2-3. Other Component Specifications
8
4-way Valve (Solenoid coil)
LB64012 (Coil), V26-110B (Valve)
Coil rating
AC 220-240V, 50/60Hz, 6W
Coil resistance
Ω
(at 20°C)
2,000 ± 7%
Thermostat (Fan Speed Control 23S)
MQT5S
Switching temp.
°C
high
➞
LOW
28.5°C ± 1.5
low
➞
HIGH
31.5°C ± 2
Contact rating
AC 220V, 3A
Thermostat (Defrost thermo. 23D)
TRS02-12MSR
Operating temp.
°C
ON
12 ± 2
Diff.
8 deg. below
Starting Relay (SR)
AMVL300A
Coil rating
AC 300V, 50Hz
Coil resistance
k
Ω
(at 23°C)
13.3 ± 2%
Contact rating
20A AC
Operating voltage
AC 185 – 217V, 50Hz
Return voltage
AC 60 – 120V, 50Hz
Power Relay (PR)
G4F-1123T-US
Coil rating
DC 24V
Coil resistance
Ω
(at 20°C)
640 ± 10%
Contact rating
AC 240V, 20A
Outdoor Unit
SAP – C181AHA
SAP – C241AHA
Thermistor (Room sensor)
DTN-TKS142B
Resistance
k
Ω
25°C
5.0 ± 3%
Thermistor (Coil sensor)
DTN-TKS131B
Resistance
k
Ω
0°C
15.0 ± 2%
Transformer (TR)
ATR-J105
Rating
Primary
AC 230V, 50Hz
Secondary
19V, 0.526A
Capacity
10VA
Coil resistance
Ω
(at 21°C)
Primary (WHT – WHT):
205 ± 10%
Secondary (BRN – BRN):
2.0 ± 10%
Thermal cut-off temp.
150°C
Indoor Unit
SAP – K181AHA
SAP – K241AHA