separately and then tape together Measure temperature of suction and discharge air of air conditioner Charge refrige...

Страница 31: ...h on and off when either indoor coil thermistor or room air thermistor is defective At the same time the outdoor unit will stop Indoor unit will operate only for ventilation NOTE Operation lamp on front side of indoor unit is flashing on and off YES Replace the thermistor Indoor coil thermistor TH1 or room air thermistor TH2 is defective YES 31 ...

Страница 32: ...d measure the resistance by placing a probe on each terminal screw on the terminal plate Fig 2 Note that the ground line terminal should be skipped for the check 7 1 4 Measurement of Insulation Resistance for Electrical Parts Disconnect the lead wires of the desired electric part from terminal plate capacitor etc Similarly disconnect the connector Then measure the insulation resistance Figs 3 and ...

Страница 33: ...d then place a probe on the capacitor terminals as shown in Fig 7 Observe the deflection of the pointer setting the resistance measuring range of the multimeter to the maximum value The capacitor is good if the pointer bounces to a great extent and then gradually returns to its original position The range of deflection and deflection time differ according to the capacity of the capacitor Fuse PCB ...

Страница 34: ...ss on the PCB of each indoor unit with the switch positions of its remote control unit To change address on PCB 1 Set the switch n 2 to off position on the address dip switch S01 see detail on figure To change address on Remote Control Unit NB Once changed you cannot restore the original address 1 Remove the batteries before changing the address 2 Remove tab marked A to change the address of the r...

Страница 35: ...SANYO Airconditioners Europe S r l Via Bisceglie No 76 20152 Milano Italy ...