CM1972 (3-room multi unit)
CM2472 (4-room multi unit)
CM3172 (4-room multi unit)

CLM1972 (3-room multi unit)
CLM2472 (4-room multi unit)
CLM3172 (4-room multi unit)

< Applicable Multi-Outdoor Units >

TECHNICAL & SERVICE MANUAL

INDOOR UNIT : KMS0772

KMS0972
KMS1272
KMS1872
KMS2472

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

FILE NO.

Destination: North America

Wall Mounted Type Indoor Unit

KMS0772
KMS0972
KMS1272

KMS1872
KMS2472

REFERENCE NO. 

SM

700665-02

Product Code No.

1 852 099 87

1 852 099 88

1 852 099 89

1 852 099 90

1 852 099 91

Capacity

7,500BTU / h

9,000BTU / h

11,900BTU / h

17,500BTU / h

24,200BTU / h

Indoor Model No.

KMS0772

KMS0972

KMS1272

KMS1872

KMS2472

NOTE

AIR CONDITIONER

AIR CONDITIONER

IMPORTANT

These air conditioners employ new
refrigerant R410A.

Pay special attention when
servicing the unit.

For details about the combinations, refer to 

Unit Combination Table  in the 

T. Service 

Manual

 for the Multi Outdoor Units.

Содержание KMS0772

Страница 1: ... Type Indoor Unit KMS0772 KMS0972 KMS1272 KMS1872 KMS2472 REFERENCE NO SM700665 02 Product Code No 1 852 099 87 1 852 099 88 1 852 099 89 1 852 099 90 1 852 099 91 Capacity 7 500BTU h 9 000BTU h 11 900BTU h 17 500BTU h 24 200BTU h Indoor Model No KMS0772 KMS0972 KMS1272 KMS1872 KMS2472 NOTE AIR CONDITIONER AIR CONDITIONER IMPORTANT These air conditioners employ new refrigerant R410A Pay special at...

Страница 2: ...e fire hazard When Transporting Be careful when picking up and moving the indoor and outdoor units Get a partner to help and bend your knees when lifting to reduce strain on your back Sharp edges or thin aluminum fins on the air conditioner can cut your fingers When Installing In a Ceiling or Wall Make sure the ceiling wall is strong enough to hold the unit s weight It may be necessary to construc...

Страница 3: ... Distance Charts 6 ELECTRICAL DATA 6 1 Electric Wiring Diagrams 7 FUNCTIONS 7 1 Operation Functions 7 2 Protective Functions 8 TROUBLESHOOTING 8 1 Precautions before Performing Inspection or Repair 8 2 Method of Self Diagnostics 8 3 Checking the Indoor and Outdoor Units 8 4 Trouble Diagnosis of Fan Motor 8 5 Noise Malfunction and Electromagnetic Interference APPENDIX A INSTRUCTION MANUAL APPENDIX ...

Страница 4: ...2 KMS1872 KMS2472 3 Room CM1972 YES YES YES YES NO 4 Room CM2472 YES YES YES YES YES 4 Room CM3172 YES YES YES YES YES 3 Room CLM1972 YES YES YES YES NO 4 Room CLM2472 YES YES YES YES YES 4 Room CLM3172 YES YES YES YES YES Indoor Unit Multi Outdoor Unit 4 ...

Страница 5: ...ion with cooling outdoor unit CM1972 CM2472 or CM3172 95 F D B 71 F W B 67 F D B 57 F W B Maximum Minimum 115 F D B 1 Temperature Indoor Air Intake Temp Outdoor Air Intake Temp Cooling Combination with low ambient cooling outdoor unit CLM1972 CLM2472 or CM3172 1 32 F D B When combined with KMS1872 or KMS2472 23 F D B When combined with KMS0772 KMS0972 or KMS1272 5 ...

Страница 6: ...lectrical Rating Available Voltage Range 2 77 Cooling Indoor Fan Speeds Features Control Temperature Control Timer Control Unit Airflow Direction Indoor Horizontal Vertical 3 8 9 52 inch mm Refrigerant Tubing Connections R410A Qt Quiet mode dB A Indoor Hi Me Lo Qt 33 30 27 23 Auto Washable Anti Mold Air Filter Refrigerant cu ft m3 Operation Sound Refrigerant Tube Diameter inch mm inch mm inch mm D...

