background image

INSTRUCTION MANUAL

Split System Heat Pump

Wall-mounted type

Ceiling-mounted type

Recessed type

KHS2432

THS2432

XHS2432

KHS3632

THS3632

XHS3632

THS4232

XHS4232

Save This Instruction Manual

Pub. OI-85464189212002

©SANYO 2003

Содержание KHS2432

Страница 1: ...ON MANUAL Split System Heat Pump Wall mounted type Ceiling mounted type Recessed type KHS2432 THS2432 XHS2432 KHS3632 THS3632 XHS3632 THS4232 XHS4232 Save This Instruction Manual Pub OI 85464189212002 SANYO 2003 ...

Страница 2: ...ions include automatic on off with time settings same time on off every day on timer and off timer 1 Hour OFF Timer This timer turns off the unit one hour after the button is pressed Night Setback Pressing the Night Setback button changes the setting of the room temperature thermostat so that you do not experience excessive cooling or heating when sleeping Automatic and 3 step Fan Speed Auto High ...

Страница 3: ...leshooting 24 Tips for Energy Saving 24 Operating Range 24 Product Information The following information is useful when calling a service person Please fill in the blanks below The model and serial numbers are on the nameplate at the bottom of the cabinet Model No Serial No Date of purchase Dealer s address Phone number Warning Symbols The following symbols are used in this manual to alert to pote...

Страница 4: ...r units the flaps move for one minute when the power is supplied to the unit This is not a malfunction Safety Instructions Read this Instruction Manual carefully before using this air conditioner If you still have any difficulties or problems consult your dealer for help This air conditioner is designed to give you comfortable room conditions Use this only for its intended purpose as described in ...

Страница 5: ...irflow can be adjusted as desired using the remote control unit Remote control unit The wireless remote control unit controls power ON OFF operation mode selection temperature fan speed timer setting and air sweeping Refrigerant tubes The indoor and outdoor units are connected by copper tubes through which refrigerant gas flows Drain tube Moisture in the room is condensed and drains off by means o...

Страница 6: ...lter Recessed type Air intake grille Operation selector Ceiling mounted type Air intake grille Finger hold Operation selector 1 TEST RUN 2 PCB CHK ON 3 RCU MAIN OFF 4 OFF ADDRESS SERVICING switches ADDRERS switch NORM HOLD switch SWEEP button ON OFF operation button STANDBY lamp SERVICING switches ADDRESS switch NORM HOLD switch SWEEP button ON OFF operation button 6 OI 212 06EG ...

Страница 7: ...o turn off power completely TEST position This position is used only when servicing the air conditioner CAUTION Do not set at the TEST position for normal operation OPERATION lamp This lamp lights when the system is in the continuous AUTO HEAT COOL or FAN mode STANDBY lamp This lamp lights when the system is warming up for heating and when the system is defrosting To keep a constant room temperatu...

Страница 8: ... ON Timer 24 hour OFF Timer 1 hour OFF Timer 5 NIGHT SETBACK 6 Confirmation of transmission 7 Sweep indication 8 OI 212 08EG Displayed when main unit sensor is in use ROOMTEMP is displayed when the temperature setting has not been made Displayed when transmitting data TEMP is displayed when setting temperature Displayed when temperature is shown Displayed when the temperature setting is at the upp...

Страница 9: ...r inside the remote control unit senses the room temperature Display Information on the operating conditions is displayed while the remote control unit is switched on If the unit is turned off only the mode that was set previously is still displayed NIGHT SETBACK button For details see Night Setback Mode When you press this button in the COOL or HEAT mode the mark appears in the display and the re...

Страница 10: ...itch Change the address switch to prevent mixing of signals from remote control units when two Sanyo air conditioners are installed next to each other Normally the remote control address switch is set to A For the second indoor unit both addresses of the remote control unit and the indoor unit must be changed The second remote control unit address must be changed to B by breaking off the tab A And...

Страница 11: ...l unit more than 1 month take out the batteries How to Use the Remote Control Unit When using the remote control unit always point the unit s transmitter head directly at the air conditioner s receiver Transmitter head Remote Control Unit Installation Position The remote control unit may be operated either from a non fixed position or from a wall mounted position To ensure that the air conditioner...

Страница 12: ... Do not place objects which may block the transmitted signals between the receiver and the remote control unit Securing the remote 1 Attach the holder to the wall with one screw in the upper hole only control unit to prevent theft 2 Remove the cover from the remote control unit and then remove the batteries Next place the remote control unit in the holder 3 Secure both the remote control unit and ...

Страница 13: ...utton STEP 1 Press the MODE selector to STEP 2 Press the ON OFF operation button To stop the air conditioner press the ON OFF operation button again NOTE To change the temperature setting press the temperature setting buttons and change the setting to the desired temperature The indicates the upper limit for the temperature setting and the indicates the lower limit 13 OI 212 13EG STEP 2 STEP 1 The...

Страница 14: ...e air conditioner press the ON OFF operation button STEP 3 Press the TEMP setting buttons to change the temperature setting to the desired temperature Adjustable temperature range 86 F max 60 F min STEP 4 Set the FAN SPEED selector button to the setting you want NOTE If the fan speed is set to Automatic the fan speed switches automatically according to the difference between the actual room temper...

Страница 15: ...peed automatically when the mode is selected When the air conditioner starts operating the difference between the room temperature and the set temperature is detected by the microcomputer which then automatically switches the fan speed to a suitable level Cooling mode When difference between room temperature and set temperature is FAN SPEED 4 F and over High Between 4 F and 2 F Medium Below 2 F Lo...

Страница 16: ...N OFF button STEP 3 Press the FAN SPEED selector button to select the fan speed of your choice or 5 Night Setback Mode Night Setback Mode is used for saving energy Press the NIGHT SETBACK button during operation The mark appears in the display To release the night setback function press the NIGHT SETBACK button again NOTE The night setback mode cannot be used during automatic operation 16 OI 212 1...

Страница 17: ...is function is convenient when gentle cooling is needed Set temperature Pressing the NIGHT SETBACK button 2 F 2 F 30 min 30 min Time When the night setback mode is selected the air conditioner automatically lowers the temperature setting 4 F when 30 minutes have passed after the selection was made and then another 4 F after another 30 minutes have passed regardless of the indoor temperature when n...

Страница 18: ...e MM button until 10 is displayed The time indication alone blinks The display will automatically stop blinking except for the symbol after 10 sec The timer indication blinks and present OFF time is shown The display will change automatically back to show the present time after 10 sec The present time is displayed The present time and are displayed In case of power failure the unit will stop When ...

Страница 19: ...o start operation at 7 10 am and stop the air conditioner at 11 30 pm 1 Set the timer ON OFF times as shown in 2 and 3 2 Press the ON OFF button to start the air conditioner 3 Press theTIMER SELECT button to set the ON OFF combination timer NOTE When the Daily ON OFF program is set to start the air conditioner before the ON time setting the indications appear on the display On the other hand when ...

Страница 20: ...and then press the ON OFF operation button again The 1 HourTimer function is now cancelled and the unit operates normally NOTE If while the 1 HourTimer function is operating the 1 HR TIMER button is pressed once to cancel the function and then again the unit continues to operate for one hour from that point in time and then stops 2 OperationTogether with the ProgramTimer The 1 Hour OFFTimer settin...

Страница 21: ...ertical XHS Type are the recommended flap positions for cooling CAUTION Do not move the flap with your hands Operation without the Remote Control Unit If you have lost the remote control unit or it is not working follow the steps below 1 When the air conditioner is stopped If you want to turn on the air conditioner switch the operation selector to the OFF position and then to the ON position NOTE ...

Страница 22: ...e cleaned every year Consult your dealer or service center Air filter The air filter collects dust and other particles from the air and should be cleaned about once every six months Recessed type or two weeks ceiling mounted type and wall mounted type If the filter gets blocked the efficiency of the air conditioner drops greatly NOTE The frequency with which the filter should be cleaned depends on...

Страница 23: ...Outdoor Unit CAUTION 1 Certain metal edges and the condenser fins are sharp and may cause injury if handled improperly special care should be taken when you clean these parts 2 Periodically check the outdoor unit to see if the air outlet or air intake is clogged with dirt or soot 3 The internal coil and other components of the outdoor unit must also be cleaned periodically Consult your dealer or s...

Страница 24: ...to ensure good air flow 5 Thermostat is set too high 5 Set the temperature lower Tips for Energy Saving Do not Block the air intake and outlet of the unit If either is obstructed the unit will not work well and may be damaged Let direct sunlight into the room Use sunshades blinds or curtains If the walls and ceiling of the room are warmed by the sun it will take longer to cool the room Do Always t...

Страница 25: ...SANYO FISHER COMPANY A DIVISION OF SANYO NORTH AMERICA CORPORATION 21605 Plummer Street Chatsworth CA 91311 U S A In Canada SANYO Canada Inc 300 Applewood Crescent Concord Ontario L4K 5C7 Canada ...

Отзывы: