9
8
3.5
Assembly of the alkaline outlet hose and the acidic water tap
3.6
Before use
3.7
Language settings
3.8
Control of the ionization performance
•
Screw the alkaline outlet hose (A-2) to
the upper water outlet (B-5).
•
Connect the plastic hose for acidic
water 7/9 mm (A-4) to the lower water
outlet (B-12) and the acidic water tap
(A-3).
•
The appliance requires a 230V (US model 120V) power supply.
•
The appliance switches on automatically when the water supply is opened.
•
Pressure adjustment: Adjust the water pressure so that the bars are in the „normal“
range.
Note
: The ECAIA ionizer S is only suitable for cold drinking water!
For language settings, refer to the complete instruction manual.
You can check the ionization performance by measuring the pH value. To do this, use the
indicator liquid supplied together with the pH scale (A-8).
For 5 to 10 milliliters of test water you need 1-2 drops of indicator liquid.
Ideally, the water should turn purple (pH 9 to 9.5) in the range of alkaline levels 3 or 4. If
this is not the case, you will fi nd further setting options in the complete instruction manual.
EN
Содержание ECAIA ionizer S
Страница 2: ...2 ECAIA ionizer S items included in the scope of delivery 1 2...
Страница 72: ...72 3 1 3 1 A 9 2 A 6 A 9 B 11 3 B 3 ECAIA ionizer S 3 2 1 A 6 1 cm 2 A 11 3 A 6 A 11 A 6 BG...
Страница 75: ...75 A 2 ALKALINE 1 5 pH 8 5 9 5 ACID 1 2 A 2 A 3 PURIFY 6 999 6 4 ECAIA 5 6 BG...
Страница 96: ...96 3 1 3 1 A 9 2 A 6 A 9 B 11 3 B 3 ECAIA ionizer S 3 2 1 A 6 1 2 A 11 3 A 6 A 11 A 6 EL...
Страница 99: ...99 A 2 ALKALINE 1 5 pH 8 5 9 5 ACID 1 2 A 2 A 3 PURIFY 6 999 6 4 ECAIA 5 6 EL...