8-7. Cold Draft Prevention (Heating)
●
This function controls indoor fan speed so a strong draft of cold air will not blow out before the indoor heat
exchange coil have sufficiently warmed up.
●
OPERATION lamp on front of the indoor unit flashes when this function is working.
●
Indoor fan operates in LL until indoor heat exchange coil temperature reaches 33°C.
●
In case of after releasing the defrosting, indoor fan halt its operation until the coil temperature reach 33°C.
●
When the coil temperature rises above 33°C, indoor fan operates in set speed.
The operation temperature shown as Tc in the chart above differ by models.
NOTE
OFF
Flashing
OFF
Set speed
Indoor fan
Operation lamp
Indoor heat exch.
coil temp. (
°
C)
33
25
Release of
cold draft prevention
LL
32
SAP-K92AH
SAP-K122AH
Tc
34
33