Maintenance
SY215C LC/SY225C LC Excavator OMM
5-22
Operation and Maintenance Manual — 1219
SANY
Check Accumulator Function
NOTE:
Perform this procedure every 6 months (1000 hours) of service on machines with optional equipment
attached. Perform this procedure annually (or every 2000 hours) on machines with a bucket attached.
1. Position the work equipment (1) 18 in.–24 in.
(457 mm–610 mm) from the ground.
2. Prepare the machine for service. See “Maintenance
3. Shut down the engine.
4. Turn the key switch to the ON position.
5. Place the hydraulic lockout control lever (2) in the open
(unlocked) position.
6. Move the right joystick down.
7. If the boom goes down, to the ground no action is
needed.
8. If the boom does not go down to the ground, contact a
SANY dealer.
9. Start the engine and run it at idle speed for about 1
minute to repressurize the accumulator.
Fig. 5-4
SANY
1
UNLOCKED
LOCKED
Fig. 5-5
2