Sanwa mobiken Series Скачать руководство пользователя страница 1

-7-

-8-

Light sensor element

Measurable wavelength
range

Directly-readable 
wavelength

Display

“Over” display

Low battery indication

Sampling rate

Measuring ranges

Measuring accuracy

Functions

Power supply

Power consumption 
Operating temperature
/humidity range

Storage temperature
/humidity range

Main body dimensions
& weight

Light sensor probe

Sensor cord length

Provided accessories

Si photodiode (Light sensor surface diameter Ø 9 mm)

400 nm to 1100 nm

633 nm (He-Ne laser)

Other wavelengths should be converted using typical 
correction coefficient

Digital display: 3999 full scale

Bar graph display: 42-segment display

“4000” with “4” in the highest digit blinking

Blinking “BT” appears in the display when the built-in batteries 
are nearly exhausted and battery supply voltage drops

Digital display: Approx. 2 times/sec.

Bar graph display: Approx. 20 times/sec.

40 

µ

W range: 0.01 

µ

W to 39.99 

µ

W

400 

µ

W range: 0.1 

µ

W to 399.9 

µ

W

4 mW range: 0.001 mW to 3.999 mW

40 mW range: 0.01 mW to 39.99 mW

±

5% (in the 4 mW range, at the reference wavelength of 

633 nm and 1 mW)

Temperature: 23

°

±

2

°

C

MIN Hold function, MAX Hold function

Auto power save function (30 min. after operation)

SR-44 or LR-44, x 2

Approx. 6 mW

Temperature 0 to 40

°

C, humidity 80%RH or less (without 

condensation) 

Temperature -10 to +50

°

C, humidity 80%RH or less 

(without condensation)

117(H) x 76(W) x 18(D) mm, approx. 120 grams

84(H) x 16(W) x 10(D) mm

Approx. 0.5 m when extended

Instruction manual x 1

To maintain accuracy, perform calibration and inspection at least once an year.

[7] Maintenance and Administration

[9] Specifications

[8] After-Sale Servicing

The panel and case are little resistant to volatile solutions and heat. Do 
not wipe the thermometer using lacquer thinner or alcohol and do not 
place it heat a source of high temperatures (soldering iron, for example).
Do not store the instrument in a place subject to vibrations 
or in a place which it may drop.
Do not store the instrument under direct sunlight or in a 
place with low temperatures, high humidity or condensation.
Be sure to remove the batteries when the instrument is not 
to be used for an extended period.

For information of  repair, please contact the dealer, selling 
agent or maker.

4. Storage

Remove the screw retaining the battery compartment 
cover using a screwdriver.
Remove the battery compartment cover and take out the 
exhausted batteries.
Insert new batteries without mistaking the + and – polarity.
Attach the battery compartment cover and clamp it with the screw.

3. Battery replacement 

Replacement Procedure:

For calibration and inspection of the instrument, please 
contact dealer, sole agent and maker.

2. Calibration

Instructions

1. Maintenance check
1) External finish

2) Light sensor

Check if the external finish is damaged by dropping the 
instrument, etc.

Check if the light sensor surface is damaged.
Check if the light sensor cord is damaged.
If any of the above parts is damaged, do not use the instrument 
but have it repaired.


1

2

3
4



Design and specifications are subject to change for reasons of 
improvement, etc.

Dempa Bldg, Sotokanda 2-Chome,Chiyoda-ku, Tokyo, Japan
TEL.: 81-3-3251-0941  FAX.: 81-3-3256-9740
Web site: www.sanwa-meter.co.jp
e-mail: [email protected]