SY265C LC/SY265C LR Excavator OMM
SANY
Operation and Maintenance Manual — 0420
5-69
TABL
E OF
CONT
E
N
TS
INTRODUCTION
SAFE
T
Y
MACHIN
E
CONTROLS
MACHINE
OP
ERA
T
IO
N
MA
INTENANCE
SPEC
IFI
CA
TIO
N
S
OP
T
IO
N
A
L
EQUI
PMENT
7. Check the hydraulic oil level using the sight glass (3)
on the side of the hydraulic tank. See “Check the
Hydraulic Oil Level” on page 5-29.
8. Install the suction strainer cover and secure using the
fasteners.
9. Start the engine.
10. Run the engine for 10 minutes to circulate hydraulic oil
through the hydraulic system.
11. Recheck the hydraulic oil level.
12. Check for leaks.
Replace the Hydraulic System Breather Filter
1. Prepare the machine for service. See “Maintenance
2. Clean the top of the hydraulic tank around the breather
housing (2).
3. Remove the wing nut (1) from the breather valve.
NOTICE!
Do not overfill the hydraulic tank. This could
result in machine damage and improper
machine operation.
Fig. 5-85
3
0000257
Fig. 5-86
2
00004158
1