5-6
MAINTENANCE
SY95C Excavator OMM
Cold Environments
In extremely cold environments, 32°F (0°C) or below,
lubricate only with the oils as shown in “Recommended
Lubricants, Fuel, and Engine Coolant” on page 5-7.
SANY recommends the use of fuels identified in
“Recommended Lubricants, Fuel, and Engine Coolant”
on page 5-7 for extremely cold environments.
Prior to starting the engine, make sure the battery is fully
charged and the battery case and the cables have not
cracked.
Other Weather Environments
NOTE:
If there is evidence of overheating of bearings or
bushings, loose parts, or rust during regular
inspection, increase the frequency of lubrication.
Based on experience and suggestions by lubricating oil
suppliers, the lubricating intervals listed in the
“Maintenance Schedule” on page 5-9 apply only to
normal operating conditions. In harsh environments,
including those with dusty and corrosive air, abnormal
external temperature, extremely heavy loads, frequent
operating times, longtime duty cycle, etc., lubricating
intervals should be shortened.
Maintenance Log
Check the maintenance log if all tasks have been
completed before and after servicing or operating the
machine. The maintenance log lists regularly scheduled
maintenance that should be performed by the operator or
service personnel. All maintenance performed on the
machine must be recorded in the maintenance log.
Daily Inspection and Maintenance
Do the following before operation with the engine off:
• Perform daily service as necessary.
• Inspect the machine for loose or missing
components.
• Clean the operator station.
• Check all controls for smooth operation and make
sure they return to the neutral position.
• Make sure all safety decals are in place and are
legible.
• Make sure safety equipment is in place and in
operating condition.
• Check for fluid leaks.
Check the following during operation with the engine
running:
• Monitor the control panel for normal machine
operating parameters.
• Make sure that the machine operates normally.
• Check for fluid leaks.
Check the following after operation with the engine off
and cool:
• Check service points for wear or damage.
• Clean the operator station.
• Check for fluid leaks.
• Check for loose or missing fasteners and
components.
Содержание SY95C
Страница 2: ...Page Intentionally Blank ...
Страница 146: ...5 48 MAINTENANCE SY95C Excavator OMM Page Intentionally Blank ...
Страница 151: ...SPECIFICATIONS 6 5 SY95C Excavator OMM Load Point Radius and Height 0003873 Figure 6 3 ...
Страница 154: ...6 8 SPECIFICATIONS SY95C Excavator OMM Page Intentionally Blank ...
Страница 164: ...I 6 SY95C Excavator OMM ...
Страница 165: ...Page Intentionally Blank ...