background image

KBox C-103-CFL-x  - User Guide, Rev. 1.0 

 

www.kontron.com 

 

// 52 

 

6.3.

 

Internal View 

Figure 39: KBox C-103-CFL-2 - internal view (shown with a PCIe riser card and removable HDD/SSD drive bay) 

 

1

 

Cover retaining bracket on the front side 

2

 

Screws that secure the PCIe slot brackets 

3

 

Internal USB 3.0 port with USB cable connected 

4

 

Optional GPIO module, connected to  
internal USB 3.0 port via cable 

5

 

PCI x8 socket of the baseboard 

6

 

Riser card with 1x PCIe x8 socket 

7

 

Mounting frame for 2.5" drive bays of the 
removable HDDs/SSDs 

8

 

Lower mounting bracket with key holes 

9

 

SATA cable connections (power and data) 

10

 

Baseboard 

11

 

3x M.2 sockets (2x Type B, 1x Type M), 
left socket (J13) with wireless module installed 

12

 

Threaded holes/fixing bolts to secure the 3x M.2 
modules  

13

 

Cover retaining bracket on the rear side 

14

 

 Cooling fins 

15

 

Upper mounting bracket with key holes 

 

 

 

The Mini PCIe socket is on the lower side of the baseboard and can be only at factory 
equipped with an expansion card. 

15 

13 

11 

10 

14 

12 

Содержание Kontron KBox C-103-0

Страница 1: ...USER GUIDE www kontron com 1 KBox C 103 CFL x User Guide Rev 1 0 Doc ID 1067 5219 KBox C 103 CFL 4 KBox C 103 CFL 2 KBox C 103 CFL 1 KBox C 103 CFL 0...

Страница 2: ...KBox C 103 CFL x User Guide Rev 1 0 www kontron com 2 This page has been intentionally left blank...

Страница 3: ...ll be suitable for the specified use without further testing or modification Kontron expressly informs the user that this user guide only contains a general description of processes and instructions w...

Страница 4: ...uld provide adequate design and operating safeguards You are solely responsible for compliance with all legal regulatory safety and security related requirements concerning your products You are respo...

Страница 5: ...port Find Kontron contacts by visiting http www kontron com support Customer Service As a trusted technology innovator and global solutions provider Kontron extends its embedded market strengths into...

Страница 6: ...rescribed by the law may endanger your life health and or result in damage to your material ESD Sensitive Device This symbol and title inform that the electronic boards and their components are sensit...

Страница 7: ...ges before performing any work on this product Earth ground connection to vehicle s chassis or a central grounding point shall remain connected The earth ground cable shall be the last cable to be dis...

Страница 8: ...product then re pack it in the same manner as it was delivered Special care is necessary when handling or unpacking the product See Special Handling and Unpacking Instruction Quality and Environmenta...

Страница 9: ...Unpacking 19 3 1 Unpacking 19 3 2 Scope of Delivery 19 3 2 1 Optional Parts System Expansion 19 3 2 2 Optional System Extension 19 3 3 Spare Parts 20 3 4 Type Label and Product Identification 20 4 Sys...

Страница 10: ...ox C 103 CFL 4 2 1 46 5 10 1 Fan Tray only for KBox C 103 CFL 4 2 1 47 6 Accessing Internal Components 48 6 1 Top Cover 49 6 2 Opening and Closing the KBox C 103 CFL 50 6 3 Internal View 52 6 3 1 Inte...

Страница 11: ...97 11 5 1 Updating Procedure 97 11 5 2 uEFI BIOS Recovery 97 11 5 3 Determining the Active Flash 97 12 Technical Specifications 98 12 1 Mechanical Specifications of the KBox C 103 CFL 100 12 1 1 Mecha...

Страница 12: ...ys Available in the Legend Bar 77 Table 16 Main Setup Menu Sub screens and Functions 79 Table 17 Advanced Setup menu Sub screens and Functions 81 Table 18 Chipset System Agent Configuration Sub screen...

Страница 13: ...ure 23 Top side of the KBox C 103 CFL system 36 Figure 24 Bottom side of the KBox C 103 CFL system 36 Figure 25 Rear side of the KBox C 103 CFL 2 system 37 Figure 26 KBox C 103 CFL 4 shown with option...

Страница 14: ...igure 71 Dimensions top side KBox C 103 CFL 4 100 Figure 72 Dimensions right side KBox C 103 CFL 4 with fan tray option 101 Figure 73 Dimensions front side with key holes KBox C 103 CFL 4 with fan tra...

Страница 15: ...on comes with the product only this cable should be used to supply the product Do not use an extension cable to connect the product To guarantee that sufficient air circulation is available to cool th...

Страница 16: ...e disconnecting device is used in the application e g overcurrent protective device if the device itself is not disconnectable a disconnect device if provided in or as part of the equipment shall disc...

Страница 17: ...Always handle electrostatically sensitive components by their edge or by their casing 4 Avoid contact with pins leads or circuitry 5 Turn off power and input signals before inserting and removing conn...

Страница 18: ...ion If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interfer...

Страница 19: ...y Instructions for Equipment 3 2 1 Optional Parts System Expansion Front accessible drive bays for 2 5 SATA HDD SSDs M 2 cards PCIe cards USB Dongles 3 2 2 Optional System Extension RS232 RS422 Port v...

Страница 20: ...9 Figure 1 Example of KBox C 103 CFL type label Table 2 Product Identification Table System Type Product Designation Product Identifikation KBox C KBox C 103 CFL KBox C 103 CFL 4 corresponds for syst...

Страница 21: ...rd IO interfacing plus a comprehensive optionally available IOs and devices The KBox C 103 CFL offers a maintenance free wartungsfrei operation That means it operates without battery fans and rotating...

Страница 22: ...Optional fan tray not possible for KBox C 103 CFL 0 Profibus Profinet or Ethercat Fieldbus support via internal factory mounted adapter module X201 X206 LTE via internal factory mounted adapter module...

Страница 23: ...TC buffer time depending on temperature If the time is not valid this is indicated by a status bit in the RTC registers For details see the RV 8803 C7 application manual To get the maximum buffer time...

Страница 24: ...e Mini PCIe interface connector is located on the lower side of the baseboard and is not accessible in the field This interface connector is intended to be used for Fieldbus or WiFi expansion If a cus...

Страница 25: ...nstallation of 2 5 SATA HDD SSD devices for each system of the KBox C 103 CFL family refer to the area marked D in the section 4 4 Refer to chapter 12 Technical Specifications and the descriptions in...

Страница 26: ...gure 10 Views of a KBox C 103 CFL 2 Figure 4 Bottom side view Figure 5 Right side view Figure 6 Front side view config with removable drives Figure 7 Front side view config without removable drives Fi...

Страница 27: ...Side of KBox C 103 CFL 2 with cooling fins 2 Top side cover with knurled screws TH DR M2 WD GP1 GP2 GP3 GP4 PCIe Slot 1 2 Drive 1 2 SATA HDD SSD drive bays PWR Button LED RSQ Button LED X104 X107 X110...

Страница 28: ...KBox C 103 CFL x User Guide Rev 1 0 www kontron com 28 Figure 12 Block Diagram KBox C 103 CFL x...

Страница 29: ...N Port X204 1x 1x 1x 1x 2nd RS232 RS422 Port X205 1x 1x 1x 1x WideLink X202 or 3rd DisplayPort X203 1x 1x 1x 1x 2nd Power Input Connector X201 1x 1x 1x 1x LTE on M 2 3042 ANT1 ANT2 1x 1x 1x 1x C PCI P...

Страница 30: ...terfaces X102 optionally provides a PoE Power over Ethernet option the PoE module has to be developed on project base The connectors are standard 8 pin RJ45 type connectors with status LEDs Activity l...

Страница 31: ...n four seconds a forced system shutdown will be initiated before the power to the system is turned off Caution Performing a forced shut down can lead to loss of data or other undesirable effects The p...

Страница 32: ...revert to using the standard boot flash the system must be cold started or remove power completely from the system and then reapply 4 5 9 Status and General Purpose LEDs After power is applied and the...

Страница 33: ...the right side access cover Figure 23 and Figure 21 pos 1 and pos 3 also Figure 17 PCIe 1 to PCIe 4 slots shown as detail of a KBox C 103 CFL 4 Please observe that KBox C 103 CFL 4 supports up to 2x P...

Страница 34: ...RIVE 1 and DRIVE 2 for removable SATA HDDs SSDs are not available refer to Figure 7 If the KBox C 103 CFL 2 configuration with removable 2 5 SATA HDDs SSDs was ordered no installation of any internal...

Страница 35: ...rform the following steps 1 Pull out the lever Figure 19 pos 3 of the drive cover Figure 18 pos 2 and release it If required unlock the lever with the corresponding key before 2 The drive bay cover wi...

Страница 36: ...the cooling fins to the chassis 9 Type label 10 Hole for further system fan tray extension 11 Air intake openings on the bottom cover 12 Air exhaust openings on the top cover Please do not remove the...

Страница 37: ...Functional Earth Stud There is an M4 functional earth terminal on the lower mounting bracket of the KBox C 103 CFL Figure 25 pos 6 This terminal may be connected as required The KBox C 103 CFL with t...

Страница 38: ...s Profinet or Ethercat via internal factory mounted adapter module Second 24 VDC input X201 GPIO module You have to order these components separately in order to extend your KBox C 103 CFL at the fact...

Страница 39: ...put Profibus WideLink 3rd DP port CAN 2nd Serial Profinet Ethercat WiFI X201 X201 X202 X203 X204 X205 X206 X206 2nd Power Input X201 No Yes Yes Yes Yes Yes Yes Profibus X201 No Yes Yes Yes Yes No No W...

Страница 40: ...termination resistor 120 If your application requires the termination resistor it must be enabled at factory only For pin assignment refer to subsection 13 2 4 5 3 LTE M 2 module The KBox C 103 CFL c...

Страница 41: ...for Profibus or the dual RJ45 brake out X206 for Profinet Ethercat will be used Only one of these two Fieldbus interfaces D Sub or dual RJ45 can be ordered as optional extension of your KBox C 103 CF...

Страница 42: ...C Input Your KBox C 103 CFL can optionally be extended with a second power input module X201 Both power connectors have the same pinout The power source with the highest input voltage will be used to...

Страница 43: ...Pin Signal Name Direction Remark 1 PWR_IN Power Power Input for the GPIO 2 PWR_IN Power 3 Not Connected n c 4 GPIO1 In Out GPIO 5 GPIO2 In Out 6 GPIO3 In Out 7 GPIO4 In Out 8 GPIO5 In Out 9 GPIO6 In O...

Страница 44: ...A Inductive load switch off energy dissipation 40mJ Output Protection Short to GND Protection by Current Limit Thermal Shutdown with Output auto retry Inductive Load Negative Voltage Clamp Figure 30 O...

Страница 45: ...Cycles Remark Connector W rth Elektronik or equivalentent 691382040012 WR TBL Serie 382 or equivalent 25 12 pin 2 50 mm Horizontal PCB Header with Flanges Max 12A per pin Mating Connector W rth Elektr...

Страница 46: ...d comprises a fan tray Figure 32 pos 1 with one fan as well as the air filter Figure 32 KBox C 103 CFL 1 equipped with the optional fan tray The fan is integrated in a user friendly replaceable fan tr...

Страница 47: ...only be carried out by qualified personnel aware of the associated dangers see subsection 10 3 Replacing the Fan Tray Figure 33 Fan tray components of the KBox C 103 CFL 4 2 1 cable connections betwe...

Страница 48: ...system shall be mounted into a control cabinet Only personnel with appropriate qualifications trainings and authorization are permitted to install and work with the KBox C 103 CFL system The installa...

Страница 49: ...r will be fixed to the chassis using the centring bracket at the rear side of the cover Figure 34 pos 3 and the fixing bracket with captive knurled screws at the front side of the cover Figure 34 pos...

Страница 50: ...Box C 103 CFL Please observe the instructions contained in the chapter 8 Installation Instructions 1 Close all applications Shut down the system properly and disconnect the connection to the power sou...

Страница 51: ...r out to detach it from the sideways mounted bolts Put the right side cover and the screws aside for later use Figure 38 KBox C 103 CFL 2 without top and right side cover shown with a PCIe riser card...

Страница 52: ...baseboard 6 Riser card with 1x PCIe x8 socket 7 Mounting frame for 2 5 drive bays of the removable HDDs SSDs 8 Lower mounting bracket with key holes 9 SATA cable connections power and data 10 Baseboa...

Страница 53: ...x8 socket 7 Cover retaining plate on the rear side 8 Threaded holes fixing bolts to secure the 3x M 2 modules 9 Upper mounting bracket with key holes 10 microSD microSIM combo connector 11 Cooling fi...

Страница 54: ...d up to four PCIe x4 PCIe x1 cards full height half length form factor via corresponding riser cards For installation removing of PCI PCIe cards into from the corresponding socket Figure 42 pos 5 and...

Страница 55: ...table shows which riser card is available for which system Table 12 Available Riser Cards for the different KBox C 103 CFL variants KBox C 103 CFL 4 KBox C 103 CFL 2 KBox C 103 CFL 1 2x PCIe x4 1x Gen...

Страница 56: ...form factor The riser card provides an extra power connector for add on cards with high power consumption and a card present jumper for each slot If an installed add on card is not automatically dete...

Страница 57: ...to open the KBox C 103 CFL 4 2 1 as described in the section 6 2 Opening and Closing the KBox C 103 CFL step 1 6 3 To remove install an expansion card you have to remove the corresponding card slot b...

Страница 58: ...PCIe 2 slot 9 Slot bracket for the for the PCIe 3 expansion slot 10 Slot bracket for the for the PCIe 4 expansion slot 11 Riser card with 2x PCIe x4 and 2x PCIe x1 expansion sockets 12 Free PCIe x1 s...

Страница 59: ...screw 7 In order to close the KBox C 103 CFL proceed in reverse order step 6 to 1 of the section 6 2 To remove an M 2 module please proceed according to the steps described 1 Close all applications s...

Страница 60: ...t a microSIM card into the the microSIM connector or and insert a microSD card int the microSD connector by gently pushing the card into the corresponding connector card contacts facing down see Figur...

Страница 61: ...ystem internal components 7 4 Minimum System Clearance To provide a maximum of airflow through and around the box minimum distances to surrounding parts must be observed please refer to the subsection...

Страница 62: ...d party components like PCIe extension cards and drives HDD or SSD it has to be taken into account that the air temperature inside the system is higher than the ambient temperature An approximately in...

Страница 63: ...igned to be operated in vertical position with attached mounting brackets as shown in Figure 6 and Figure 7 It is not allowed to install the KBox C 103 CFL as a stand alone desktop device Do not remov...

Страница 64: ...bled mounting brackets The key holes of the upper and lower mounting brackets Figure 25 pos 1 and pos 3 allow you to mount the KBox C 103 CFL to a mounting side of the control cabinet in vertical posi...

Страница 65: ...Rev 1 0 www kontron com 65 Figure 46 Keep out area for mounting around KBox C 103 CFL 4 front side view without fan tray Figure 47 Keep out area for mounting around KBox C 103 CFL 4 front side view w...

Страница 66: ...ide Rev 1 0 www kontron com 66 Figure 48 Keep out area for mounting around KBox C 103 CFL 2 front side view without fan tray Figure 49 Keep out area for mounting around KBox C 103 CFL 2 front side vie...

Страница 67: ...ide Rev 1 0 www kontron com 67 Figure 50 Keep out area for mounting around KBox C 103 CFL 1 front side view without fan tray Figure 51 Keep out area for mounting around KBox C 103 CFL 1 front side vie...

Страница 68: ...KBox C 103 CFL x User Guide Rev 1 0 www kontron com 68 Figure 52 Keep out area for mounting around KBox C 103 CFL 0...

Страница 69: ...inserting the 0V wire 8 3 1 Cabling For the pin assignment Phoenix power plug terminal refer to the subsection 4 5 1 X101 X201 Power Input Connectors 1 Cut the required length three isolated wires 1 m...

Страница 70: ...s well as to the side wall mounting bracktes Prepare the mounting surface with four screws and if necessary anchors corresponding to the mounting surface type fire resistant material Please refer to t...

Страница 71: ...the KBox C 103 CFL Even when the system is turned off via the power button Figure 11 and Figure 15 marked PWR parts of the system are still energized The disconnecting device fuse circuit backer ratin...

Страница 72: ...tton and PWR LED Do not disconnect the power from your system while it is powered up Performing a forced shutdown can lead to loss of data or other undesirable effects 9 3 Operating System and Hardwar...

Страница 73: ...ithium battery CR 2032 3V internally accessible and you have to replace it please proceed as follows 1 Open the topside access cover as describes in chapter 6 2 Opening and Closing the KBox C 103 CFL...

Страница 74: ...96 for KBox C 103 CFL 4 Part number of the fan tray 9 5000 1095 for KBox C 103 CFL 2 Part number of the fan tray 9 5000 1094 for KBox C 103 CFL 1 The fan tray can be replaced during operation This sho...

Страница 75: ...e for later reassembly refer to step 2 and 3 in Figure 57 4 Remove the soiled air filter Figure 57 pos 3 and Figure 58 pos 6 5 Clean the air filter as follows 6 Rinse in water up to approx 40 C possib...

Страница 76: ...lter Figure 60 Holder shown for KBox C 103 CFL 2 with air filter Figure 61 Air filter shown for KBox C 103 CFL 2 1 KBox C 103 CFL assembled with the optional fan tray slot 2 Removed fan tray 3 Fan tra...

Страница 77: ...program follow the steps below 1 Power on the board 2 Wait until the first characters appear on the screen POST messages or splash screen 3 Press the DEL key 4 If the uEFI BIOS is password protected...

Страница 78: ...etup menus The currently active menu and the currently active uEFI BIOS Setup item are highlighted in white Each Setup menu provides two main frames The left frame displays all available functions Con...

Страница 79: ...nd Access level Board Information Read only field Board ID Fab ID LAN PHY Revision Processor Information Read only field Displays information about the CPU Name Type Speed Processor ID Stepping Packag...

Страница 80: ...d only subscreen Module Information Displays information about Product Name Revision Serial MAC Adress Boot Counter and CPLD Revision Carrier Board Information Displays information about Product Name...

Страница 81: ...ub Screen Function Second level Sub Screen Description RC ACPI PTID Support Enable Disable PECI Access Method Direct I O ACPI Native PCIE Enable Enable Disable Native ASPM Auto Enable Disable Wake Sys...

Страница 82: ...able Disable Package C State Limit Auto GT Power Management Control RC6 Render Standby Enable Disable Maximum GT frequency Default Max Frequency Disable Turbo GT frequency Enable Disable PCH FW Config...

Страница 83: ...on Enable Disable Enable Hibernation Enable Disable ACPI Sleep State S3 Suspend to RAM Suspend Disabled Lock Legacy Resources Enable Disable S3 Video Repost Enable Disable Miscellaneous Watchdog Auto...

Страница 84: ...ty Keypad VT100 LINUX XTERM6 SCO ESCN VT400 COM1 Console Redirection Enable Disable Legacy Console Redirection Redirection COM Port COM0 COM1 Resolution 80x24 80x25 Redirecion After POST Always Enable...

Страница 85: ...s also disabled Common actions for a watchdog trigger events Delay Reset and Watchdog signal only CPLD code allows for triggering NMI or SCI This needs programming of a predefined action inside the BI...

Страница 86: ...uch as Windows 10 and Linux If a legacy OS is used or a Windows or Linux system is run in legacy mode then this menu allows for detailed option settings Note a change in settings only come into effect...

Страница 87: ...n entering the Chipset Setup menu the screen lists two sub screen options System Agent PCH IO Entering the System Agent Configuration and PCH IO Configuration sub screens provides basic system informa...

Страница 88: ...EG Eval External Gfx Card Primary Display Configuration Internal Graphics Auto Disabled Enabled GTT Size 8 MB Aperture Size 256 MB DVMT Pre Allocated 32 M DVMT Total Gfx Mem 256 M EFP1 Type DP with HD...

Страница 89: ...A Enabled Disabled PCIe Root Port 9 opt NVMe PCI Expr Root Port 9 Enable Disable Connection Type Slot ASPM8 Disabled PME SCI Enable Disable Hot Plug Enable Disable PCIe Speed Auto Detect Timeout 0 Ext...

Страница 90: ...s Enable Disable HD Audio Subsystem Configuration HD Audio Enable Disable Serial IO Configuration SPIO Controller Enable Disable PCH LAN Controller Enable Disable Wake on LAN Enable Disable Serial IRQ...

Страница 91: ...unctions Function Description Administrator Password Sets administrator password User Password Sets user password If only the administrator s password is set then only access to setup is limited The p...

Страница 92: ...n passwords results in the user being locked out of the system If the system cannot be booted because the User Password or the Supervisor Password are not known see Chapter 11 5 Updating the uEFI BIOS...

Страница 93: ...ts before initiating the original default boot selection Bootup NumLock State Selects keyboard NumLock state Quiet Boot Enables disables Quiet Boot Fast Boot Enables disables boot with initialization...

Страница 94: ...es and Reset Resets system after saving changes Discard Changes and Reset Resets system setup without saving any changes Save Changes Saves changes made so far for any of the setup options Discard Cha...

Страница 95: ...ot order and is the first boot option by default 11 3 1 1 Entering the uEFI Shell To enter the uEFI Shell follow the steps below 1 Power on the board 2 Press the F7 key instead of DEL to display a cho...

Страница 96: ...artup script terminates then the default boot order is continued 11 4 2 Create a Startup Script Startup scripts can be created using the uEFI Shell built in editor edit or under any OS with a plain te...

Страница 97: ...flash being corrupted and therefore the board not starting up the board can be booted from the recovery SPI boot flash if the DIP switch SW1 switch 2 is set to ON For further information refer to the...

Страница 98: ...H Thermal LED DR HDD SSD status LED M2 M 2 Card status LED WD Watchdog status LED GP1 4 General purpose LEDs Interfaces front side accessible 4x Ethernet 10 100 1000 Mbit s 3x USB 3 0 3x USB 2 0 2x Di...

Страница 99: ...ini PCIe x1 2x PCIe x4 and 2x PCIe x1 1x M 2 B type 1x full half size Mini PCIe x1 2x PCIe x4 or 1x PCIe x8 or 1x PCI 32 bit and 1x PCIe x4 via corresponding riser card 1x M 2 B type 1x full half size...

Страница 100: ...the KBox C 103 CFL 12 1 1 Mechanical Specifications of the KBox C 103 CFL 4 Figure 68 Dimensions right side KBox C 103 CFL 4 Figure 69 Dimensions front side with key holes KBox C 103 CFL 4 Figure 70 D...

Страница 101: ...th Fan Tray Option Figure 72 Dimensions right side KBox C 103 CFL 4 with fan tray option Figure 73 Dimensions front side with key holes KBox C 103 CFL 4 with fan tray option Figure 74 Dimensions detai...

Страница 102: ...ht with mounting brackets 290 mm 11 42 with mounting brackets 324 mm 12 756 Width 195 mm 6 10 195 mm 6 10 Depth with mounting brackets 210 mm 8 26 with mounting brackets 210 mm 8 26 Weight without pac...

Страница 103: ...Mechanical Specifications of the KBox C 103 CFL 2 Figure 76 Dimensions right side KBox C 103 CFL 2 Figure 77 Dimensions front side with key holes KBox C 103 CFL 2 Figure 78 Dimensions detail key hole...

Страница 104: ...th Fan Tray Option Figure 80 Dimensions right side KBox C 103 CFL 2 with fan tray option Figure 81 Dimensions front side with key holes KBox C 103 CFL 2 with fan tray option Figure 82 Dimensions detai...

Страница 105: ...t with mounting brackets 290 mm 11 42 with mounting brackets 324 mm 12 756 Width 155 mm 6 10 155 mm 6 10 Depth with mounting brackets 210 mm 8 26 with mounting brackets 210 mm 8 26 Weight without pack...

Страница 106: ...Mechanical Specifications of the KBox C 103 CFL 1 Figure 84 Dimensions right side KBox C 103 CFL 1 Figure 85 Dimensions front side with key holes KBox C 103 CFL 1 Figure 86 Dimensions detail key hole...

Страница 107: ...h Fan Tray Option Figure 88 Dimensions right side KBox C 103 CFL 1 with fan tray option Figure 89 Dimensions front side with key holes KBox C 103 CFL 1 with fan tray option Figure 90 Dimensions detail...

Страница 108: ...ht with mounting brackets 290 mm 11 42 with mounting brackets 324 mm 12 756 Width 130 mm 5 12 130 mm 5 12 Depth with mounting brackets 210 mm 8 26 with mounting brackets 210 mm 8 26 Weight without pac...

Страница 109: ...09 12 1 7 Mechanical Specifications of the KBox C 103 0 Figure 92 Dimensions right side KBox C 103 0 Figure 93 Dimensions front side with key holes KBox C 103 0 Figure 94 Dimensions detail key hole KB...

Страница 110: ...C 103 0 Standard Version Height with mounting brackets 290 mm 11 42 Width 117 mm 4 61 Depth with mounting brackets 210 mm 8 26 Weight without packaging without expansions Approx 3 8 kg 8 37 lbs Chass...

Страница 111: ...EON E 2276ME 0 C to 60 C 32 F to 140 F All values apply to systems with fan tray KBox C 103 CFL 1 2 4 without fan tray not UL approved Storage Transit Temperature 40 C 75 C 40 F 167 F Relative Humidit...

Страница 112: ...301 893 V2 1 1 5 GHz RLAN Harmonised Standard covering the essential requirements of article 3 2 of Directive 2014 53 EU RF Spectrum Efficiency Spurious Emission 2014 53 EU Article 3 2 EN 300 328 V2 1...

Страница 113: ...nt Directive WEEE Directive Compliant with the Waste Electrical and Electronic Equipment WEEE directive to reduce waste of electrical and electronic equipment encourage recycling and environmental dis...

Страница 114: ...ments of Safety Extra Low Voltage SELV and Limited Power Source L P S of UL IEC 60950 1 or PS2 of UL IEC 62368 1 Ensure that the power supply is used according to the manufacturer s instructions Ensur...

Страница 115: ...ces and system memory expansion The external power supply must supply power to all configured components 12 4 3 Protective Earth Stud Bolt The protective earth stud bolt connects to the internal chass...

Страница 116: ...ctor 13 1 2 X102 X105 X108 X111 Ethernet Connectors Table 34 X102 X105 X108 X111 Ethernet Connectors Speed Mbps LINK ACT LINK ACTIVE 10 off on orange on blinking 100 green on orange on blinking 1000 o...

Страница 117: ...X104 X107 X110 USB 2 0 Ports Table 36 X104 X107 X110 USB 2 0 Ports Pin Signal Name 4 pin USB Connector Typ A Version 2 0 1 VCC 2 Data 3 Data 4 GND 13 1 5 X112 X113 X203 DisplayPorts Table 37 X112 X113...

Страница 118: ...4 DTR Data Terminal Ready 5 GND Signal Ground 6 DSR Data Set Ready 7 RTS Request to Send 8 CTS Clear to Send 9 RI Ring Indicator Table 39 X114 Serial Interface COM 1 configured as single RS485 Pin Sig...

Страница 119: ...ector male 1 TxD COM1 Transmit Data 2 TxD COM1 Transmit Data 3 RxD COM1 Receive Data 4 RxD COM1 Receive Data 5 GND Signal Ground 6 TxD COM2 Transmit Data 7 TxD COM2Transmit Data 8 RxD COM2 Receive Dat...

Страница 120: ...es WideLink and DP 3 can be ordered as optional extension of your KBox C 103 system Table 43 X201 WideLink 13 2 3 X 203 3rd DisplayPort For pin assignment refer to 13 1 5 This port must be factory ins...

Страница 121: ...Port RS232 RS422 configured as RS232 Table 44 Serial Port RS232 RS422 configured as RS232 Pin Signal Name 9 pin D SUB Connector male 1 DCD Data Carrier Detect 2 RXD Receive Data 3 TXD Transmit Data 4...

Страница 122: ...and 2 respectively pin 7 and 8 in order to enable the onboard termination resistor 120 Table 46 X204 CAN Bus Port Pin Signal Name 9 pin D SUB Connector male 1 TERM L 2 CAN_L CAN_L bus line dominant l...

Страница 123: ...amily IOL IPMI Over LAN IOT Internet of Things IPMI Intelligent Platform Management Interface KCS Keyboard Controller Style KVM Keyboard Video Mouse MEI Management Engine Interface NCSI Network Commun...

Страница 124: ...KBox C 103 CFL x User Guide Rev 1 0 www kontron com 124...

Страница 125: ...tions With its standard products and tailor made solutions based on highly reliable state of the art embedded technologies Kontron provides secure and innovative applications for a variety of industri...

Отзывы: