6. ELECTRICAL DATA
6-1. Electrical Characteristics
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
240V Single phase 50Hz
Rating Conditions
Running Amps.
A
0.37
0.54
6.25
9.6
Power Input
kW
0.041
0.122
1.443
2.280
Full Load Conditions Running Amps.
A
0.37
0.54
8.65
12.5
Power Input
kW
0.041
0.122
1.993
2.840
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit
SAP – KR224GJ
Outdoor Unit
SAP – CR224G
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
240V Single phase 50Hz
Rating Conditions
Running Amps.
A
0.31
0.54
6.05
6.90
Power Input
kW
0.035
0.122
1.473
1.630
Full Load Conditions Running Amps.
A
0.31
0.54
8.65
9.50
Power Input
kW
0.035
0.122
1.993
2.150
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit
SAP – KR184GJ
Outdoor Unit
SAP – CR184G