Страница 1: ...INSTRUCTION MANUAL Split System Air Conditioner COOL DRY HEAT Model KHS0951 KHS1251 KHS1852 Save These Instructions Pub OI 85264180351004 SANYO 2002 Printed on Recycled Paper ...

Страница 2: ... air in a sweeping motion around the room and providing comfort in every corner Automatic Switching between Cooling and Heating This unit automatically switches between cooling operation and heating operation according to the difference between the room temperature and the temperature setting Hot Start Heating System Right from the start the air is warm and comfortable This system prevents any col...

Страница 3: ...rgy Saving 26 Troubleshooting 27 Operating Range 27 Product Information If you have problems or questions concerning your Air Conditioner you will need the following information Model and serial numbers are on the nameplate on the bottom of the cabinet Model No Serial No Date of purchase Dealer s address Phone number Alert Symbols The following symbols used in this manual alert you to potentially ...

Страница 4: ...he supply wiring 3 Wiring must be done by a qualified electrician Safety Instructions Read this Instruction Manual carefully before using this air conditioner If you still have any difficulties or problems consult your dealer for help This air conditioner is designed to give you comfortable room conditions Use this only for its intended purpose as described in this Instruction Manual Never use or ...

Страница 5: ...f the air conditioner through the air outlet Remote Control Unit The wireless remote control unit controls power on off operation mode selection temperature fan speed timer setting night setback and air sweeping Refrigerant Tubes The indoor and outdoor units are connected by copper tubes through which refrigerant gas flows Drain Hose Moisture in the room condenses and drains off through this hose ...

Страница 6: ...e TEST position for normal OPERATION lamp This lamp lights when the system is in the continuous HEAT DRY and COOL mode TIMER lamp This lamp lights when the system is being controlled by the timer ON OFF TEST OPERATION lamp Operation selector Remote control receiver INDOOR UNIT KHS1852 TIMER STANDBY lamp lamp IMPORTANT Avoid using radio equipment such as mobile phones near within 4 ft of the indoor...

Страница 7: ...r lower allowable limit Displayed when temperature is shown Displayed when transmitting data Displayed when main unit sensor is in use 60 86 F When set to 82 F Current temperature indication 4 Timer 5 NIGHT SETBACK 6 Confirmation of transmission 7 Flap Angle indication Sweep indication ON OFF 1HR Symbols 7 OI 351 07EG oi202000 24 hour ON Timer program Timer ROOM TEMP is displayed when the temperat...

Страница 8: ...inside the remote control unit senses the room temperature Display Information on the operating conditions is displayed while the remote control unit is switched on If the unit is turned off only the mode that was set previously is still displayed NIGHT SETBACK button For details see Night Setback Mode When you press this button in the DRY COOL or HEAT mode the mark appears in the display and the ...

Страница 9: ...IMER operating or stopping the unit operates for one hour and then shuts down ACL button ALL CLEAR Puts the remote control unit into pre operation status Always press this button after replacing the batteries ADDRESS switch Change the address switch to prevent mixing of signals from remote control units when two Sanyo air conditioners are installed next to each other Normally the address switch is...

Страница 10: ...rated either from a non fixed position or from a wall mounted position To ensure that the air conditioner operates correctly DO NOT install the remote control unit in the following places DO NOT In direct sunlight Behind a curtain or other places where it is covered More than 26 feet 8 m away from the air conditioner In the path of the air conditioner s airstream Where it may become extremely hot ...

Страница 11: ... Do not place objects which may block the transmitted signals between the receiver and the remote control unit Securing the remote 1 Attach the holder to the wall with one screw in the upper hole only control unit to prevent theft 2 Remove the cover from the remote control unit and then remove the batteries Next place the remote control unit in the holder 3 Secure both the remote control unit and ...

Страница 12: ...er automatically bring the room to the desired temperature simply by pressing the ON OFF operation button STEP 1 Press the MODE selector to select STEP 2 Press the ON OFF operation button To stop the air conditioner press the ON OFF operation button again NOTE To change the temperature setting press the temperature setting buttons and change the setting to the desired temperature The temperature s...

Страница 13: ... speed is set automatically you can change the fan speed by pressing the FAN SPEED selector button To stop the air conditioner press the ON OFF operation button again Press the upper TEMP button to raise the temperature setting Press the lower TEMP button to lower the temperature setting 13 OI 351 13EG oi202000 ...

Страница 14: ...n For cooling operation STEP 2 To start the air conditioner press the ON OFF operation button STEP 3 Press the TEMP setting buttons to change the temperature setting to the desired temperature Adjustable temperature range 86 F max 60 F min STEP 4 Set the FAN SPEED selector button to the setting you want NOTE If the fan speed is set to Automatic the fan speed switches automatically according to the...

Страница 15: ...erature is detected by the microcomputer which then automatically switches the fan speed to the most suitable level Cooling and DRY mode When difference between room temperature and set temperature is FAN SPEED 4 F and over High Between 4 F and 2 F Medium Below 2 F Low Heating mode When difference between room temperature and set temperature is FAN SPEED 4 F and over High Below 4 F Medium or 15 OI...

Страница 16: ...etback Mode The Night Setback Mode is used for saving energy Press the NIGHT SETBACK button while the air conditioner is operating The mark appears in the display To cancel the night setback function press the NIGHT SETBACK button again 16 OI 351 16EG oi202000 ...

Страница 17: ...comfort This function is convenient when gentle cooling is needed Setting temperature Press the NIGHT SETBACK button 2 F 2 F 30 min 30 min Time B In Heating Mode When the night setback mode is selected the air conditioner automatically lowers the temperature setting 4 F when 30 minutes have passed after the selection was made and then another 4 F after another 30 minutes have passed regardless of ...

Страница 18: ...s This interval will vary slightly depending upon the outdoor temperature and the way in which frost forms STANDBY lamp For several minutes after the start of heating operation the indoor fan will not start running until the indoor heat exchanger coil has warmed up sufficiently This is because the COLD DRAFT PREVENTION SYSTEM is operating During this period the STANDBY lamp remains lit The STANDBY...

Страница 19: ... symbol after 10 sec 1 2 4 3 2 How to set the OFF time Example To stop the air conditioner at 11 30 pm 1 Press the Program button once 2 Press the HH button until PM 11 is displayed Press the MM button until 30 is displayed 3 Press the ON OFF button to start the air conditioner 4 Press theTIMER SELECT button to set OFF time The timer indication blinks and present OFF time is shown The display will...

Страница 20: ...art operation at 7 10 am and stop the air conditioner at 11 30 pm 1 Set the timer ON OFF times as shown in 2 1 2 and 3 1 2 2 Press the ON OFF button to start the air conditioner 3 Press theTIMER SELECT button to set the ON OFF combination timer NOTE When the Daily ON OFF program is set to start the air conditioner before the ON time setting the indications appear on the display On the other hand w...

Страница 21: ... and then press the ON OFF operation button again The 1 HourTimer function is now cancelled and the unit operates normally NOTE If while the 1 HourTimer function is operating the 1 HR TIMER button is pressed once to cancel the function and then again the unit continues to operate for one hour from that point in time and then stops 2 OperationTogether with the ProgramTimer The 1 Hour OFFTimer setti...

Страница 22: ... deliver air over the sweep range Referring to the above illustration use the FLAP button to set the airflow direction within the range used during the heating cooling or dehumidifying operation NOTE The flap automatically closes when the unit is off During the heating operation the fan speed will be very low and the flap will be in the horizontal position position 6 until the air being blown out ...

Страница 23: ...e indoor unit to clean it This will damage the internal components and cause an electric shock hazard Casing and Grille Indoor Unit Clean the casing and grille of the indoor unit with a vacuum cleaner brush or wipe them with a clean soft cloth If these parts are stained use a clean cloth moistened with a mild liquid detergent When cleaning the grille be careful not to force the vanes out of place ...

Страница 24: ...intake grille should be checked and cleaned at least once every two weeks How to remove the anti mold filter 1 Grasp both ends of the air intake grille and pull it out and up 2 Push the anti mold filter up slightly and then pull it down Cleaning Use a vacuum cleaner to remove light dust If there is sticky dust on the filter wash the filter in lukewarm soapy water rinse it in clean water and dry it...

Страница 25: ...l heating appliances Otherwise there is a risk of suffocation in extreme cases How to install the air cleaning filter The air cleaning filter needs to be installed behind the anti mold filter 1 Remove the anti mold filter 2 To mount the STK F4B set the air clean filter sold separately at the mounting position with the black side facing the rear To mount the STK ARF4B mount the air clean filter in ...

Страница 26: ...the like Then wipe away any remaining moisture Neutral detergent may be used to remove stubborn dirt Then rinse thoroughly with water and wipe away any remaining moisture Tips for Energy Saving Do not Block the air intake and outlet of the unit If they are obstructed the unit will not work well and may be damaged Let direct sunlight into the room Use sunshades blinds or curtains If the walls and c...

Страница 27: ... 5 Thermostat is set too high for cooling or too low for heating 6 Outdoor temperature is too low 1 Clean air filter to improve airflow 2 Eliminate heat source if possible 3 Shut them to keep the heat or cold out 4 Remove it to ensure good airflow 5 Set the temperature lower or higher 6 Consult your dealer or try to use a back up heater Clicking sound is heard from the air conditioner In heating o...

Страница 28: ...000 oi202000 SANYO FISHER COMPANY A DIVISION OF SANYO NORTH AMERICA CORPORATION 21605 Plummer Street Chatsworth CA 91311 U S A In Canada SANYO Canada Inc 300 Applewood Crescent Concord Ontario L4K 5C7 Canada ...