KSwitch R3 UMP Unmanaged PoE Ethernet Switch - Preliminary User Guide, Rev. 0.9 

 

www.kontron.com 

 

// 13 

 

2/

 

General Safety Instructions 

Please read this passage carefully and take careful note of the instructions, which have been compiled for your safety 
and to ensure to apply in accordance with intended regulations. If the following general safety instructions are not 
observed, it could lead to injuries to the operator and/or damage of the product; in cases of non-observance of the 
instructions Kontron Europe is exempt from accident liability, this also applies during the warranty period. 

The product has been built and tested according to the basic safety requirements for low voltage (LVD) applications 
and has left the manufacturer in safety-related, flawless condition. To maintain this condition and to also ensure safe 
operation, the operator must not only observe the correct operating conditions for the product but also the following 
general safety instructions:  

 

The product must be used as specified in the product documentation, in which the instructions for safety for the 
product and for the operator are described. These contain guidelines for setting up, installation and assembly, 
maintenance, transport or storage. 

 

The on-site electrical installation must meet the requirements of the country's specific local regulations. 

 

If a power cable comes with the product, only this cable should be used. Do not use an extension cable to connect 
the product. 

 

To guarantee that sufficient air circulation is available to cool the product, please ensure that the ventilation 
openings are not covered or blocked. If a filter mat is provided, this should be cleaned regularly. Do not place the 
product close to heat sources or damp places. Make sure the product is well ventilated. 

 

Only connect the product to an external power supply providing the voltage type (AC or DC) and the input power 
(max. current) specified on the Kontron Product Label and meeting the requirements of the Limited Power Source 
(LPS) and Power Source (PS2) of UL/IEC 62368-1 . 

 

Only products or parts that meet the requirements for Power Source (PS1) of UL/IEC 62368-1 may be connected 
to the product’s available interfaces (I/O). 

 

Before opening the product, make sure that the product is disconnected from the mains.  

 

Switching off the product by its power button does not disconnect it from the mains. Complete disconnection is 
only possible if the power cable is removed from the wall plug or from the product. Ensure that there is free and 
easy access to enable disconnection. 

 

The product may only be opened for the insertion or removal of add-on cards (depending on the configuration of 
the product). This may only be carried out by qualified operators.  

 

If extensions are being carried out, the following must be observed:   

 

all effective legal regulations and all technical data are adhered to 

 

the power consumption of any add-on card does not exceed the specified limitations  

 

the current consumption of the product does not exceed the value stated on the product label.   

 

Only original accessories that have been approved by Kontron Europe can be used.  

 

Please note: safe operation is no longer possible when any of the following applies: 

 

the product has visible damages or 

 

the product is no longer functioning 
In this case the product must be switched off and it must be ensured that the product can no longer be 
operated. 

 

Handling and operation of the product is permitted only for trained personnel within a work place that is access 
controlled. 

 

CAUTION:  Risk of explosion if the battery is replaced incorrectly (short-circuited, reverse-poled, wrong battery 
type). Dispose of used batteries according to the manufacturer’s instructions. 

 

This product is not suitable for use in locations where children are likely to be present 

 

Additional Safety Instructions for DC Power Supply Circuits 

 

To guarantee safe operation, please observe that:  

 

the external DC power supply must meet the criteria for LPS and PS2 (UL/IEC 62368-1)  

 

no cables or parts without insulation in electrical circuits with dangerous voltage or power should be 
touched directly or indirectly  

 

a reliable protective earthing connection is provided  

Содержание Kontron KSwitch R3 UMP Series

Страница 1: ...USER GUIDE www kontron com KSwitch R3 UMP Unmanaged PoE Ethernet Switch Doc Preliminary User Guide Rev 0 9 Doc ID 1068 1430...

Страница 2: ...KSwitch R3 UMP Unmanaged PoE Ethernet Switch Preliminary User Guide Rev 0 9 www kontron com 2 This page has been intentionally left blank...

Страница 3: ...warranty that such application will be suitable for the specified use without further testing or modification Kontron expressly informs the user that this user guide only contains a general descripti...

Страница 4: ...Applications is entirely at your risk To minimize the risks associated with your products and applications you should provide adequate design and operating safeguards You are solely responsible for co...

Страница 5: ...ontacts by visiting https www kontron com support and services kontron europe and asia support contact support Customer Service As a trusted technology innovator and global solutions provider Kontron...

Страница 6: ...indicated and or prescribed by the law may endanger your life health and or result in damage to your material ESD Sensitive Device This symbol and title informs that the electronic boards and their c...

Страница 7: ...n of piggybacks Serious electrical shock hazards can exist during all installation repair and maintenance operations on this product Therefore always unplug the power cable and any other cables which...

Страница 8: ...circuits and damage the batteries or conductive circuits on the product Lithium Battery Precautions If your product is equipped with a lithium battery take the following precautions when replacing the...

Страница 9: ...ponents used are capable of being recycled Final disposal of this product after its service life must be accomplished in accordance with applicable country state or local laws or regulations WEEE Comp...

Страница 10: ...Packaging 15 3 1 Packaging 15 3 2 Unpacking 15 3 3 Scope of Delivery 15 3 4 Accessories 15 3 5 Product Identification Type Label 17 4 Features 18 4 1 Faceplate Features 19 4 1 1 RJ45 Copper PoE Ethern...

Страница 11: ...cal Specification 27 Table 9 Electrical Specification 29 Table 10 List of Acronyms 33 List of Figures Figure 1 Type Label 17 Figure 2 KSwitch R3 UMP Unmanaged PoE Ethernet Switch 18 Figure 3 RJ45 Copp...

Страница 12: ...of this user guide visit Kontron s KSwitch Industrial Ethernet switches at https www kontron com products systems ethernet solutions This user guide provides an overview of the switch s features and...

Страница 13: ...Power Source LPS and Power Source PS2 of UL IEC 62368 1 Only products or parts that meet the requirements for Power Source PS1 of UL IEC 62368 1 may be connected to the product s available interfaces...

Страница 14: ...connector attached to a broken fiber or an energized fiber 2 2 Electrostatic Discharge ESD A sudden discharge of electrostatic electricity can destroy static sensitive devices or micro circuitry There...

Страница 15: ...order contact Kontron for help and information 3 3 Scope of Delivery Check that your delivery is complete and contains the items listed below If you discover damaged or missing items contact your deal...

Страница 16: ...0 Megabit SFP Modules 100BaseF X ps multi mode transceiver 2km 850nm wide operating Temp 40 85 C EN SFP F M004 T 100 Megabit SFP Modules 100BaseF X ps multi mode transceiver 5km 1310nm wide operating...

Страница 17: ...kontron com 17 3 5 Product Identification Type Label Figure 1 Type Label 1 Model full name 2 Series name 3 Part Number PN with bar code 4 Revision 5 Serial Number SN with barcode 6 Production date 7 E...

Страница 18: ...Ethernet ports where 2 ports support Gigabit TX or FX and up to 24 ports are PoE IEEE 802 3af at compatible with up to 30 W power output Figure 2 KSwitch R3 UMP Unmanaged PoE Ethernet Switch Key feat...

Страница 19: ...rnet Ports 10 port 18 port 26 port Table 3 Ethernet Ports RJ45 copper Connector Pin Assignment Pin Signal PoE Assignment 1 2 T Rx T Rx Positive Vport 3 6 R Tx R Tx Negative Vport 4 5 T Rx T Rx X 7 8 T...

Страница 20: ...For each fiber port there is a transmit TX and receive RX signal When making fiber optic connections ensure that the transmit TX port of the switch connects to the receive RX port of the other device...

Страница 21: ...ected PWR1 PWR2 PWR3 Red On Green Power line has power Off Power line disconnect or does not have supply power RJ45 Copper 10 100 MbpS Link Act Yellow On Yellow Ethernet link up but no traffic is dete...

Страница 22: ...o avoid accidental removal of the power cable after inserting the power cable close the lock lever The switch s total power budget depends on the number of power connections with 250 W 10 port 490 W 1...

Страница 23: ...wo rack mount brackets front or rear are used exclusively to lock the switch in position on the cabinets support frame and do not physically hold the switch Figure 7 Sides left and right 4 4 Bottom Si...

Страница 24: ...brackets front or rear are used exclusively to lock the switch in position on the cabinets support frame and do not physically hold the switch Figure 9 Rack Mounting 1 Two rear side brackets 2 Two fro...

Страница 25: ...e cut off fixture To connect the switch to a power supply and turn on perform the following 1 Connect a 3 pin IEC 320 power cable to each power connector s on the rear side of the switch 2 Connecting...

Страница 26: ...2x 1000 Base SFP slot RJ45 Copper Ports Speed Up to 24x 10 100 Mbps plus optional 2x 10 100 1000 Mbps MDI MDIX Auto Crossover Support straight or cross wired cables Auto Negotiation Duplex 10 100 100...

Страница 27: ...rtification 10 Port 18 port 26 port EMC EN 61000 6 3 Class B EN 61000 6 4 EN 61000 6 2 and EN 55035 Safety UL IEC EN 62368 1 FCC According to requirements of 47 CFR FCC Part 15 Subpart B Class A rules...

Страница 28: ...KSwitch R3 UMP Unmanaged PoE Ethernet Switch Preliminary User Guide Rev 0 9 www kontron com 28 Figure 10 Mechanical Dimensions 10 port Figure 11 Mechanical Dimensions 18 port...

Страница 29: ...ort 18 port 26 port Input Voltage range 1x 100 VAC 240 VAC 50 Hz 60 Hz 2x 100 VAC 240 VAC 50 Hz 60 Hz 3x 100 VAC 240 VAC 50 Hz 60 Hz Current 1x 0 3 A max 2x 0 3 A max 3x 0 3 A max PoE IEEE802 3af at 8...

Страница 30: ...nance or repair on the switch may only be carried out by qualified personnel authorized by Kontron Return the KSwitch R3 UMP to Kontron for maintenance and repair see Chapter 9 1 Returning Defective M...

Страница 31: ...ty period Follow these steps before returning any product to Kontron 1 Visit the RMA Information website http www kontron com support and services support rma information Download the RMA Request shee...

Страница 32: ...atutory accident liability obligations in the event of damage caused to the product due to failure to observe the following General safety instructions for IT equipment within this user guide Warning...

Страница 33: ...e LPS Limited Power Source MAC Media Access Control MDI Medium Dependent Interface MDIX Medium Dependent Interface cross over MIB Management Information Base MLD Multicast Listener Discovery MSTI Mult...

Страница 34: ...Industry 4 0 applications With its standard products and tailor made solutions based on highly reliable state of the art embedded technologies Kontron provides secure and innovative applications for a...

Отзывы: