S&S Northern Merlin RS Series Скачать руководство пользователя страница 3

Merlin RS Installation & Operation Manual

 

 

REV 06                                                                                                                                                                                     Page 3 of 12

 

IMPORTANT INFORMATION 

 

 

 

Take extra care where this symbol is used to understand the nature of any potential hazards and how to avoid them.

 

 

 

 

Before any installation, use or maintenance, read this manual carefully. 

 

This product is for Dry Environment Use only. 

 

Avoid prolonged use in dusty environments. 

 

The information contained within this manual should be referred to for typical installation and operation only. 

 

For site specific requirements that may deviate from the information in this manual 

 contact your supplier. 

 

If the equipment is used in a manner not specified by the manufacturer, the safety and protection provided by 
the equipment may be impaired. 

 

Installation must be in accordance with recognised standards in the country concerned. 

 

The PCB contains circuitry that can be damaged by static discharge. 

 

When metal conduit is used provision shall be provided by the installer for bonding in accordance with the NFPA70. 

 

Cables must be protected against mechanical damage. 

 

This product is not designed to detect smoke, fire or other gases and should NOT be used as such. 

 

This device requires a continual supply of electrical power 

 it will not work without power. 

 

A switch or circuit breaker must be fitted, it must be accessible and marked as the disconnecting device. 

 

This product should not be used to substitute appropriate ventilation and exhaust systems. 

 

This product may not safeguard individuals with specific medical conditions. If in doubt, consult a doctor / 
physician. 

 

Your product should reach you in perfect condition, if you suspect it is damaged, contact your supplier. 

 

Manufacturer’s Warranty 

 

The manufacturer warrants to the original consumer purchaser, that this product will be free of defects in material and workmanship 
for a period of 3 Years from the date of purchase. 

The manufacturer’s liability hereunder is limited to replacement of the product with repaired product at the discretion of th

manufacturer. This warranty is void if the product has been damaged by accident, unreasonable use, neglect, tampering or other 
causes not arising from defects in material or workmanship. This warranty extends to the original consumer purchaser of the product 
only. Any implied warranties arising out of this sale, including but not limited to the implied warranties of description, merchantability 
and intended operational purpose, are limited in duration to the above warranty period. In no event shall the manufacturer be liable for 
loss of use of this product or for any indirect, special, incidental, or consequential damages, or costs, or expenses incurred by the 
consumer or any other user of this product, whether due to a breach of contract, negligence, strict liability in tort or otherwise. The 
manufacturer shall have no liability for any personal injury, property damage or any special, incidental, contingent, or consequential 
damage of any kind resulting from gas leakage, fire, or explosion. This warranty does not affect your statutory rights. During the 
above warranty period, your product will be replaced with a comparable product if the defective product is returned together with 
proof of purchase date. The replacement product will be in warranty for the remainder of the original warranty period or for six 
months 

 whichever is the greatest. 

Disposing of Electrical & Electronic Equipment (WEEE) 

When this product has reached the end of its life it must be treated as Waste Electrical & Electronics Equipment (WEEE). Any WEEE 
marked products must not be mixed with general household waste, but kept separate for the treatment, recovery and recycling of the 
materials used. Please contact your supplier or local authority for details of recycling schemes in your area. 

 

Содержание Merlin RS Series

Страница 1: ...com Merlin RS Series Safety Health Monitoring Room Sensors INSTALLATION OPERATION Please read these instructions carefully before use and retain for future reference These instructions can also be dow...

Страница 2: ...Information 4 Coverage 4 Positioning 4 Mounting Instructions 5 PCB Overview 5 Power Wiring 6 10V Output Wiring 6 VFC Relay Wiring 7 Thermistor Wiring 7 RS 485 Wiring 7 Analog Configuration Switches 8...

Страница 3: ...in material and workmanship for a period of 3 Years from the date of purchase The manufacturer s liability hereunder is limited to replacement of the product with repaired product at the discretion of...

Страница 4: ...knowledge of CO2 dispersion process plant systems and any equipment involved Seek advice where necessary in consultation with both safety and electrical engineering personnel Consider air flow pattern...

Страница 5: ...mm 1 2 cut out Execute the mounting and connections NOTE Terminals are pluggable type for ease 4 Secure the front cover by aligning the top and then securing the M2 screw in place PCB Overview All Cla...

Страница 6: ...inear output for CO2 PPM Temperature C F and Humidity rH During normal operation the output of the device is proportional to the values In normal operation output levels are proportional to the gas le...

Страница 7: ...configured in a single bus topology connecting multiple buses in parallel or branching multiple units from the main bus may introduce impedance mismatches reflections and or signal distortions Ensure...

Страница 8: ...Output Linear Scale ON 2 10V OFF 0 10V OFF 0 10V B1 NOT USED B2 NOT USED The average concentration of CO2 in air is around 400ppm or 0 4 TH Temperature and Humidity Digital RS 485 Configuration Switch...

Страница 9: ...e a valid reading output There are no warnings alarms for Temperature or Humidity levels CO2 warning levels will depend on configuration at install PPM Parts Per Million CO2 Range OK Low CO2 Warning H...

Страница 10: ...utputs 1x SPST 70mA Thermistor Betatherm 10K3A1B For alternative Thermistors contact your supplier Cable Spec Power 1 0 2 5mm2 max Analog Output 1 0 2 5mm2 max Digital Output 1 0 2 5 mm2 twisted pair...

Страница 11: ...Merlin RS Installation Operation Manual REV 06 Page 11 of 12 Page intentionally left blank...

Страница 12: ...ort is made to ensure the accuracy of this document however S S Northern can assume no responsibility for any errors or omissions in this document or their consequences S S Northern would greatly appr...

Отзывы: