Status Display Mode
During selection of an operation command from an external terminal or from communication through the function
code, as the key is pressed and held for about 2 seconds, running operation can be carried out instantly by the
operation panel.
Each time the key is pressed, the [operation command from the operation panel] and the [operation command
from an external terminal or communication] will be interchanged.
Control authorization is indicated by a lit lamp where the running operation is controlled by operation panel.
Table 5-5 Control authorization displays
Operation Command
Control authorization display
Operation Panel
External
terminal
/
communication
Lit
Flashing
Unlit
*See the function code F1101 of the operation command from an external terminal / operation command from communication.
*Sometimes this function is not available if set through the inverter’s function code.
5-3-3
Alarm display
When the alarm has stopped, the type of alarm will be displayed on the 7-segment monitor of the inverter. At this point,
the monitor mode displays that all the LEDs are flashing. See [8-4 Alarm Status] for the details of alarm display.
Display Contents
Monitor mode display
7-segment
Monitor
Displays
Alarm display
Hz
A
rpm
%
M
The type of an
alarm is
indicated by the
lit lamp
Lit
Flashing
Unlit
*During alarm display, the display on 7-segment monitor can not be switched even by pressing key or
key.
*During alarm display, pressing
key can switch current display to function code display mode.