Maintenance
SY215C LC/SY225C LC Excavator OMM
5-86
Operation and Maintenance Manual — 1219
SANY
5. With the engine running at low idle, press the
regeneration switch (5) on the right control console.
NOTE:
Do not move the hydraulic lockout control
lever or throttle control dial during cleaning.
Regeneration will stop if either the throttle
dial or hydraulic lockout lever is moved,
resulting in the process having to be started
again.
During the regeneration process:
•
The High Exhaust System Temperature (HEST)
icon (6) will appear on the monitor home screen.
•
The Diesel Particulate Filter icon will be on and the
yellow Check Engine icon may be on.
•
The engine speed may increase.
•
The turbocharger sound may change.
When the regeneration process is complete:
•
The HEST icon, Diesel Particulate Filter icon, and the yellow Check Engine icon will turn off.
•
The engine returns to low idle speed.
•
The turbocharger sound returns to normal.
6. Allow the engine to idle for 10 to 15 minutes to cool to normal operating temperatures before resuming work.
Perform a Structural Inspection
1. Prepare the machine for service. See “Maintenance Safety” on page 2-8.
2. Thoroughly wash the machine.
3. Inspect the machine structure for signs of damage or excessive wear.
Fig. 5-130