User manual SNC-P3601M
_________________________________________________________________________________
- 31 -
3.8.2. Alarm settings
Alarm in (sensor):
Activate/deactivate the alarm input
o
Active type
“low”: This means 0 V. The camera will trigger an alarm if the alarm input
has 0 V. To achieve 0 V at the alarm input, the contacts are closed.
o
Active type „high“: This means 3.3 V. The camera will trigger an alarm if the alarm
input has 3.3 V. To achieve 3.3 V at the alarm input, the contacts are not closed.
Alarm out (relay):
Activate/deactivate the alarm output
o
Active type „low“: This means 0 V. If the camera triggers an alarm, the alarm output
has 0 V.
o
Active type „high“: This means 3.3 V. If the camera triggers an alarm, the alarm
output has 3.3 V.
o
Trigger an alarm when Ethernet is lost:
The camera can trigger an alarm if the network
connection is interrupted.
Alarm relay duration:
You can set how long the alarm output should be active since the
alarm is not being triggered anymore.
o
0 second: The alarm output is set to inactivity immediately after the alarm.
o
10 seconds: The alarm output is set to inactivity 10 seconds after the alarm.
o
30 seconds: The alarm output is set to inactivity 30 seconds after the alarm.
o
1 minute: The alarm output is set to inactivity 1 minute after the alarm.
o
Endless: The alarm output remains active until the alarm output is manually set to
inactivity (press button
on the “live view” page of the web interface).
Submit:
Click here to save the new alarm settings.