The KBox B-201-CFL can operate horizontally (upward orientation only) and vertically when mounted on a desk, wall
or rear side of a monitor. The KBox B-201-CFL is supplied with four chassis feet. Optional installation accessories are
a vertical stand, wall mount brackets, and a VESA 100 mount assembly. Before, installing, observe the following:
Danger of Fire
If mounted horizontally with top cover facing downward, the KBox B 201-CFL may overheat
and hot substances may exit through the top cover’s ventilation openings causing a fire
hazard. To avoid risk of fire observe the following:
•
DO NOT mount horizontally with the top cover facing downward
•
Only use the allowed mount orientations:
•
Horizontally (with top cover facing upwards)
•
Vertically (all possible mount orientations)
Do not handle the product if there is any visible damage.
Prior to any installation work ensure that there are no live wires on the installation site and
follow the local/national regulations for grounding. The voltage feeds must not be
overloaded. Adjust the cabling and the overcurrent protection to correspond with the
electrical specification on the type label.
Kontron recommends that the last cable attached
to the product is the power cable.
Obstructing the ventilation openings may cause overheating.
•
Do not to place items directly in front of the top cover ventilation openings
•
Observed that all ventilation openings are not covered or obstructed by objects
Leave sufficient clearance (keep out area) to prevent the product from overheating!
To ensure proper operation use the specified recommended keep out areas of :
•
Top cover: 10 mm (0.394")
•
Left and right sides: 10 mm (0.394")
•
Front and rear panel: 10 mm (0.394")
•
Bottom side: (no restriction)
Install and operate the product only by trained and qualified personnel within an
environment that fulfills all necessary technical and environmental requirements.
Ensure support for the product’s load by mounting on a flat, solid surface and use of the
specified screws.
Support the power and I/O cables to minimize the strain on the product’s connectors.
Ensure there is clearance for users to
•
Connect cables on the rear I/O panel
•
Access the power-on button on the front panel
•
Install PCIE cards on the right side (clearance 110 mm)