SY265C LC/SY265C LR Excavator OMM
SANY
Operation and Maintenance Manual — 0420
5-101
TABL
E OF
CONT
E
N
TS
INTRODUCTION
SAFE
T
Y
MACHIN
E
CONTROLS
MACHINE
OP
ERA
T
IO
N
MA
INTENANCE
SPEC
IFI
CA
TIO
N
S
OP
T
IO
N
A
L
EQUI
PMENT
10. Install the oil level check plug.
NOTE:
Repeat preceding steps for the other final drive as needed.
11. Follow the instructions included with the sample kit to send the sample for testing.
Collect a Swing Drive Oil Sample
1. Prepare the machine for service. See “Maintenance
2. Start the engine and operate the machine until all
systems reach normal operating temperatures.
3. Shut down the engine.
4. Remove the dipstick (1) from the swing drive.
5. Insert the sample tube into the swing drive dipstick
tube.
6. Collect a sample of swing drive oil.
7. Remove the sample tube.
8. Install the dipstick.
9. Follow the instructions included with the sample kit to send the sample for testing.
Fig. 5-137
00005215
1