background image

1

2

3

Save These  Instructions!

1. RCS-SH80UG

(Wired type: for all indoor units)

2. RCS-SH80UA.WL

(Wireless type: for X and T type indoor units)

RCS-BH80UA.WL

(Wireless type: for U type indoor unit)

RCS-SH1UA

(Wireless type: for K type indoor unit)

3. SHA-KC64UG

(System Remote Controller)

85464189788001

©SANYO 2006

SANYO Electric Co., Ltd.

Gunma, Japan

Split System Air Conditioner

INSTRUCTION MANUAL

Indoor Units

Wall-Mounted type

KH2672R

XH2672R

TH2672R

UH2672R

KH3072R

KH3672R

XH3672R

TH3672R

UH3672R

XH4272R

TH4272R

KHH2672R

THH2672R

THH3672R

Ceiling-Mounted type

Concealed-Duct type

4-Way Air Discharge

Semi-Concealed type

06-212 PAC-i_IM_Cover  4/12/06  7:14 PM  Page 1

Содержание 26KHS72R

Страница 1: ...ss type for K type indoor unit 3 SHA KC64UG System Remote Controller 85464189788001 SANYO 2006 SANYO Electric Co Ltd Gunma Japan Split System Air Conditioner INSTRUCTION MANUAL Indoor Units Wall Mounted type KH2672R XH2672R TH2672R UH2672R KH3072R KH3672R XH3672R TH3672R UH3672R XH4272R TH4272R KHH2672R THH2672R THH3672R Ceiling Mounted type Concealed Duct type 4 Way Air Discharge Semi Concealed t...

Страница 2: ...m Air Conditioner INSTRUCTION MANUAL Wall Mounted type KH2672R XH2672R TH2672R UH2672R KH3072R KH3672R XH3672R TH3672R UH3672R XH4272R TH4272R KHH2672R THH2672R THH3672R Ceiling Mounted type Concealed Duct type 4 Way Air Discharge Semi Concealed type ...

Страница 3: ... concerning your Air Conditioner you will need the following information Model and serial numbers are on the nameplate on the bottom of the cabinet Model No Serial No Date of purchase Dealer s address Phone number Alert Symbols The following symbols used in this manual alert you to potentially dangerous conditions to users service personnel or the appliance This symbol refers to a hazard or unsafe...

Страница 4: ...must be turned on at least five 5 hours before operation Leave the power mains ON unless you will not be using this appliance for an extended period Safety Instructions Read this Instruction Manual carefully before using this air conditioner If you still have any difficulties or problems consult your dealer for help The air conditioner is designed to give you comfortable room conditions Use this o...

Страница 5: ...CEALED DUCT U type Air outlet optional Ceiling Air intake optional REMOTE CONTROL UNITS optional Wired type Wireless type available for all available for indoor units X and T This illustration is based on the external appearance of a standard model Consequently the appearance may differ from that of the air conditioner you have selected System Remote Controller Wireless type available for U NOTE ...

Страница 6: ...Y Used for dehumidifying without changing the room temperature temperature range 64 86 F COOL Used for normal cooling operation temperature range 64 86 F FAN Used to run the fan only without heating or cooling operation D Temperature Press this button to increase the temperature setting setting buttons Press this button to decrease the temperature setting E FAN SPEED selector button AUTO The air c...

Страница 7: ... SET button Use this button while the unit is operating to switch between timer settings OFF Timer The air conditioner stops after the length of time set OFF Cycle Timer The air conditioner after the same set time every time ON Timer The air conditioner starts after the length of time set K Time setting buttons Press this button to increase the time Press this button to decrease the time L SET but...

Страница 8: ...e control unit or a sub remote control can set the timer Group control means that maximum up to 8 indoor units can be concurrently controlled with a remote control unit 2 If a power failure occurs in timer mode the time counted up to that point will be stored in memory After power is restored the timer starts again counting up to the set time NOTE Remote Control Unit continued NOTE ...

Страница 9: ...ng used for control When is flashing on the display the operation is not accepted by the system controller J This indicates the indoor unit address in case of group control Unit No 1 2 Indoor unit No Refrigerant circuit No K This is displayed when it is time to clean the filter L When setting the timer the selected timer mode is displayed M This indication appears when the temperature is set N Thi...

Страница 10: ...d switches automatically STEP 4 Setting the temperature Use the or button as appropriate to change the temperature setting as desired reduces the temperature and increases the temperature STEP 5 Setting the airflow direction When more than one indoor unit is connected the UNIT button is used first to select a unit Then use the FLAP button to set the airflow direction to a specific angle or to swee...

Страница 11: ...e the flap with your hands I Ceiling mounted type T A Vertical directions automatic This air conditioner is equipped with an auto flap You can set the airflow direction to a specific angle or to the sweep mode using the remote control unit Refer to the description of the remote control unit Do not move the flap with your hands B Horizontal directions manual The horizontal airflow direction can be ...

Страница 12: ...n more than 30 otherwise condensation may drip on to the floor Zone A is the recommended flap position for cooling Do not move the flap with your hands B Horizontal directions manual The horizontal airflow can be adjusted manually by moving the vertical vanes to the left or right I Concealed duct type U This air conditioner is not equipped with air outlet parts These must be obtained locally Pleas...

Страница 13: ... display until defrosting is completed Heating operation then restarts after several minutes This interval will vary slightly depending upon the outdoor temperature and the way in which frost forms For several minutes after the start of heating operation the indoor fan will not start running or it will run at very low speed in some cases until the indoor heat exchanger coil has warmed up sufficien...

Страница 14: ...ery time Use this mode to start the appliance automatically after the length of time set When two remote control units are being used either a main remote control unit or a sub remote control unit can be used for timer operations Refer to the description of the remote control unit OFF ON Set time OFF ON Set time OFF ON Set time OFF ON Set time OFF timer OFF cycle timer ON timer NOTE NOTE ...

Страница 15: ...5 hours Operation Indication 1 Press the ON OFF button to start the air conditioner 2 Press the TIMER SET button three times to select the mode 3 Press the button until 10 5 is displayed Press the button if the set time is exceeded 4 Press the SET button to set the ON timer When the ON timer is set the unit enters the paused state How to stop the timer operation Operation Indication Push the CL bu...

Страница 16: ... gets blocked the efficiency of the air conditioner drops greatly Concealed duct type U An air filter is not provided with this air conditioner at the time of shipment To get clean air and to extend the service life of the air conditioner an air filter must be installed in the air intake For installation and cleaning the air filter consult your dealer or service center The frequency with which the...

Страница 17: ...he bottom and pull downward When replacing the filter make sure that the FRONT mark is facing you Push it up until you hear it click back into position 1 Push up then Pull down Wall mounted type K Latch Bolt screw Air intake grille Safety chain Air filter Finger hold Air filter Air filter finger hold Catch Air intake grille Air filter How to remove the filter continued How to remove the filter con...

Страница 18: ... unit or heat 5 Consult your dealer pump is malfunctioning ERROR and characters such as E F H L P etc appear on the display Compressor runs but 1 Obstruction in front of condenser coil 1 Remove obstruction soon stops Poor cooling or heating 1 Dirty or clogged air filter 1 Clean the air filter to improve the performance airflow 2 Heat source or many people in room 2 Eliminate heat source if possibl...

Страница 19: ...CS SH80UA WL RCS BH80UA WL RCS SH1UA INSTRUCTION MANUAL Wireless Remote Controller for Split System For information on installing the wireless remote controller refer to the INSTALLATION INSTRUCTIONS accompanying the outdoor unit ...

Страница 20: ...ct Information If you have problems or questions concerning your Air Conditioner you will need the following information Model and serial numbers are on the nameplate on the bottom of the cabinet Model No Serial No Date of purchase Dealer s address Phone number Alert Symbols The following symbols used in this manual alert you to potentially dangerous conditions to users service personnel or the ap...

Страница 21: ...must be turned on at least five 5 hours before operation Leave the power mains ON unless you will not be using this appliance for an extended period Safety Instructions Read this Instruction Manual carefully before using this air conditioner If you still have any difficulties or problems consult your dealer for help The air conditioner is designed to give you comfortable room conditions Use this o...

Страница 22: ...d for cooling only the STANDBY lamp will not illuminate This lamp operates only when an alarm occurs Remote control receiver This section picks up infrared signals from the wireless remote controller transmitter Operation controller You can operate this air conditioner using the operation controller without the wireless remote controller OPERATION lamp TIMER lamp STANDBY lamp Remote control receiv...

Страница 23: ...used only when servicing the air conditioner Do not use these SERVICING switches for normal operation Turning off the ON OFF operation button does not disconnect the power Use the main power switch to turn off the power completely ADDRESS switch Switch SWEEP button ON OFF operation button To access the operation controller Press on the two latches of the air intake grille with your thumb in the di...

Страница 24: ...ion G ADDRESS switch When operating the air conditioner by using the wireless remote controller be sure to match the number on this switch with the number set on the wireless remote controller Otherwise the remote control will not work H OPERATION lamp This lamp lights when the appliance is turned on I TIMER lamp This lamp lights when the system is being controlled by the timer J STANDBY lamp When...

Страница 25: ... 00 The batteries last about six months depending on how much you use the wireless remote controller Replace the batteries when the wireless remote controllerʼs lamp fails to light or when the wireless remote controller cannot be used to change the air conditionerʼs setting Use two fresh leak proof type AAA alkaline batteries LR03 In replacing batteries follow the instructions as mentioned in the ...

Страница 26: ... the wireless remote controller mounting cradle and insert the wireless remote controller The unit can be used either in that position placed on a table for instance or held in the hand 2 If Wall mounted Fixed Position Install the wireless remote controller at a convenient location on a nearby wall However before attaching the wireless remote controller mounting cradle check that the wireless remo...

Страница 27: ...g setting buttons Press this button to decrease the temperature setting D FAN SPEED selector button AUTO The air conditioner automatically decides the fan speed HI High fan speed MED Medium fan speed LO Low fan speed E FILTER reset button Use this button to reset the filter sign The air conditioner has a timer for the filter and informs you when the filter needs cleaning When low fan speed is sele...

Страница 28: ...the wireless remote controller senses the room temperature when switched from a temperature sensor inside the indoor unit L VENTILATION button Use this button when you installed a ventilation fan available in the market Pressing this button turns on and off the fan When turning off the air conditioner the fan will be also turned off While the fan is operating will appear in the display M TRANSMITT...

Страница 29: ...oner regularly at three minute intervals If the signal from the wireless remote controller stops for more than ten minutes due to the loss of the wireless remote controller or other trouble the air conditioner will switch to the temperature sensor which is built into the indoor unit and control the room temperature In these cases the temperature around the wireless remote controller may differ fro...

Страница 30: ...or unit you want to operate to match its address with the address indicated on the remote controller 3 Press the SET button If the set address on the remote controller matches with the controller address in an indoor unit the buzzer will beep To set the address to 1 2 or 3 switch this SWITCH knob to the left to set the address to 4 5 or 6 switch this SWITCH knob to the right You can set any addres...

Страница 31: ...he fan speed switches automatically STEP 4 Setting the temperature Use the or button as appropriate to change the temperature setting as desired reduces the temperature and increases the temperature STEP 5 Setting the airflow direction When more than one indoor unit is connected the UNIT button is used first to select a unit Then use the FLAP button to set the airflow direction to a specific angle...

Страница 32: ...rflow direction STEP 1 To start the air conditioner Operate the receiver switch in the following sequence NORMAL OFF NORMAL automatically setting auto operation Then turn the switch to OFF STEP 2 To stop the air conditioner To adjust the airflow direction press the SWEEP button as appropriate You can only set the airflow for all four sides in the same direction or have each sweep STEP 3 To stop th...

Страница 33: ... operating During this period the STANDBY lamp remains lit STANDBY lamp remains lit during defrosting or when the compressor has been turned off or when the unit is running at very low speed by the thermostat when the system is in the heating mode Upon completion of defrosting and when the compressor is turned on again STANDBY lamp will light off automatically as the heating operation resumes When...

Страница 34: ...me every time Use this mode to start the appliance automatically after the length of time set When two remote control units are being used either a main remote control unit or a sub remote control unit can be used for timer operations Refer to the description of the remote control unit OFF Set time ON OFF Set time Set time ON OFF ON OFF Set time ON OFF timer OFF cycle timer ON timer ...

Страница 35: ...5 hours Operation Indication 1 Press the ON OFF button to start the air conditioner 2 Press the TIMER SET button three times to select the mode 3 Press the button until 10 5 is displayed Press the button if the set time is exceeded 4 Press the SET button to set the ON timer When the ON timer is set the unit enters the paused state How to stop the timer operation Operation Indication Push the CL bu...

Страница 36: ...upted Trouble Possible Cause Remedy Air conditioner does not 1 Power failure 1 Restore power run at all 2 Leakage circuit breaker has tripped 2 Contact service center 3 Line voltage is too low 3 Consult your electrician or dealer 4 Operation button is turned off 4 Press the button again 5 The wireless remote controller or 5 Consult your dealer heat pump is malfunctioning 6 Batteries in wireless re...

Страница 37: ...3 Save These Instructions SHA KC64UG System Controller for Split System Air Conditioner INSTRUCTION MANUAL ...

Страница 38: ...itioner you will need the following information Model and serial numbers are on the nameplate on the bottom of the cabinet Model No Serial No Date of purchase Dealer s address Phone number Alert Symbols The following symbols used in this manual alert you to potentially dangerous conditions to users service personnel or the appliance This symbol refers to a hazard or unsafe practice which can resul...

Страница 39: ...refully before using this system controller If you still have any difficulties or problems consult your dealer for help The air conditioner is designed to give you comfortable room conditions Use this only for its intended purpose as described in the Instruction Manual Never touch the unit with wet hands Never use or store gasoline or other flammable vapor or liquid near the air conditioner it is ...

Страница 40: ...s units in a zone can be set B ZONE select button Use this button to select a zone 1 to 4 to operate individually C GROUP select buttons Use these buttons to select a group 1 to 16 to operate individually A ALL ZONE GR SELECT button B ZONE select button C GROUP select buttons F Operation lamp D ON button E OFF button G MODE button H Temperature setting buttons O VENTILATION button K CHECK button L...

Страница 41: ... Press this button to decrease the temperature setting I FAN SPEED button AUTO The air conditioner automatically decides the fan speed HI High fan speed MED Medium fan speed LO Low fan speed J FLAP button 1 Use this button to set the airflow direction to a specific angle The airflow direction is displayed on the remote control unit In the cool mode and dry mode when the flaps are set in a downward...

Страница 42: ...ed Individual operation M SET button This button is used for setting indoor unit s address when installing the air conditioner Do not use the SET button for normal operation N CL button Use this button to reset the filter sign The air conditioner has the timer for the filter and informs you when the filter needs cleaning O VENTILATION button Use this button when you installed a fan available in th...

Страница 43: ... on no sign off alarm G The currently selected central control mode 1 2 3 or 4 is displayed H Lights when any of the air conditioners under the system control is operating turns off when none of the air conditioners under the system control is operating Blinks when any conditioner is operating under abnormal conditions and its protection functionality is working I When the button is pressed for mo...

Страница 44: ...rection to a specific angle or sweep mode 9 By pressing select your desired setting Individual Controls with the remote controller are possible Central 1 Individual ON OFF operation with the remote controller is inhibited Central 2 Individual ON OFF MODE and Temp setting operations with the remote controller are inhibited Central 3 Individual MODE and Temp setting operations with the remote contro...

Страница 45: ...1 Press the SELECT button and select ALL or ZONE In case of ZONE collective operation 2 Select the ZONE No to be operated by pressing ZONE button 3 Press the ON button 4 Set the operation mode by pressing the MODE button 5 Set the desired temperature by pressing one of the temperature setting buttons 6 Set the desired fan speed by pressing the FAN SPEED button 7 Select the control mode Stop Confir...

Страница 46: ...3 ...

Страница 47: ...3 ...

Страница 48: ...SANYO FISHER COMPANY A DIVISION OF SANYO NORTH AMERICA CORPORATION 21605 Plummer Street Chatsworth CA 91311 U S A In Canada SANYO Canada Inc 300 Applewood Crescent Concord Ontario L4K 5C7 Canada ...

Отзывы: