background image

SUBMITTAL SHEET

SYSTEM

INDOOR/OUTDOOR

36THS32

THS3632/CH3632

CEILING SUSPENDED HEAT PUMP

                 

                                                          

GENERAL DATA (AT 230V)

POWER   V/PH/HZ

230/208/1/60

Circuit Ampacity, Min. (A)

50

Fuse size, Max.

(A)

50

COMPRESSOR

Scroll

No. used

1

R.L. Amps - L.R. Amps (A)

15.2 -107.0

Crankcase Heater

30W

OUTDOOR FAN - TYPE

Propeller

Dia. (in.) - No. used

18-3/32 - 2

Type Drive - No. speeds

Direct ñ 2 (AUTO)

No. Poles - RPM (High)

6 - 879

No. Motors - WATTS   

2-110

CFM (High)

3,670

F.L. Amps. 

(A)

1.8

OUTDOOR COIL - TYPE

Aluminum Fin & Copper Pipe

Fin Type - Pipe Type

Slit Plate - Inner Riffled

Rows - F.P.I.

2 - 14.1

Face Area  (sq.ft.)

11.63

Tube Size  (in.)

3/8

INDOOR FAN - TYPE

Centrifugal

Dia. (in.) - No. used

5-29/32 - 4

No. speeds

3 & Auto

No. Poles -RPM  (High)

4 - 1,200

No. Motors - HP

1 - 3/25

CFM (HI/MED/LOW)

950/830/715

F.L. Amps (A)

0.9

INDOOR COIL - TYPE

Aluminum Fin & Copper Pipe

Fin Type - Pipe type

Slit Plate - Inner Riffled

Rows - F.P.I.

3 - 12.7

Face Area  (sq. ft.)

3.66

Tube Size  (in.)

3/8

Drain Connection Size (in.)

1-1/4

REFRIGERANT

R22

Lbs. - R22  (O.D. Unit)

8.82

Control

Electronic Expansion Valve

Connection

Flare

Line Length,  Max   (ft.)

165

Lift difference, Max   (ft.)

100

Line Size - in. O.D. Discharge

3/8

Line Size - in. O.D. Suction

3/4

DIMENSIONS  (in.)

H

x

W

x

D

Indoor Unit

-Uncrated 9-27/32x 61-13/16 x 26-3/8

-Crated

13-7/32 x 65- 3/4 x 30-25/32

Outdoor Unit -Uncrated 48-5/8 x 37

x 13-3/8

-Crated

52 -7/32 x 40

x 16-12/32

WEIGHT              

INDOOR 

OUTDOOR

Net (lbs.)    

98.0    

 198.0

Shipping (lbs.)  

123.0     

223.0

Shipping Volume      (cu.ft.)    15.5      

19.8

  

                                                                                                                                   

                            

   

                                                               SS36THS32-1

PERFORMANCE DATA @ ARI STANDARD CONDITIONS 

(230/208V)

COOLING
Total Capacity

(BTU/H)

36,000/35,000

Sensible Capacity

(BTU/H)

23,530/22,630

Latent Capacity

(BTU/H)

12,470/12,370

SEER

10.0/10.2

Dehumidification

(Pints/H)

10.4/10.2

Amps

(A)

17.5/18.3

Power Inputs

(W)

3,650/3,550

HEATING
Total Capacity

(BTU/H)

37,000/36,000

HSPF

7.2/7.2

Amps

(A)

16.7/16.6

Power Inputs

(W)

3,450/3,300

Back-up Strip Heater (KW)

3.00/2.45

Outdoor Sound Rating (bels)

8.0

FEATURE

Controls

Microprocessor

Remote Controller

LCD Wireless type

Temperature Control

IC Thermostat

Timer

ON/OFF, 24 hours

Night Setback

Built-IN

Air Louver (Horizontal)

Manual

(Vertical)

Automatic

Power Failure Automatic Restart

Built-In

Self Diagnosis

Built-In

Heating/Cooling Automatic Changeover

Built-In

OPTION

Refrigerant Line Set

AP3210BH  (30 ft)
AP3215BH  (50 ft)

Low Ambient Control

N/A

Fresh Air Intake

Available

Central Remote ON-OFF Control

Available

Airduct Extension

N/A

Indoor Frame Extension

N/A

Condensate Drain Pump

Available

Non-Removable Remo-con Bracket

Available

OPERATING RANGE

Cooling

Indoor Air

Outdoor Air

Intake Temp.

Intake Temp.

Maximum

95 F DB/71 F WB 115 F DB

Minimum

67 F DB/57 F WB   67 F DB

Heating

Maximum

80 F DB/67 F WB   75 F DB / 65 F WB

Minimum

- F DB/   - F WB   17 F DB/  15 F WB

 

CERTIFICATION

36THS32

AIRCONDITIONING PRODUCTS