KBox B-201-CFL - User Guide, Rev 1.3
// 41
8.3.1.
Mounting brackets Mount Options
Figure 25: Mounting Brackets Desktop Mount Options
Mounted (fixed) on a desktop
Mounted (fixed) underneath a desktop
Danger of Fire
If mounted horizontally with top cover facing downward, the KBox B 201-CFL may overheat
and hot substances may exit through the top cover’s ventilation openings causing a fire
hazard. To avoid risk of fire observe the following:
•
DO NOT mount horizontally with the top cover facing downward
•
Only use the allowed mount orientations:
•
Horizontally (with top cover facing upwards)
•
Vertically (all possible mount orientations)
Figure 26: Mounting Brackets Wall Mount Options
KBox B-201-CFL mounted with bottom side facing the mounting surface (four mount options)
Front panel (above)
Front panel (below)
Front panel (right)
Front panel (left)
KBox B-201-CFL mounted with top cover ventilation openings facing the mounting surface (four mount options)
l
Front panel (above)
Front panel (below)
Front panel (right)
Front panel (left)