background image

INSTRUCTION MANUAL

FIRST MADE FOR

SAP-KC18AM, KC18AGH

MATERIAL OR MODEL

*PAPER-JO

DIMENSION OR MAKER

WOODFREE 80gm

COLOR

BLACK Print

E

Z

I

S

4

A

E

T

O

N

APPROVALS

N.Yamazaki

2009/

Nov

/2

6

CHECK

Tai C.S

2009/

Nov

/2

5

DESIGN

Tai C S

2009/Sep/08

O

N

.

R

S

N

O

I

S

I

V

E

R

E

T

A

D

S

L

A

V

O

R

P

P

A

DRAWN

REMARKS:

PART CODE

SAMS ONLY

85S-6-4181-002-00-0

PART NAME

EXPLANATORY BOOKLET

1

A

P.g 33, additional Flare Nut

Tai C.S

22 Dec 09

1

Содержание SAP-C18AGH

Страница 1: ...gm COLOR BLACK Print E Z I S 4 A E T O N APPROVALS N Yamazaki 2009 Nov 26 CHECK Tai C S 2009 Nov 25 DESIGN Tai C S 2009 Sep 08 O N R S N O I S I V E R E T A D S L A V O R P P A DRAWN REMARKS PART CODE SAMS ONLY 85S 6 4181 002 00 0 PART NAME EXPLANATORY BOOKLET 1 A P g 33 additional Flare Nut Tai C S 22 Dec 09 1 ...

Страница 2: ...2010 SANYO Electric Co Ltd Save These Instructions INSTRUCTION MANUAL Split System Air Conditioner COOL DRY MODEL SAP K18AM AMS HEAT PUMP MODEL H A 1 P H A 2 1 K P A S INDOOOR UNIT OUTDOOR UNIT SAP C18AM AMS SAP K18AGH SAP C18AGH ...

Страница 3: ...s remote control unit 5 Clean and care 6 Troubleshooting Installation Service 7 Notices for installation 8 Installation dimension diagram 9 Install indoor unit 10 Install outdoor unit 12 Check after installation and Test operation Product Information If you have problems or questions concerning your Air Conditioner you will need the following information Model and serial numbers are on the namepla...

Страница 4: ... may lead to the fall of the unit and cause the Do not step on the top of the outdoor unit or place things on it As falling off the outdoor unit can be dangerous Don tleavewindowsanddoors openforalongtimewhileoperating theairconditioner If abnormal phenomenon like Cut Off Power If abnormal phenomenon Don t attempt to repair the air conditioner by yourself Each unit must be properly grounded with a...

Страница 5: ...osition Louver of left right direction Flap of upward downward position FAN OPER SWIN G AM C ON ON O FF FA N TEMP TEMP MOD E TIME CANCE L TIME SWING SLEE P T ON T OF F CLOC K Do not use the air conditioner for other purposes such as drying clothes preserving foods etc Do not place a space heater near the air conditioner CO toxicosis may occur as a result of imcomplete burning Do not insert your ha...

Страница 6: ...e the auto defrosting function will act and the heat running will stop for 8 10 minutes 2 During the auto defrosting function both the fan motors of indoor unit and outdoor unit will stop operate 3 During the defrosting function the indoor indicator flashes and the outdoor unit may emit vapor This is due to the defrosting it is not malfunction 4 After defrosting finished the heating will recover a...

Страница 7: ...er the relative humidity is above 80 doors and windows are opened when cooling or dehumidifying for a long time there may have dew drip off near the air vent COOLING HEATING Temperature Indoor air temperature Outdoor air temperature Max Min Max Min 32 C DB 23 C DB 21 C DB 15 C DB 27 C DB 20 C DB 43 C DB 26 C DB 21 C DB 24 C DB 18 C DB 5 C DB 6 C DB COOL running HEAT running DRY running Outdoor tem...

Страница 8: ... Power cable 2 Remote control 3 Front Panel 4 Filter 5 Silver Ion Filter 6 Guide Louver 7 Receiver 8 Indicator Cool Dry Fan Heat Run Set Temp 9 Wall Pipe 10 Bind Tape 11 Connection Wire Drainage Pipe 12 Connection Pipe 13 6 11 12 Air intake Air outlet Air inlet Air outlet 9 10 13 3 1 4 Wireless remote control 2 7 8 Operation and Maintenance Only for SAP K18AMS ...

Страница 9: ...LOW 3 Set temperature 16 30 C When set to 23 C Symbols 4 Timer 24 hour ON Timer 24hour OFF Timer 5 Sleep 6 Confirmation of transmission 7 Clock indication 8 Sweep indication Displayed when setting temperature Displayed when setting timer Displayed the clock AUTO FAN HEAT AUTO Heat Pump model Only 9 Light 10 Blow 11 Turbo F C ON OFF 12 TEMP OPER 13 Lock Operation and Maintenance ...

Страница 10: ...etting button ON OFF operation button TIMER ON button TIMER OFF button Signal Transmitter MODE operation button FAN SPEED Selector button SLEEP button CLOCK button SWING button The air conditioner starts at the set time The air conditioner stops at the set time To select AUTO COOL DRY FAN or HEAT mode TIMER ON button TIMER OFF button MODE selector button DRY COOL When choosed this setting the air ...

Страница 11: ...direction which circurlarly change as OFF When the guide louver start to swing up and down if turn off the Swing the air guide louver will stop at the current position refer P g 14 for more detail Use this button to set the clock How it Works Press clock button signal blink and display Within 5 seconds the value can be adjusted by pressing or button if press this button continuously for 2 seconds ...

Страница 12: ...tion the temperature can not be adjust Under HEAT operation the initial value is 28 C 82 F Under other operation the initial value is 25 C 77 F Set the FAN SPEED selector button to the setting you want Press the automatically button and set the air blow direction as desired or AUTO Auto fan speed High fan speed Middle fan speed Low fan speed Under Dry mode the fan speed is automatically set to LOW...

Страница 13: ...e status of the timer while it is counting down press the TIMER ON button Cancellation Procedure Press the TIMER ON button again to cancel After the length of time set for TIMER OFF elapses the unit stops operating The display depicted at left indicates that the air conditioner will stop operating in 10 A M Setting procedure STEP 1 STEP 2 Press the TIMER OFF button Press the T OFF button which adv...

Страница 14: ...rgy without sacrificing comfort This function is convenient when gentle cooling is needed Setting temperature Press the SLEEP button 1 C 1 C 60 min Time 60 min Setting temperature Press the SLEEP button 60 min 60 min Time 1 C 1 C When the SLEEP mode is selected the air conditioner automatically lowers the temperature setting 1 C when 60 minutes have passed after the selection was made and then ano...

Страница 15: ...y How it works BLOW Operation During COOL or HEAT mode if start this function the unit will run at super high fan speed to cool or heat quickly so that the ambient temp approachs the preset temp as soon as possible How it works TURBO Operation It s a special selective button for the users who are not accustomed to the light at sleeping When setting the light function the mark will display on the r...

Страница 16: ...on the unit will stop swinging and present position of guide louver will be kept immediately 2 Under swing up and down mode when the status is switched from off to if press this button again 2s later status will switch to off status directly if press this button again within 2s the change of swing status will depend on the circulation sequence stated below About switch between Fahrenheit and Centi...

Страница 17: ...ng Manual switch Fig 4 Fig 1 1 2 Fig 2 Sketch map for changing batteries 3 4 The batteries last about six months depending on how much you use the remote control unit Replace the batteries when the remote control unit s display fails to light or when the remote control cannot be used to change the air conditioner s settings When changing the batteries do not use the old or different batteries Use ...

Страница 18: ...ver the panel cover according to arrow direction and cover well Fig 6a 6b 5 1 Clean the Front Panel Make sure to take It off before cleaning 2 Washing Clean with a soft brush water and neutral detergent and then to dry it with a clean soft cloth Fig 5 Do not use hot water which temperature above 45 C to prevent fade or deformation NOTE 5 2 Cleaning the Air Filters Recommended once every 3 months 1...

Страница 19: ... dust adhering to the filters you can either use a vacuum cleaner or wash them with warm water the water with the neutral detergent should below 45 C when the filters are very dirty such asoil stain and dry it in the shade Fig 8a 5 2 Cleaning the Air Filters Continued 3 Put On Silver Ion Filters SAP K18AMS only Put on silver Ion filters make the side of filter with net facing you then cover the su...

Страница 20: ...ir filters see Pg 16 If the problem still has the unit required servicing Hence please contact with SANYO authorized maintenance center Sound of water flow can be heard during operation Sometimes there is swoosh or gurgle while the air conditioner is started stopped or when the compressor started or stopped running the sound is due to refrigerant flowing They are not malfunctions r e h g i h e r a...

Страница 21: ...sert well could resume normal operation Is the control in the receiving area Or is there obstruction Check if the voltage batteries in the control is enough if not change batteries If water leakage in indoor unit The air humidity is on the high side Condensing water over flowed The indoor unit drainage pipe connection loosed If water leakage in outdoor unit When the unit is running in COOL mode th...

Страница 22: ...very low to stop below the cool wind within 3 mins In HEAT mode when outdoor temp is very low or high humidity there are much frost on the outdoor heat exchanger unit will automatically defrost Indoor unit stop blowing fan 3 12 minutes During the de frosting there is water flowing out vapor be produced In dehumidifying mode indoor fan sometimes will stop in order to avoid condensing water be vapor...

Страница 23: ...n where the condensing water can be easily drained out and the places easily connected for outdoor unit 3 Select a location where the children can not reach 4 Can select the place where is strong enough to withstand the full weight and vibration of the unit And will not increase the noise 5 Be sure to leave enough space to allow access for routine maintenance The height of installed location shoul...

Страница 24: ...ect switch and air switch with enough capacity must be installed in the fixing circuit Air switch thermal magnetic breaker can protect the short circuit and overload The power supply position should be correctly connected and that should be reliably connected no internal short circuit Wrong connection may cause fire 1 Air conditioner is type 1 electric appliance thus please do conduct reliable ear...

Страница 25: ...ide Space to the wall Air inlet side The dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures A B A 550mm The Outdoor Unit Installation Dimension Models 250 cm Above 15cm Above 15cm Above 300cm Above 50cm Above 30cm Above 50cm Above 30cm Above 200cm Above 350mm SAP C18AM SAP C18AGH B Installation Service ...

Страница 26: ...th plastic granula 3 Be sure that the rear panel has been fixed firmly enough to support the weight of an adult of 60kg further more the weight should be evenly shared by each screw Ø55 Outdoor Indoor Wall pipe Seal pad Protection sleeve pipe Fig 13 Flooded Wrenched Bent Fig 14 Left tubing Right tubing Right rear tubing recommended Left rear tubing Fig 12 Fig 11 Wall Wall Mark on the middle of it ...

Страница 27: ...nfirm the rated voltage of the unit as shown in nameplate then carry out the wiring closely follow the wiring diagram 2 Provide a power outlet to be used exclusively for each unit with a power supply disconnect and circuit breaker for overcurrent protection provided in the exclusive line 3 To prevent possible hazard due to insulation failure the unit must be grounded 4 Each wiring connection must ...

Страница 28: ...ed and max allowable wire lengths and diameters for the power supply system Please refer to the wiring system diagram Fig 18 19 for the meaning of A B and C in Table 1 Fig 19 Heat Pump Model Grounding Line OUTDOOR UNIT INDOOR UNIT 2 Terminal 2 N L Terminal Power Supply Single Phase 220 240VAC 50HZ L N B A P C B Blue Black 4 N 5 N 4 5 Yellow Green Grounding Line Orange Violet C A Power supply wirin...

Страница 29: ... come staright down the wall to a point where water runoff won t stain the wall 5 Connect the refrigerant tubing to the outdoor unit After performing a leak test on the connecting part insulate it with the tubing insulation Fig 21 Also refer to Pg 29 connecting tubing between indoor and outdoor unit Indoor unit Floor level Wall Minimum height from floor level 2 5m Fig 23 9 5 How to Install the Ind...

Страница 30: ...red length for wiring Store excess wiring inside the cabinet 5 When connections are completed check that all connections are correct as shown in the wiring system diagram on the handle 6 Be sure to ground the unit according to your local codes 7 Install back the handle Screw x 1pc Fig 25 Heat Pump Model Handle Wireclamp Power Connection Wire Blue Black 4 5 Violet Orange Yellow Green Signal Wire Fi...

Страница 31: ...to mount it on the copper tube Make a flare at the end of copper tube with a flare tool Fig 27 Use GRID or equivalent A good flare should have the following charactcteristics inside surface is glossy and smooth edge is smooth tapered sides are of uniform length 10 2 3 Caution Before Connecting Tubes Tightly Be sure to apply a sealing cap or water proof tape to prevent dust or water from getting in...

Страница 32: ...of the outdoor to the top of tubing where it enters the wall As you wrap the tubing overlap half of each previous tape turn Fig 33 Clamp tubing bundle to wall using 1 clamp approx every 120cm Do not wind the armoring tape too tightly since this will decrease the heat insulation effect Also be sure the condensation drain hose splits away from the bundle and drips clear of the unit and the tubing 10...

Страница 33: ...or box wrench remove the valve caps from the service on both narrow and wide tubes 3 Connect a vacuum pump and a manifold valve with pressure gauges to the service port on the wide tube service valve Fig 35 Be sure to use a manifold valve for air purging If it is not available use a stop valve for this pupose The Hi knob of the manifold valve must always be kept closed 4 With the Lo knob of the ma...

Страница 34: ...hose connected to the wide tube service port slightly to release the pressure Then remove the hose This may cause the refrigerant gas to leak In order to avoid this take off the hose quickly 11 Fasten the valve cap on the wide tube service port securely with an adjustable wrench or box wrench Next mount the valve cap on the service valve and tightened it to 200 kg cm with a torque wrench This proc...

Страница 35: ...30 25 C18AGH 5 0 7 30 25 10 INSTALL OUTDOOR UNIT Installation Service Table 5 Packed in the outdoor unit Heat pump model only Parts Figure Q ty Parts Figure Q ty Tapping screw AAA alkaline battery 2 Remote control unit 1 Remote control holder Optional Part 1 Parts Figure Q ty Drain nozzle 1 Signal control wire Silver Ion filter 1 Putty 1 4 2 x 25 mm 2 1 Ins tube FAN OPER ONOFF C ON OFF FAN MODE CL...

Страница 36: ... port on the wide tube service valve Fig 39 2 Using a hex wrench turn the narrow tube service valve clockwise all the way to close the service valve Fig 40 Be sure to confirm that the wide tube service valve is fully open 3 Press the ON OFF button and start cooling operation 4 When the low pressure gauge reading falls from 1 to 0 5 kg cm2 fully close the wide tube valve stem Fig 41 Then quickly st...

Страница 37: ...t been fixed firmly The unit may drop shake or emit noise Have you done the refrigerant leakage test It may cause insufficient of cooling heating capacity Is heat insulation sufficient It may cause condensation and dripping Is water drainage well It may cause condensation and dripping Is the voltage in accordance with the rated voltage marked on the nameplate It may cause electric malfunction or d...