Sanremo SR405 Скачать руководство пользователя страница 1

 16 

FOREWORD

This instruction manual contains information and advice on the upkeep and how to get the best out of 
your coffee machine.
Before using the appliance all the indications in this manual must be read and rigorously observed to 
ensure the optimum performance and duration of your coffee machine, considering the user instructions 
as an integral part of the appliance and therefore keeping them for its whole duration.

TECHNICAL DETAILS

WARNINGS

- The appliance must not be cleaned using solvents, thinners, spirits, etc. The use of warm water and 

neutral detergent with a soft cloth are ideal to maintain the external and internal parts in good condi-
tion.

- The appliance must not be cleaned using a water jet.

- Do not put the appliance in water

- Since the appliance produces heat it should be kept in a cool location with the best ventilation possible, 

for instance do not position it next to a radiator.

- The appliance is unsuitable for outdoor installation

- To ensure safe use the appliance not must be placed on a slope greater than 3°

- If the power cable is damaged, have it replaced by an After-Sales Service Centre, since a special tool 

is required for this purpose.

- Before any maintenance ALWAYS unplug the mains power cable.

- Only connect to an adequately earthed electrical plant.

- Keep the appliance away from children

The manufacturer and the distributor shall not be under any liability for malfunctions in 
the appliance,

 injury to persons and animals or damage to property arising from failure to comply with 

part or all of the warnings or instructions given in this manual and from improper, incomplete or negli-
gence in maintenance and/or cleaning.

All technical assistance and maintenance can only be carried out by specialists authorised by the sup-
plier of the coffee machine.

ENGLISH

Width

mm

230

Depth

mm

347

Height

mm

407

Reservoir capacity

l

3.4

Net weight SR405

kg

13.7

Net weight SR405 Steam

kg

14.6

Voltage

V

220-240~

Coffee exchanger heating element input

W

800

Steam exchanger heating element input

W

1000

Electric pump input

W

48

Steam micro-pump input

W

16

Solenoid valve input in SR405

W

27

Solenoid valve input in SR405 V

W

36

Содержание SR405

Страница 1: ...use the appliance not must be placed on a slope greater than 3 If the power cable is damaged have it replaced by an After Sales Service Centre since a special tool is required for this purpose Before any maintenance ALWAYS unplug the mains power cable Only connect to an adequately earthed electrical plant Keep the appliance away from children The manufacturer and the distributor shall not be under...

Страница 2: ... data on the rating plate correspond to your mains electricity supply e g 230 Volts etc 7 Plug the power cable Q into the mains socket 8 Switch the rear power switch P of the appliance to I 9 Wait for the green light C to go out before dispensing for the first time to ensure that the correct temperature has been reached USER INSTRUCTIONS A Orange LED Power indicator lights up to indicate the power...

Страница 3: ...sure that there are no pods inside the machine at the end of the day by expelling the last one using the provided empty pod fig 3 The empty pod should obviously not be thrown away but recovered and reused after being properly cleaned fig 1 fig 2 fig 3 HOT WATER Place a cup under the hot water tube G Press the hot water button D and wait for the desired quantity to be reached Press the hot water bu...

Страница 4: ...ff switch on the rear of the appliance in position 0 No coffee check that the drip pod tray is not too full If it is empty it check that the red light B is not on If it is fill up the tank The flap F does not fully close check that the drip pod tray is not too full If it is empty it The drip pod tray cannot be removed the tray is too full of pods pull out the tray by one centimetre and using a scr...

Страница 5: ...ATER CIRCUIT DIAGRAM SR405 WIRING DIAGRAM SR405 1 On off switch 2 Power on light 3 No water light 4 3 way solenoid valve 5 3 way solenoid valve 6 Pump 7 2 way solenoid valve 8 Heating element 9 Temperature indicator light 10 95 automatic thermostat 11 125 manual reset thermostat 12 Water switch 13 Coffee switch 14 No water microswitch ENGLISH ...

Страница 6: ...On off switch 2 Power on light 3 No water light 4 3 way solenoid valve 5 3 way solenoid valve 6 Pump 7 2 way solenoid valve 8 Coffee exchanger heating element 9 Temperature indicator light 10 95 automatic thermostat 11 125 manual reset thermostat 12 Water switch 13 Coffee switch 14 No water microswitch 15 Pump microswitch 16 3 way solenoid valve 17 Steam exchanger heating element 18 Steam switch 1...

Страница 7: ...22 SR405 EXPLODED ENGLISH ...

Страница 8: ...23 SR405 EXPLODED ENGLISH ...

Страница 9: ... WASHER ZN 49 10853210 RAPID L CONNECTION 4x1 8 M 50 10102205 THERMOSTAT CABLE 51 10111033 95 AUTOMATIC THERMOSTAT 52 10115030 125 THERMOSTAT MANUAL RESET 53 10040043B SEPARATE EXCHANGER 54 10024220 LOWER CAPSULE GUIDE 55 10852022 2611 1 8 M STOPPER 56 10853204 STRAIGHT RAPID CONNECTION 4x1 8M 57 10023252 SPOUT COVER TUBE 58 10303010A 2 WAY 230V SOLENOID VALVE 59 10852210 L CONNECTION 1 8 M F 60 1...

Страница 10: ...25 SR405V EXPLODED ENGLISH ...

Страница 11: ...26 SR405V EXPLODED ENGLISH ...

Страница 12: ...E 62 10853223 T CONNECTION 1 8 M M F 63 10809019 ZNN TBEI M3x8 SCREWS 64 10303021 3 WAY 230V SOLENOID VALVE POS CODE DESCRIPTION 65 10853070 L SHAPED RUBBER CONNECTION 66 10011524 L SHAPED PUMP SUPPORT 67 10255016 EP4 230V PUMP 68 10255040 THERMO PROTECTOR 69 10809002 FLAT D6 4X24X2 ZN WASHER 70 10805114 TC SW M5x12 ZN SW SCREWS 71 10023290 DIE CAST UPPER DISK 72 10503018 PISTON UNIT GASKET 73 105...

Отзывы: