Electric VRF

ISO 14001: 2001

Certificate Number: ECOOJ0303-33

Indicates conformation  

with EC Directives

ISO 9001: 2001

Certificate Number: JQ116B

SANYO reserves the right to make any variation in specification to the equipment described or to withdraw or replace products 

without prior notification or public announcement. All descriptions, illustrations, drawings and specifications in this publication 

are given in good faith, but are intended to present only general particulars and shall not form any part of the contract. For full 

installation details, please contact your SANYO distributor.

Rating Conditions

The cooling and heating capacities are based on the following conditions:  

Cooling: Indoor temperature 27˚C DB/19˚C WB, Outdoor temperature 35˚C DB/24˚ C WB.  

Heating: Indoor temperature 20˚C DB, Outdoor Temperature 7˚C DB 6˚C WB.

Printed using paper produced from 50% recycled material and 50% from sustainable forestry.

ELECTRIC VRF

GAS DRIVEN VRF

COMMERCIAL SPLIT SYSTEMS

ROOM AIR CONDITIONERS

HEATING SOLUTIONS

ECOi_VRF_V1_2009

GAS DRIVEN VRF

ELECTRIC VRF

ROOM AIR CONDITIONERS

CO

2

 ECO HEATING SYSTEM

Contact your local SANYO distributor 

for brochures on all other ranges of air 

conditioning and heating solutions

Содержание ECOi C0705DXHN8

Страница 1: ...ly general particulars and shall not form any part of the contract For full installation details please contact your SANYO distributor Rating Conditions The cooling and heating capacities are based on the following conditions Cooling Indoor temperature 27 C DB 19 C WB Outdoor temperature 35 C DB 24 C WB Heating Indoor temperature 20 C DB Outdoor Temperature 7 C DB 6 C WB Printed using paper produc...

Страница 2: ... maintenance calls and unit down time Lower running and life cycle costs SANYO ECOi VRF systems are amongst the most efficient VRF systems on the market offering COPs in excess of 4 0 at full load conditions The system is also designed to make sure that we reduce the running cost of each system by using our unique road map control routine to ensure that the most efficient combination of compressor...

Страница 3: ...d out with quotations through to installation guidance drawings The new PAC2 system software can be used for all SANYO ECOi GHP and PACi systems The new PAC2 system software can be used for all SANYO ECOi GHP and PACi systems Features include AC Calc Lite included in the package Easy to use system wizards Auto piping and wiring features Converted duties for conditions and pipework Auto CAD DXF exp...

Страница 4: ...s designed for creating a comfortable environment when either heating or cooling is required Heat pump systems offer heating or cooling Single footprint size for all unit capacities DC inverter technology combined with R410A for excellent efficiency System configuration from 8HP to 48HP Diversity ratio 50 130 Industry low outdoor unit sound levels from 54 5dB A Quiet mode offers a further 3dB A re...

Страница 5: ...HN8 10 C0905DXHN8 10 C0905DXHN8 10 C0905DXHN8 10 C0905DXHN8 12 C1155DXHN8 14 C1305DXHN8 16 C1405DXHN8 Power supply 380 400 415V 3 phase 50 60Hz Cooling capacity kW 22 40 28 00 33 50 40 00 45 00 50 40 56 00 61 50 68 00 73 00 78 50 85 00 90 00 96 00 101 00 107 00 113 00 118 00 124 00 130 00 135 00 Heating capacity kW 25 00 31 50 37 50 45 00 50 00 56 50 63 00 69 00 76 50 81 50 87 50 95 00 100 00 108 ...

Страница 6: ...mperature setting for heating operation has also been extended from 16 C to 30 C 8HP 48HP Cooling 10 C DB 43 C DB Heating 20 C WB 15 C WB Higher COPs lower running costs HP 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 EER Cooling 3 78 3 45 3 41 3 45 3 38 3 57 3 46 3 44 3 45 3 41 3 4 3 41 3 38 3 45 3 41 3 42 3 42 3 4 3 41 3 40 3 38 COP Heating 4 09 3 95 3 81 3 91 3 79 4 01 3 96 3 8...

Страница 7: ... 85 3 79 3 93 3 88 3 84 3 88 3 84 3 81 3 83 3 79 Electric ratings Cooling Running amperes A 10 0 9 5 9 2 13 7 13 0 12 6 16 6 15 7 15 2 20 0 19 0 18 3 23 0 21 8 21 0 23 8 22 6 21 8 27 3 26 0 25 0 30 2 28 7 27 7 33 6 31 9 30 8 36 5 34 7 33 5 39 4 37 5 36 1 43 0 40 8 39 4 45 9 43 6 42 1 47 5 45 1 43 5 50 5 48 0 46 3 53 0 51 0 49 0 57 0 54 0 52 0 60 0 57 0 55 0 63 0 60 0 58 0 66 0 63 0 60 0 69 0 65 0 ...

Страница 8: ...75XH SPW UR74GXH56B SPW U095XH SPW UR94GXH56B SPW U125XH SPW UR124GXH56B SPW U165XH SPW UR164GXH56B SPW U185XH SPW UR184GXH56B SPW U255XH SPW UR254GXH56B SPW U365XH SPW UR364GXH56B SPW U485XH SPW UR484GXH56B SPW U605XH SPW UR604GXH56B DR Type Concealed Duct SPW DR254GXH56B SPW DR364GX H56B SPW DR484GX H56B SPW DR764GXH56B SPW DR964GXH56B K Type Wall Mounted Unit SPW K075XH SPW K095XH SPW K125XH KR...

Страница 9: ...trol for setting Centralised control systems Operation with various function from central station Only ON OFF operation from central station Simplified charge ratio for each tenant Touch screen panel Personal computer field supply External appearance Type model name System controller SHA KC64AGB ON OFF controller SHA KC16KAGB Intelligent controller SHA KT256EG Communication adaptor SHA KA128AGB Nu...

Страница 10: ...a subject to change without notice Fresh air Exhaust air Return air Supply air Humidification optional DX coil Heat exchanger Installation example Timer remote controller RCS TM80BG Simplified remote controller RCS KR1EG Wireless remote controller Controller Options RCS BH80BG WL Rating Conditions Cooling Indoor 27 C DB 19 C WB Outdoor 35 C DB 24 C WB Heating Indoor 20 C DB Outdoor 7 C DB 6 C WB C...

Отзывы: