5-24
MAINTENANCE
SY500H Excavator OMM
0004753
Figure 5-19
2. Check the clamps (1) on the exhaust system and
make sure they are tight.
NOTE:
Tighten as required. Replace damaged, worn, or
missing clamps. Not all clamps are shown in this
illustration.
Replace the Diesel Exhaust Fluid (DEF)
Pump Filter
Perform this procedure every 4500 hours of operation or
3 years, whichever comes first.
1. Open the right front access door. See “Right Front
0004754
Figure 5-20
2. Locate the DEF pump (1).
3. Remove the DEF pump filter housing (2) from the
bottom of the pump.
0000757
Figure 5-21
4. Remove the old filter element (3) and replace it with a
new one.
5. Install a new DEF pump filter housing O-ring (4).
6. Install the DEF pump filter housing.
1
1
2
3
4
Содержание SY500H
Страница 2: ...Page Intentionally Blank ...
Страница 14: ...5 10 SY500H Excavator OMM Page Intentionally Blank ...
Страница 30: ...2 8 SAFETY SY500H Excavator OMM Page Intentionally Blank ...
Страница 70: ...3 40 MACHINE CONTROLS SY500H Excavator OMM Page Intentionally Blank ...
Страница 172: ...5 64 MAINTENANCE SY500H Excavator OMM Page Intentionally Blank ...
Страница 174: ...6 2 SPECIFICATIONS SY500H Excavator OMM Machine Dimensions 0000837 Figure 6 1 1 2 3 4 5 6 7 8 9 10 11 ...
Страница 180: ...6 8 SPECIFICATIONS SY500H Excavator OMM Page Intentionally Blank ...
Страница 194: ...I 8 SY500H Excavator OMM Page Intentionally Blank ...
Страница 195: ...Page Intentionally Blank ...