18
5-3. Cooling Capacity
Indoor Unit
SAP – KR184GJ
Outdoor Unit
SAP – CR184G
240V Single Phase 50Hz
RATING CAPACITY
5.15 kW
AIR FLOW RATE
940 m
3
/h
EVAPORATOR
CONDENSER
ENT. TEMP. °C
OUTDOOR AMBIENT TEMP. °C
W.B.
D.B.
30
35
40
43
TC
4.74
4.51
4.24
3.90
CM
1.29
1.39
1.56
1.81
21
SHC
3.40
3.29
3.16
3.01
15
23
SHC
3.88
3.77
3.64
3.48
25
SHC
4.35
4.24
4.11
3.90
27
SHC
4.74
4.51
4.24
3.90
29
SHC
4.74
4.51
4.24
3.90
31
SHC
4.74
4.51
4.24
3.90
TC
5.08
4.84
4.55
4.19
CM
1.33
1.43
1.60
1.85
21
SHC
2.92
2.81
2.68
2.52
17
23
SHC
3.39
3.28
3.15
3.00
25
SHC
3.86
3.76
3.63
3.47
27
SHC
4.34
4.23
4.10
3.94
29
SHC
4.81
4.70
4.55
4.19
31
SHC
5.08
4.84
4.55
4.19
TC
5.41
# 5.15
4.84
4.45
CM
1.37
1.47
1.65
1.90
21
SHC
2.41
2.30
2.18
2.02
19
23
SHC
2.89
2.78
2.65
2.49
25
SHC
3.36
3.25
3.12
2.97
27
SHC
3.83
3.72
3.60
3.44
29
SHC
4.31
4.20
4.07
3.91
31
SHC
4.78
4.67
4.54
4.39
TC
5.73
5.46
5.13
4.72
CM
1.41
1.51
1.69
1.95
23
SHC
2.37
2.27
2.14
1.99
21
25
SHC
2.85
2.74
2.62
2.46
27
SHC
3.32
3.22
3.09
2.94
29
SHC
3.80
3.69
3.56
3.41
31
SHC
4.27
4.16
4.04
3.89
TC
6.07
5.73
5.37
4.99
CM
1.45
1.55
1.73
1.99
23
25
SHC
2.31
2.19
2.06
1.93
27
SHC
2.78
2.66
2.53
2.40
29
SHC
3.26
3.14
3.01
2.88
31
SHC
3.73
3.61
3.48
3.35
TC :
Total Cooling Capacity (kW)
SHC : Sensible Heat Capacity (kW)
CM :
Compressor Input (kW)
Rating conditions (#Mark) are
Outdoor Ambient Temp. 35°C D.B.
Indoor Unit Entering Air Temp. 27°C D.B. / 19°C W.B.