- 1 -
(3) (a) Set cooking time to two (2) minutes. (“2 00”
appears in display)
(b) Touch “START” key and operate oven for exactly
two (2) minutes.
(4) (a) Take out the two bowls at once.
(b) Stir both water with thermometer and measure the
water temperature rise respectively.
(5) (a) Get temperature rise by calculation the difference
(water temperature after cooking minus initial
temperature) in each bowl.
(b) Then calculate average value(t) of both temperature
rise in degrees centigrade.
(c) Then work out :
Power Output (watt) = 70 x
∆
t
Where
∆
t is an Average Temperature Rise in degrees
centigrade.
(6) Power Output shall be in the following range :
(7) Power Output will be influenced by line voltage of
power supply. Consequently, correct Power Output
must be measured within 240V AC ± 2 Volts while
unit is operating.
Test Procedures............................................ 3 ~ 4
Exploded View and Parts List ......................... 5 ~ 10
Overall Circuit Diagram .................................. 11
Specifications ....................................................... 1
Power Output Measurement .................................. 1
Circuit Diagram .................................................... 2
1. SPECIFICATIONS
Rated Power Consumption .. 1500W.
Microwave Output .............. 1000W.
Frequency .......................... 2,450MHz±50MHz.
Power Supply ..................... 230 ~ 240V, 50Hz.
Rated Current ..................... 6.6 Amp.
Safety Devices ................... Temp. Fuse open at
167
o
C for Cavity.
Thermal Protector open at
122
o
C for Magnetron,
Fuse (Cartridge Type 8A),
Primary Interlock Switch,
Door Sensing Switch and
Relay 2.
Interlock Monitor Switch.
Timer ................................ Electronic Digital, up to
99 min. 99 sec.
Overall Dimensions ............. 525(W) x 425(D) x 289(H)mm.
Oven Cavity Size ................ 351(W) x 371(D) x 208(H)mm.
Turn Table Diameter ............ 275mm
Effective Capacity of
Oven Cavity ....................... 28 litres.
Net Weight ........................ Approx. 17 Kg.
2. POWER OUTPUT MEASUREMENT
NOTE
The Power Output specification 1000W on this model
is measured with IEC measurement. The Power Output
is measured with two (2) litres water is equivalent to
1000W in measurement with IEC, when measured with
the following Power Output.
(1) (a) Fill two test bowls with each 1 litre water respectively.
(b) Use accurate thermometer and measure each
water temperature respectively.
(2) Place the two bowls on glass turntable.
- TABLE OF CONTENTS -
Average
Microwave
Temperature Rise
Power Output
Minimum
11.2
o
C
784W
Maximum
13.7
o
C
959W