Страница 7: ...m Refrigerant Tubing Connections R410A Qt Quiet mode dB A Indoor Hi Me Lo Qt 33 30 27 23 Airflow Direction Indoor Horizontal Vertical Indoor Fan Speeds Features Control Temperature Control Timer Control Unit Moisture Removal High 187 to 253 Electrical Rating Available Voltage Range 2 77 Cooling Optional Air Clean Filter Air Circulation High ft3 min m3 h W Power Input V A Refrigerant Tubing Kit Acc...

Страница 8: ...Available Voltage Range 3 4 Cooling Indoor Fan Speeds Features Control Temperature Control Timer Control Unit Airflow Direction Indoor Horizontal Vertical 3 8 9 52 inch mm Refrigerant Tubing Connections R410A Qt Quiet mode dB A Indoor Hi Me Lo Qt 34 31 28 23 Auto Washable Anti Mold Air Filter Refrigerant cu ft m3 Operation Sound Refrigerant Tube Diameter inch mm inch mm inch mm Dimensions Weight D...

Страница 9: ...g Available Voltage Range 3 4 Cooling Indoor Fan Speeds Features Control Temperature Control Timer Control Unit Airflow Direction Indoor Horizontal Vertical 3 8 9 52 inch mm Refrigerant Tubing Connections R410A Qt Quiet mode dB A Indoor Hi Me Lo Qt 34 31 28 23 Auto Washable Anti Mold Air Filter Refrigerant cu ft m3 Operation Sound Refrigerant Tube Diameter inch mm inch mm inch mm Dimensions Weight...

Страница 10: ... Available Voltage Range 4 26 Cooling Indoor Fan Speeds Features Control Temperature Control Timer Control Unit Airflow Direction Indoor Horizontal Vertical 3 8 9 52 inch mm Refrigerant Tubing Connections R410A Qt Quiet mode dB A Indoor Hi Me Lo Qt 36 33 29 25 Auto Washable Anti Mold Air Filter Refrigerant cu ft m3 Operation Sound Refrigerant Tube Diameter inch mm inch mm inch mm Dimensions Weight...

Страница 11: ...mm Refrigerant Tubing Connections R410A Qt Quiet mode dB A Indoor Hi Me Lo Qt 36 33 29 25 Airflow Direction Indoor Horizontal Vertical Indoor Fan Speeds Features Control Temperature Control Timer Control Unit Moisture Removal High 187 to 253 Electrical Rating Available Voltage Range 4 26 Cooling Optional Air Clean Filter Air Circulation High ft3 min m3 h W Power Input V A Refrigerant Tubing Kit Ac...

Страница 12: ...m Refrigerant Tubing Connections R410A Qt Quiet mode dB A Indoor Hi Me Lo Qt 41 38 34 28 Airflow Direction Indoor Horizontal Vertical Indoor Fan Speeds Features Control Temperature Control Timer Control Unit Moisture Removal High 187 to 253 Electrical Rating Available Voltage Range 4 89 Cooling Optional Air Clean Filter Air Circulation High ft3 min m3 h W Power Input V A Refrigerant Tubing Kit Acc...

Страница 13: ...ng Available Voltage Range 4 89 Cooling Indoor Fan Speeds Features Control Temperature Control Timer Control Unit Airflow Direction Indoor Horizontal Vertical 1 2 12 7 inch mm Refrigerant Tubing Connections R410A Qt Quiet mode dB A Indoor Hi Me Lo Qt 41 38 34 28 Auto Washable Anti Mold Air Filter Refrigerant cu ft m3 Operation Sound Refrigerant Tube Diameter inch mm inch mm inch mm Dimensions Weig...

Страница 14: ...m Refrigerant Tubing Connections R410A Qt Quiet mode dB A Indoor Hi Me Lo Qt 44 41 38 30 Airflow Direction Indoor Horizontal Vertical Indoor Fan Speeds Features Control Temperature Control Timer Control Unit Moisture Removal High 187 to 253 Electrical Rating Available Voltage Range 4 89 Cooling Optional Air Clean Filter Air Circulation High ft3 min m3 h W Power Input V A Refrigerant Tubing Kit Acc...

Страница 15: ...g Available Voltage Range 4 89 Cooling Indoor Fan Speeds Features Control Temperature Control Timer Control Unit Airflow Direction Indoor Horizontal Vertical 5 8 15 88 inch mm Refrigerant Tubing Connections R410A Qt Quiet mode dB A Indoor Hi Me Lo Qt 44 41 38 30 Auto Washable Anti Mold Air Filter Refrigerant cu ft m3 Operation Sound Refrigerant Tube Diameter inch mm inch mm inch mm Dimensions Weig...

Страница 16: ...CS 4VPIS4U 1 D3 11 16 L24 31 32 D94 L634 Fan Motor Heat Exchanger Coil Run Capacitor W Ohm Ambient Temp 68 o F 20 o C Yes Nominal Output Coil Resistance Ambient Temp 77 o F 25 o C DATASUBJECTTOCHANGE WITHOUTNOTICE Aluminum Plate Fin Copper Tube 2 19 5 Flap Motor Type Model Rating Face Area ft2 m2 2 02 0 188 Coil Rows Fins per inch Internal Controller Yes Coil Resistance Ohm Stepping Motor MP24Z3 D...

Страница 17: ...1 32 D94 L634 Fan Motor Heat Exchanger Coil Run Capacitor W Ohm Ambient Temp 68 o F 20 o C Yes Nominal Output Coil Resistance Ambient Temp 77 o F 25 o C DATASUBJECTTOCHANGE WITHOUTNOTICE Aluminum Plate Fin Copper Tube 2 19 5 Flap Motor Type Model Rating Face Area ft2 m2 2 02 0 188 Coil Rows Fins per inch Internal Controller Yes Coil Resistance Ohm Stepping Motor MP24Z3 DC 12V Each Pair of Terminal...

Страница 18: ...1 32 D94 L634 Fan Motor Heat Exchanger Coil Run Capacitor W Ohm Ambient Temp 68 o F 20 o C Yes Nominal Output Coil Resistance Ambient Temp 77 o F 25 o C DATASUBJECTTOCHANGE WITHOUTNOTICE Aluminum Plate Fin Copper Tube 2 19 5 Flap Motor Type Model Rating Face Area ft2 m2 2 02 0 188 Coil Rows Fins per inch Internal Controller Yes Coil Resistance Ohm Stepping Motor MP24Z3 DC 12V Each Pair of Terminal...

Страница 19: ...9 32 D94 L845 Fan Motor Heat Exchanger Coil Run Capacitor W Ohm Ambient Temp 68 o F 20 o C Yes Nominal Output Coil Resistance Ambient Temp 77 o F 25 o C DATASUBJECTTOCHANGE WITHOUTNOTICE Aluminum Plate Fin Copper Tube 2 19 5 Flap Motor Type Model Rating Face Area ft2 m2 3 07 0 285 Coil Rows Fins per inch Internal Controller Yes Coil Resistance Ohm Stepping Motor MP24Z3 DC 12V Each Pair of Terminal...

Страница 20: ...9 32 D94 L845 Fan Motor Heat Exchanger Coil Run Capacitor W Ohm Ambient Temp 68 o F 20 o C Yes Nominal Output Coil Resistance Ambient Temp 77 o F 25 o C DATASUBJECTTOCHANGE WITHOUTNOTICE Aluminum Plate Fin Copper Tube 2 19 5 Flap Motor Type Model Rating Face Area ft2 m2 3 07 0 285 Coil Rows Fins per inch Internal Controller Yes Coil Resistance Ohm Stepping Motor MP24Z3 DC 12V Each Pair of Terminal...

Страница 21: ...0772 KMS0972 KMS1272 KMS1872 KMS2472 Indoor heat exchanger sensor PTM D51H S3 TH1 Model No of sensor Sensor Name 1 1 1 Quantity of Sensor 0 0 PTM D51H S3 2 TH1 0 0 0 1 1 0 32 50 68 86 104 122 140 158 176 194 0 10 20 30 40 50 60 70 80 90 40 60 80 100 120 140 160 180 200 20 50 1 0 2 3 4 5 6 7 8 9 10 59 68 77 86 95 104 10 15 20 25 30 35 40 Resistance k ohm Resistance k ohm Temperature F C Temperature...

Страница 22: ...3 DIMENSIONAL DATA Indoor Unit KMS0772 KMS0972 KMS1272 Unit inch mm 22 ...

Страница 23: ... 8 2 3 8 2 3 8 1 15 16 31 32 15 27 32 3 3 4 17 23 32 3 3 4 8 3 8 4 5 8 4 5 8 41 15 16 11 23 32 1 25 32 Drain hose dia 23 32 18 Narrow tube dia 1 4 6 35 3 9 16 3 9 16 12 3 32 17 23 32 12 3 32 3 3 4 1 25 32 3 3 4 7 31 32 7 31 32 d i a 3 5 3 2 d i a 3 5 3 2 7 23 32 1 27 32 1 3 32 2 3 4 1 1 4 1 1 4 5 9 32 2 1 16 29 32 Wide tube dia 1 2 12 70 KMS1872 dia 5 8 15 88 KMS2472 Indoor Unit KMS1872 KMS2472 23...

Страница 24: ...4 6 35 mm 4 REFRIGERANT FLOW DIAGRAM 4 1 Refrigerant Flow Diagram Indoor Unit KMS0772 KMS0972 KMS1272 Indoor Unit KMS1872 Indoor Unit KMS2472 Indoor heat exchanger Cooling cycle Indoor unit Indoor heat exchanger Cooling cycle Indoor unit Indoor heat exchanger Cooling cycle Indoor unit 24 ...

Страница 25: ...t sec Vertical distance ft Room air temp 80 F 26 7 C Fan speed High Cooling Flap angle 0 Axis air velocity 0 Flap angle 30 Axis air velocity 30 5 PERFORMANCE DATA 5 1 Air Throw Distance Charts Indoor Unit KMS0772 25 0 5 10 15 0 5 10 15 20 25 30 ...

Страница 26: ...e ft Axis air velocity ft sec Vertical distance ft Cooling Flap angle 0 Axis air velocity 0 Flap angle 30 Axis air velocity 30 Indoor Unit KMS0972 Room air temp 80 F 26 7 C Fan speed High 26 0 5 10 15 0 5 10 15 20 25 30 ...

Страница 27: ...e ft Axis air velocity ft sec Vertical distance ft Room air temp 80 F 26 7 C Fan speed High Cooling Flap angle 0 Axis air velocity 0 Flap angle 30 Axis air velocity 30 Indoor Unit KMS1272 27 0 5 10 15 0 5 10 15 20 25 30 ...

Страница 28: ...e ft Axis air velocity ft sec Vertical distance ft Room air temp 80 F 26 7 C Fan speed High Cooling Flap angle 0 Axis air velocity 0 Flap angle 30 Axis air velocity 30 Indoor Unit KMS1872 28 0 5 10 15 0 5 10 15 20 25 30 ...

Страница 29: ...e ft Axis air velocity ft sec Vertical distance ft Room air temp 80 F 26 7 C Fan speed High Cooling Flap angle 0 Axis air velocity 0 Flap angle 30 Axis air velocity 30 Indoor Unit KMS2472 29 0 5 10 15 0 5 10 15 20 25 30 ...

Страница 30: ...SY ROOM COIL 4P WHT DCM 6P BLU CONTROLLER FM FAN MOTOR ROOM THERMISTOR BLK BLK BLK WHT RED BLK BLK 1 2 3 4 1 2 3 4 COIL THERMISTOR ION 3P WHT HA JEM A 1 2 3 1 2 3 1 2 3 1 2 3 4P WHT 1 2 4 BLK 3 BLK BLK RED WHT 1 2 3 4 1 2 3 4 ION ASSY ION TERMINAL 1 2 3 WHT BLK RED RED CONNECTOR 8FA2 5257 69700 0 BLU WHT BLK YEL WARNING To avoid electrical shock hazard be sure to disconnect power before checking s...

Страница 31: ... 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 IND LAMP ASSY ROOM COIL 4P WHT DCM 6P BLU CONTROLLER FM FAN MOTOR ROOM THERMISTOR BLK BLK BLK BLK 1 2 3 4 1 2 3 4 COIL THERMISTOR ION 3P WHT HA JEM A 1 2 3 1 2 3 4P WHT 1 2 4 BLK 3 BLK BLK RED WHT 1 2 3 4 1 2 3 4 ION ASSY ION TERMINAL 1 2 3 WHT BLK RED RED BLU WHT BLK YEL Indoor Unit KMS1872 KMS2472 WARNING To avoid electrical shock hazard be sur...

Страница 32: ...3 C below the set temperature When the monitoring range is entered the compressor stops and the indoor fan operates with 1 f fluctuation DRY A DRY B Monitor Conditions are monitored at all times when the room temperature is below 59 F 15 C Load COOL zone A zone B zone Emergency operation is available when the remote controller malfunctions has been lost or otherwise cannot be used The set temperat...

Страница 33: ...by use of ON timer operation Frequency MAX 0 Start End Time 30 min 5 min Setting temperature Press the NIGHT SETBACK button When NIGHT SETBACK operation is set the temperature and fan speed settings will be adjusted automatically to allow comfortable sleep When NIGHT SETBACK operation is set mark appears on the remote controller The main unit display lamp also becomes dimmer COOL and DRY modes Whe...

Страница 34: ...bited d When the temperature reaches Point C or above freezing prevention is ended and control is the same as in the a area When the temperature drops to below 36 F 2 C continuously for 2 minutes or longer the compressor stops Once the freeze condition is detected the air conditioner will work less than the maximum frequency until it is turned off The Freeze Prevention Control during the Low Ambie...

Страница 35: ... below to perform detailed trouble diagnostics Step 1 Press and hold the remote controller ION button and 1 HR TIMER button At the same time press the ACL reset button Use a pointed object such as the tip of a pen to press the ACL button When this has been done oP 1 test run appears blinking in the remote controller clock display area Step 2 Next press the 1 HR TIMER button once to change the disp...

Страница 36: ...board failure 1 Sensor open circuit or short circuit 2 Contact failure at connector or open circuit at terminal crimping location 3 Outdoor circuit board failure Outdoor circuit board failure 1 Mis wiring 2 AC power failure 3 Blown fuse 4 Power relay failure 5 Indoor or outdoor circuit board failure 1 HIC or power Tr failure 2 Outdoor fan does not turn 3 Instantaneous power outage 4 Service valve ...

Страница 37: ... function fails to operate Check the indoor unit Is the fuse blown Replace the controller Replace the circuit board or the fuse No indicators illuminate and the indoor fan does not rotate Check the power voltage Normal Blown 37 ...

Страница 38: ...ls L1 and L2 If there are no problems with the above then check the indoor unit Turn the power OFF before performing short circuiting procedures Refer to the previous pages when performing system self diagnostics So that the check can be made quickly indicators blink at first communication after power ON Before performing the above checks perform TEST run operation and check that the rated voltage...

Страница 39: ...d Trouble symptom 1 The fan does not stop when the unit stops Indoor unit controller trouble Trouble symptom 2 The fan motor does not rotate when the unit is operating Diagnostic procedure Disconnect the motor connectors and measure the voltage at the DC motor connectors on the indoor unit controller 3 locations Diagnostic results All of the above measured values are normal Fan motor trouble Repla...

Страница 40: ... the system less susceptible to noise Insulate for noise or distance from the noise source Trouble Either of the following trouble may occur 1 The unit may stop suddenly during operation 2 Indicator lamps may flicker 2 Electromagnetic interference This refers to noise generated by high speed switching of the microcomputer and compressor This noise radiates through space and returns to the electric...

Страница 41: ...INSTRUCTION MANUAL KMS0772 KMS0972 KMS1272 KMS1872 KMS2472 OI 852 6 4180 806 00 1 OI 852 6 4180 807 00 1 APPENDIX A A 1 ...

Страница 42: ...able Automatic and 3 step Fan Speed Auto High Medium Low Air Sweep Control This function moves a flap up and down in the air outlet directing air in a sweeping motion around the room and providing comfort in every corner Auto Flap Control This automatically sets the flap to the optimum position during cooling and drying operation Automatic Restart Function for Power Failure Even when power failure...

Страница 43: ...ct Information If you have problems or questions concerning your Air Conditioner you will need the following information Model and serial numbers are on the nameplate on the bottom of the cabinet Model No ______________________ Serial No ____________________ Date of purchase ________________________________________________ Dealer s address ________________________________________________ Phone num...

Страница 44: ... not install this air conditioner where there are fumes or flammable gases or in an extremely humid space such as a greenhouse Do not install the air conditioner where excessively high heat generating objects are placed Avoid To protect the air conditioner from heavy corrosion avoid installing the outdoor unit where salty sea water can splash directly onto it or in sulphurous air near a spa Never ...

Страница 45: ...lown out of the air conditioner through the air outlet Remote Control Unit The wireless remote control unit controls power ON OFF operation mode selection temperature fan speed timer setting and air sweeping Refrigerant Tubes The indoor and outdoor units are connected by copper tubes through which refrigerant gas flows Drain Hose Moisture in the room condenses and drains off through this hose Outd...

Страница 46: ...em is being controlled by the timer QUIET lamp This lamp lights during operation in the QUIET mode ION lamp This lamp lights during operation in the ION mode while the indoor unit is operating The unit s display lamps are dimmed during operation in the NIGHT SETBACK mode QUIET REMOTE CONTROL receiver Avoid using radio equipment such as mobile phone near within 4 ft the remote control receiver Some...

Страница 47: ...OFF Timer 1 hour OFF Timer 5 NIGHT SETBACK 6 Confirmation of transmission 7 Auto fla dication Flap angle indication Sweep indication 8 High power operation 9 Quiet operation 10 ION operation Displayed when setting timer Displayed when transmitting data Displayed when indoor unit sensor is in use Displayed when setting temperature Displayed when temperature is shown Displayed when the time display ...

Страница 48: ...negative ions generated during operation on and off ON OFF operation button This button is for turning the air conditioner on and off 1 HR TIMER button 1 HOUR OFF TIMER When you press this button regardless of whether the unit is operating or stopping the unit operates for one hour and then shuts down Transmitter Sensor Cover closed Display FAN SPEED selector button FLAP button ON TIME setting but...

Страница 49: ...nit will automatically adjust the set temperature to save energy FLAP button Press this button either to select the setting of the airflow direction to the auto flap in each mode or one of the six possible positions manually or to select the sweep function which moves the flap up and down automatically Auto flap setting If selected in a cooling or dry operation the flap is set at position 7 in the...

Страница 50: ... not be bent The remote control unit sends the temperature signal to the air conditioner regularly at five minute intervals If the signal from the remote control unit stops for more than 15 minutes due to the loss of the remote control unit or other trouble the air conditioner will switch to the temperature sensor which is built into the indoor unit and control the room temperature In these cases ...

Страница 51: ... remote control unit every 5 minutes Mounting the Remote Control Unit Before mounting the remote control unit press the ON OFF operation button at the mounting location to make sure that the air conditioner operates from that location The indoor unit should make a beeping sound to indicate that it has received the signal To take out the remote control unit pull it forward When Holding the Remote C...

Страница 52: ...P 2 To start the air conditioner press the ON OFF operation button STEP 3 Press the TEMP setting buttons to change the temperature setting to the desired temperature Adjustable temperature range STEP 4 Set the FAN SPEED selector button to the setting you want STEP 5 Press the FLAP button and set the airflow direction as desired Refer to Adjusting the Airflow Direction on page 20 To stop the air co...

Страница 53: ...the event of power failure the unit will stop 2 Adjusting the Fan Speed A Automatic fan speed Simply set the FAN SPEED selector button to the position This automatically sets the best fan speed for the room temperature B Manual fan speed If you want to adjust fan speed manually during operation just set the FAN SPEED selector button as desired or 3 Fan Only If you want to circulate air without any...

Страница 54: ...When the night setback mode is selected the air conditioner automatically raises the temperature setting 2 F when 30 minutes have passed after the selection was made and then another 2 F after another 30 minutes have passed regardless of the indoor temperature when night setback was selected This enables you to save energy without sacrificing comfort This function is convenient when gentle cooling...

Страница 55: ...the display To cancel press HIGH POWER button again When the HIGH POWER button is pressed the unit operates at maximum output for 30 minutes regardless of the desired temperature The fan speed is 1 step above High QUIET Mode and HIGH POWER Mode cannot be used at the same time 7 ION Mode The ION mode is used during operation to generate negative ions that freshen up the air in the room Press the IO...

Страница 56: ...ected from ice or frost when combined with the outdoor unit for Low Ambient Cooling models In the event of power failure the unit will stop When the power is resumed the unit will restart automatically within 15 minutes by the remote control unit Clicking sound is heard from the air conditioner In cooling operation any plastic parts may shrink due to a sudden temperature change In this event a cli...

Страница 57: ...Return button until PM 10 30 is displayed The time can be set in 1 minute increments Holding down the button advances the time rapidly in 10 minute increments 3 Press the CLOCK button again This completes the setting of the current time 1 Press the OFF TIME setting button once The timer indication is displayed and the present OFF time is shown 2 Press the Advance Return button until AM 11 00 is di...

Страница 58: ... operates as if it is turned off Operation Indication 1 Press the ON TIME setting button once The timer indication is displayed and the present ON time is shown 2 Press the Advance Return button until AM 7 10 is displayed The timer indication blinks The time can be set in 10 minute increments Holding down the button advances the time rapidly in 10 minute increments 3 Wait a few seconds and then th...

Страница 59: ...to operate for one hour from that point in time and then stops It is not possible to use the OFF Timer and 1 Hour OFF Timer together Whichever function is set last takes precedence If the 1 HR TIMER button is pressed while the TIMER OFF function operates the OFF Timer is cancelled and the unit will stop operating one hour later 2 Operation together with the DAILY ON OFF REPEAT Timer The 1 Hour OFF...

Страница 60: ...flap automatically closes when the unit is off Use the FLAP button on the remote control to adjust the position of the flap If you move the flap by hand the flap position according to the remote control and the actual flap position may no longer match If this should happen shut off the unit wait for the flap to close and then turn on the unit again the flap position will now be normal again Do not...

Страница 61: ...components and cause an electric shock hazard Casing and Grille Indoor Unit Clean the casing and grille of the indoor unit with a vacuum cleaner brush or wipe them with a clean soft cloth If these parts are stained use a clean cloth moistened with a mild liquid detergent When cleaning the grille be careful not to force the vanes out of place 1 Never use solvents or harsh chemicals when cleaning th...

Страница 62: ... the anti mold filter 1 With the FRONT mark of the anti mold filter at the front align the two indentions near the mark with the hooks at the rear of the air intake grille and then mount the anti mold filter 2 Allow the edge of the air intake grille to slide into the top of the indoor unit and then insert it all the way inside 3 To attach the air intake grille to the indoor unit press its bottom r...

Страница 63: ...e stubborn dirt moisten a cloth in warm water no hotter than 104 F wring thoroughly and then wipe The air intake grille can be removed in order to wash it with water Removing and remounting the air intake grille Refer to How to remove the anti mold filter and How to replace the anti mold filter on page 22 When using a footstool or the like be careful not to let it tip over Washing the grille with ...

Страница 64: ...ter to improve airflow 2 Heat source or many people in room 2 Eliminate heat source if possible 3 Doors and or windows are open 3 Shut them to keep the heat out 4 Obstacle near air intake or air discharge port 4 Remove it to ensure good airflow 5 Thermostat is set too high for cooling 5 Set the temperature lower Clicking sound is heard from the air conditioner In cooling operation any plastic part...

Страница 65: ...INSTALLATION INSTRUCTIONS KMS0772 KMS0972 KMS1272 KMS1872 KMS2472 II 852 6 4189 996 00 0 APPENDIX B A 2 ...

Страница 66: ...ials Required for Installation 2 INSTALLATION SITE SELECTION 4 2 1 Indoor Unit 2 2 Embedding the Tubing and Wiring 3 HOW TO INSTALL THE INDOOR UNIT 6 3 1 Remove the Rear Panel from the Unit 3 2 Make a Hole 3 3 Install the Rear Panel on the Wall 3 4 Remove the Grille to Install the Indoor Unit 3 5 Shape the Indoor Side Tubing 3 6 Wiring Instructions 3 7 Wiring Instructions for Inter unit Connection...

Страница 67: ...en picking up and moving the indoor and out door units Get a partner to help and bend your knees when lifting to reduce strain on your back Sharp edges or thin alu minum fins on the air conditioner can cut your fingers When Installing In a Ceiling or Wall Make sure the ceiling wall is strong enough to hold the unit s weight It may be necessary to construct a strong wood or metal frame to provide a...

Страница 68: ... refrigerant tub ing as detailed in Table 2 Cut each tube to the appropriate lengths 1 to 1 4 30 cm to 40 cm to dampen vibration between units Table 2 2 Foamed polyethylene insulation for the specified copper tubes as required to precise length of tubing Wall thickness of the insulation should be not less than 5 16 8 mm 3 Use insulated copper wire for field wiring Wire size varies with the total l...

Страница 69: ...tion that will hold the weight of the unit G select a location where tubing and drain hose have the shortest run to the outside Fig 1 G allow room for operation and maintenance as well as unrestricted air flow around the unit Fig 2 G install the unit within the maximum elevation difference H1 H2 H3 H4 above or below the outdoor unit and within a total tubing length L1 L2 L3 L1 L2 L3 L4 from the ou...

Страница 70: ...ft open for an extended time moisture in the air inside the tubing may condense into water droplets and lead to water contamination of the refrig erant circuit G In order to prevent insulation breakdown and ground faults do not allow wiring ends to come in contact with rainwater or be subjected to condensation or dew G Apply sufficient thermal insulation to the refrigerant tubing and drain pipes T...

Страница 71: ... Make a Hole 1 Place the rear panel from the indoor unit on the wall at the location selected Make sure the panel is hori zontal using a carpenter s level or tape measure to measure down from the ceiling Wait until after cut ting the hole before attaching the rear panel to the wall 2 Determine which side of the unit you should make the hole for tubing and wiring Fig 9a or 9b In the case of left re...

Страница 72: ...em a or b below depending on the wall type a If Wooden Wall 1 Attach the rear panel to the wall with the 8 screws provided Fig 13a or 13b If you are not able to line up the holes in the rear panel with the beam locations marked on the wall use rawl plugs or toggle bolts to go through the holes on the panel or drill 3 16 5 mm dia holes in the panel over the stud locations and then mount the rear pa...

Страница 73: ...slots and push the lower part of the grille back into position 2 Make sure that the grille and frame are firmly fitted together by engaging the tabs 3 Attach the thermistor on the grille Fig 17a 4 Close the cover and replace the screw Fig 17a 5 Affix the grille with the 2 previously removed screws Fig 16b 6 Install the air intake grille a Allow the edge of the air intake grille to slide into the t...

Страница 74: ...e frame Fig 18a 1 6 Pull the grill toward you to remove it How to replace the grille 1 When installing the grille place the bottom of the grille into the frame first Fig 18b 1 Then insert the tabs on the top of the grille and on the front face into the frame 2 Make sure that the grille and frame are firmly fitted together by engaging the tabs 3 Attach the thermistor on the grille Fig 17a 1 4 Close...

Страница 75: ...iagram 2 Provide a power outlet to be used exclusively for each unit with a power supply disconnect and cir cuit breaker for overcurrent protection provided in the exclusive line 3 To prevent possible hazard due to insulation failure the unit must be grounded 4 Each wiring connection must be done tightly and in accordance with the wiring system diagram Wrong wiring may cause the unit to misoperate...

Страница 76: ...iring from the back of the indoor unit and pull it toward the front for connec tion Figs 26a and 26b 5 Connect the inter unit wiring to the corresponding terminals on the terminal plate Figs 26a and 26b while referring to the wiring diagram 6 Be sure to secure the wiring with the provided clamp When closing the air intake grille press the bottom right and left corners and center Fig 27 Please refe...

Страница 77: ...the terminal screw 4 Shape the loop wire properly place it on the termi nal plate and fix it securely with the removed termi nal screw using a screwdriver I For stranded wiring 1 Cut the wire end with a cutting pliers then strip the insulation to expose the stranded wiring about 3 8 10 mm and tightly twist the wire ends Figs 30 and 31 2 Using a screwdriver remove the terminal screw s on the termin...

Страница 78: ...or unit so it is securely seated on the rear panel Fig 36 3 Carefully bend the tubing if necessary to run along the wall in the direction of the outdoor unit and then tape as far as the fittings See Caution on page 15 in the outdoor unit installation manual The drain hose should come straight down the wall to a point where water runoff won t stain the wall 4 Connect the refrigerant tubing to the o...

Страница 79: ...the drain hose fully onto the drain pan outlet until the drain hose edge is pushed into the insula tion Check that the screw holes in the drain bracket and the drain pan outlet are aligned and securely in contact then fasten them with the screw After attaching the drain hose check that it is attached securely Fig 40c Drain cap Use a Phillips screwdriver to push the drain cap in firmly If it is dif...

Страница 80: ...f the hose c If the drain hose will run in the room insulate the hose with insulation so that chilled condensation will not damage furniture or floors Fig 44 Foamed polyethylene or its equivalent is recom mended WARNING Risk of Electric Shock Do not supply power to the unit or operate it until all tubing and wiring to the out side unit are completed Condensation Insulation material Locally purchas...

Страница 81: ...ing uncooled forced air with the 4 indicator lamps OPERATION lamp TIMER lamp QUIET lamp and ION lamp on the main unit blinking Fig 59c After 3 minutes the system shifts into cooling opera tion and cool air will start to be felt Cool mode test run is unaffected by the room temperature 3 Press the ON OFF operation button of the remote con troller again to stop the test run Fig 59a 4 Finally press th...

Страница 82: ...there is an obstacle between the remote con trol unit and the air conditioner since a check signal is sent from the remote control unit every 5 minutes 5 1 Mounting on a Wall Before mounting the remote control unit press the ON OFF operation button at the mounting location to make sure that the air conditioner operates from that location The indoor unit should make a beeping sound to indicate that...

Страница 83: ...n object such as the tip of a pen to press the ACL button When this has been done oP 1 test run appears blinking in the remote controller clock display area 4 Each time the 1 HR TIMER button is pressed the display changes as shown below Press this button 2 times to change the display to oP 7 address setting Fig 64 5 oP 7 has now been selected for address setting 6 Press the ON OFF operation button...

Страница 84: ...ed level and vertically The power and voltage are as specified Inter unit cables are securely inserted into the terminal block Inter unit cables are securely fixed The power cord and inter unit cables are not connected anywhere along their paths The ground wire is securely connected Thermal insulation has been applied to the tubing connections Drain connections are secure and water drains properly...

Страница 85: ... Contact SANYO Fisher Service Company A Division of SANYO North America Corporation 1165 Allgood Road Suite 22 Marietta GA 30062 U S A Sanyo Canada Inc 1 300 Applewood Crescent Concord Ontario L4K 5C7 CANADA Sept 2006 T ...