3-16
MACHINE CONTROLS
SY60C Excavator OMM
• The DPF Regen Req lamp message will go out.
Simultaneously, the DPF Regen Ack lamp message
and exhaust gas temperature (EGT) lamp message
(5) will illuminate steadily.
NOTICE!
If the red engine stop lamp (8) illuminates, shut
down the engine immediately. Contact a SANY
dealer for further information.
Failure to follow this notice could damage the
machine or cause it to operate improperly.
NOTE:
A DPF regeneration in-progress message will
display on the DPF Regeneration screen with a
caution message of high exhaust temperatures.
6.
When the regeneration cycle is complete, the engine
returns to low idle and a manual DPF regeneration
completed message is displayed. The DPF Regen
Ack icon extinguishes automatically.
7.
If it is necessary to abort the stationary regeneration,
press the button below the DPF regeneration inhibit
icon (11). The DPF Regen Inhibit lamp (9) will
illuminate and the regeneration cycle will be stopped.
Shut down the engine. See “Engine Shutdown” on
page 4-14.
NOTE:
Press the button below the return icon (12) to
return to the previous screen.