VENTILATION FAN

WARNING

READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with the homeowner.

Model:   PCD110XMH

CAUTION

CLEANING & MAINTENANCE

OPERATION

For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit 

with the dusting brush attachment.

The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, 

replace the motor with the exact service motor. The impeller should also be replaced.

The control box, located inside the fan housing, has three separate 

adjustments: 

(1) The low airflow knob adjusts the lower airflow from 40CFM up to 

the air flow rate of the high fan speed determined by the toggle switch 

setting.  

(2) The Humidity Sensor Knob set user adjustable setpoint (50%-100% 

relative humidity).

(3) The toggle switch will adjust the upper fan speed setting from 

 90 to 140 CFM .  

WARNING -TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE 

FOLLOWING:

a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

b). Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent 

power from being switching on accidentally. When the service disconnecting means cannot be locked, securely fasten a 

prominent warning device, such as a tag, to the service panel. 

c). Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and 

standards, including fire-rated construction codes and standards. 

d). Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning 

equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as 

those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration 

and Air Conditioning   Engineers (ASHRAE), and the local code authorities. 

e). When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 

f). Ducted fans must always be vented to the outdoors. 

g). Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch 

circuit (ceiling installation only). 

h). This unit must be grounded. 

i). Not for Use in Kitchens.

j). Install Fan At Least 2.5 m (8.2 feet) Above The Floor.

k). To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces 

within walls or ceilings or into attics, crawl spaces, or garages

l).  WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control 

Device.

m). The fan must not be installed in a ceiling thermally insulated to a value greater R40

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 

2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. 

DO NOT MOUNT THIS PRODUCT IN A WALL. 

3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off 

power unit. 

4. Please read specification label on product for further information and requirements. 

   *The manual in electronic format can be download in our company web, or obtained from our dealer.

-

+

-

+

1 2 3

1 2 3

Toggle switch

Power box

Low airflow 

knob

is the position of switch

Humidity sensor 

knob

Cod

0060301242

90

110

120

140

1 2 3

1 2 3

1 2 3

6"

Switch 

position

Duct 

diameter

(inches)

Airflow

(CFM)

6"

6"

6"

90

110

120

140

1 2 3

1 2 3

1 2 3

1 2 3

6"

Switch 

position

Duct 

diameter

(inches)

Airflow

(CFM)

6"

6"

6"

Factory setting: 110CFM (                    ) 

HVI Certified performance based on HVI Procedures 915,

916, and 920.

with 6" duct

Содержание PCD110XMH

Страница 1: ...ine and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities e When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities f Ducted fans must always be vented to the outdoors g Acceptable for use ov...

Страница 2: ... around Housing FAN HOUSING ROUND ELBOW S Seal duct joints with tape Keep duct runs short HUMIDITY SENSOR OPERATION The humidity sensing fan use a sophisticated humidity sensor that responds to a rapid to moderate user adjustable increases in humidity or b humidity above a user adjustable set point 50 100 relative humidity Fan run continuously at a preset lower level set by Humidity sensor knob an...

Страница 3: ...not included Using tape not included secure all the ductwork connections so that they are air tight Run 120 V AC house wiring to the location of the fan Use only UL approved connectors not included to attach the house wiring to the wiring plate Refer to the wiring diagram and connect the wires as shown ASSEMBLY INSTRUCTIONS CONNECT ELECTRICAL WIRING HANGER BAR NAIL SCREW 3 FAN FAN SWITCH BOX WHT F...

Страница 4: ...t improper maintenance or repair faulty installation or installation contrary to recommended installation instructions S P s obligation to repair or replace at S P s option shall be the purchaser s sole and exclusive remedy under this warranty No labor or materials are covered by this warranty S P shall not be liable for incidental damages arising out of or in connection with product use or perfor...

Отзывы: