background image

INSTRUCTION MANUAL

Split System Air Conditioner

Wall-mounted type

Ceiling-mounted type

Recessed type

KS2432

TS2432

XS1822, XS1852

KS3032

TS3632

XS2432

KS3632

TS4232

XS3632

XS4232

COOL/FAN Model

Save These Instructions!

Pub. OI-85464189201002

©SANYO 2000

Содержание KS2432

Страница 1: ... System Air Conditioner Wall mounted type Ceiling mounted type Recessed type KS2432 TS2432 XS1822 XS1852 KS3032 TS3632 XS2432 KS3632 TS4232 XS3632 XS4232 COOL FAN Model Save These Instructions Pub OI 85464189201002 SANYO 2000 ...

Страница 2: ...omatic on off with time settings same time on off every day on timer and off timer 1 Hour OFF Timer This timer can be set to automatically turn off the unit at any time after one hour Night Setback Pressing this button changes the setting of the room temperature thermostat allowing you to set the temperature at whatever level that you find comfortable Automatic and 3 step Fan Speed Auto High Mediu...

Страница 3: ...3 Tips for Energy Saving 23 Operating Range 23 Product Information If you have problems or questions concerning your Air Conditioner you will need the following information Model and serial numbers are on the nameplate on the bottom of the cabinet Model No Serial No Date of purchase Dealer s address Phone number Alert Symbols The following symbols used in this manual alert you to potentially dange...

Страница 4: ...e 230 208 volts CAUTION Safety Instructions Read this Instruction Manual carefully before using this air conditioner If you still have any difficulties or problems consult your dealer for help This air conditioner is designed to give you comfortable room conditions Use this only for its intended purpose as described in this Instruction Manual Never touch the unit with wet hands Never use or store ...

Страница 5: ...airflow can be adjusted as desired using the remote control unit Remote control unit The wireless remote control unit controls power ON OFF operation mode selection temperature fan speed timer setting and air sweeping Refrigerant tubes The indoor and outdoor units are connected by copper tubes through which refrigerant gas flows Drain tube Moisture in the room is condensed and drains off by means ...

Страница 6: ...tor OPERATION lamp TIMER lamp Remote control receiver Recessed type Ceiling mounted type Air filter Recessed type Air intake grille Operation selector Ceiling mounted type Air intake grille Finger hold Operation selector 6 OI 201 06EG ...

Страница 7: ...n if you are not going to use the air conditioner for a few days or longer The OFF position does not disconnect the power Use the main power switch to turn off power completely TEST position This position is used only when servicing the air conditioner CAUTION Do not set at the TEST position for normal operation OPERATION lamp This lights when the system is in the continuous COOL or FAN mode TIMER...

Страница 8: ...s shown Displayed when the temperature setting is at the upper or lower allowable limit Displayed when setting timer F OFF HR 1 Symbols Displayed when main unit sensor is in use 3 Set temperature 60 88 F When set to 82 F Current temperature indication 4 Timer 24 hour clock with ON OFF Program Timer 24 hour ON Timer 24 hour OFF Timer 1 hour OFF Timer 5 NIGHT SETBACK 6 Confirmation of transmission 7...

Страница 9: ...t temperature to save energy TEMP setting buttons Press the button to increase the set temperature Press the button to reduce the set temperature ON OFF operation button This button is for turning the air conditioner on and off Timer setting buttons First press the PROGRAM button to select the mode you want Each time you press the HH button the hours advance by one Each time you press the MM butto...

Страница 10: ...r conditioner starts at the set time The air conditioner stops and starts or starts and stops at the set times every day MODE selector button COOL FAN Use this button to select COOL or FAN mode The air conditioner makes the room cooler The air conditioner works only as a circulation fan FLAP button Press this button to select the sweep function which moves the flap up and down automatically The fl...

Страница 11: ...han 1 month take out the batteries How to Use the Remote Control Unit When using the remote control unit always point the unit s transmitter head directly at the air conditioner s receiver Remote Control Unit Installation Position The remote control unit may be operated either from a non fixed position or from a wall mounted position To ensure that the air conditioner operates correctly DO NOT ins...

Страница 12: ...nting 1 Momentarily hold the remote control unit at the desired mounting position 2 Confirm that the air conditioner responds correctly when you press keys on the remote control from that position 3 After confirming correct operation use a screwdriver to screw the mounting screw into the wall 4 Remove the batteries of the remote control unit 5 Use a screwdriver to screw the remote control unit sec...

Страница 13: ... temperature Adjustable temperature range 88 F max 60 F min STEP 4 Set the FAN SPEED selector button to the setting you want NOTE If the fan speed is set to Automatic the fan speed switches automatically according to the difference between the actual room temperature and the temperature setting STEP 5 Press the FLAP button and set the airflow direction as desired Refer to Adjusting the Airflow Dir...

Страница 14: ...re and the set temperature is detected by the microcomputer which then automatically switches the fan speed to the most suitable level Cooling mode When difference between room temperature and set temperature is FAN SPEED 4 F and over High Between 4 F and 2 F Medium Below 2 F Low NOTE The above table assumes that the sensor on the remote control is being used If the sensor on the indoor unit is be...

Страница 15: ...P FAN SPEED HH TIMER SELECT MM NIGHT SETBACK OFF ON CLOCK AIR CONDITIONER HR 1 A PM F When the night setback mode is selected the air conditioner automatically raises the temperature setting 2 F when 30 minutes have passed after the selection was made and then another 2 F after another 30 minutes have passed regardless of the indoor temperature when night setback was selected This enables you to s...

Страница 16: ...f power failure the unit will stop When the power is resumed the unit will restart automatically after three minutes Remote Control Unit The remote control unit sends the setting condition to the air conditioner regularly at three minute intervals 16 OI 201 16EG ...

Страница 17: ...ime indication alone flashes 2 Press the HH button until PM 9 is displayed Press the MM button until 10 is displayed The display will auto matically stop flashing except for the symbol after 10 sec OFF PM 1 Press the Program button OFF ON CLOCK once The timer OFF and time indications flash 2 Press the HH button until PM 11 is displayed Press the MM button until 30 is displayed The display will cha...

Страница 18: ...on Indication 1 Press the Program button OFF ON CLOCK twice The timer ON and time indications flash 2 Press the HH button until AM 7 is displayed Press the MM button until 10 is displayed The display will change automatically back to show the present time after 10 sec 3 Press the TIMER SELECT button three times to set ON time The present time and ON are displayed 4 Press the ON OFF button to start...

Страница 19: ...eration button again The 1 Hour Timer function is now cancelled and the unit operates normally NOTE If while the 1 Hour Timer function is operating the 1 HR TIMER button is pressed once to cancel the function and then again the unit continues to operate for one hour from that point in time and then stops 2 Operation Together with the Program Timer The Program Timer and 1 Hour OFF Timer may be used...

Страница 20: ...cooling CAUTION Do not move the flap with your hands Operation without the Remote Control Unit If you have lost the remote control unit or it has trouble follow the steps below 1 When the air conditioner is stopped If you want to turn on the air conditioner switch the operation selector to the OFF position and then to the ON position NOTE The set temperature and fan speed are automatically set at ...

Страница 21: ...e cleaned every year Consult your dealer or service center Air filter The air filter collects dust and other particles from the air and should be cleaned about once every six months Recessed type or two weeks ceiling mounted type and wall mounted type If the filter gets blocked the efficiency of the air conditioner drops greatly NOTE The frequency with which the filter should be cleaned depends on...

Страница 22: ... Unit CAUTION 1 Certain metal edges and the condenser fins are sharp and may cause injury if handled improperly special care should be taken when you clean these parts 2 Periodically check the outdoor unit to see if the air outlet or air intake is clogged with dirt or soot 3 The internal coil and other components of the outdoor unit must also be cleaned periodically Consult your dealer or service ...

Страница 23: ...rge port 4 Remove it to ensure good air flow 5 Thermostat is set too high 5 Set the temperature lower Tips for Energy Saving Do not Block the air intake and outlet of the unit If either is obstructed the unit will not work well and may be damaged Let direct sunlight into the room Use sunshades blinds or curtains If the walls and ceiling of the room are warmed by the sun it will take longer to cool...

Страница 24: ...SANYO FISHER COMPANY A DIVISION OF SANYO NORTH AMERICA CORPORATION 21605 Plummer Street Chatsworth CA 91311 U S A In Canada SANYO Canada Inc 50 Beth Nealson Drive Toronto Ontario M4H 1M6 Canada ...

Отзывы: