VENTILATION FAN

WARNING

Models: PC50XP

READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with the homeowner.

CAUTION

CLEANING & MAINTENANCE

OPERATION

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the 

address or telephone number listed in the warranty.

2. Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to 

prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely 

fasten a prominent warning device, such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes 

and standards, including fire-rated construction codes and standards.

4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning  

equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such 

as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refriger-

ation and Air Conditioning  Engineers (ASHRAE), and the local code authorities.

5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

6. Ducted fans must always be vented to the outdoors.

7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch 

circuit (ceiling installation only).

8. This unit must be grounded.

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. 

3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off 

power unit.

4. Please read specification label on product for further information and requirements. 

For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit 

with the dusting brush attachment.

The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual 

noises, replace the motor with the exact service motor. The impeller should also be replaced.

See “CONNECT ELECTRICAL WIRING” for details.

Cod: 0060302628-A

Содержание PC50XP

Страница 1: ...National Fire Protection Association NFPA and the American Society for Heating Refriger ation and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 Acceptable for use over a tub or shower when connected to a GFCI Ground Faul...

Страница 2: ...r onto the other side of the joist through the hole d Screw hanger bar to the housing with screw e Secure the hanger bar onto the housing with screw 3 Mount to I joist a Slide one hanger bar into the channel on the housing and adjust as needed b Hold the housing in place so that the lower mounting flange contacts the bottom of the joist c Screw housing to the joist through the holes on the lower m...

Страница 3: ...ed air flow 4 Install DUCT AND BLOWER ASSEMBLY Hole Hole Hole a Install duct from the inside of the housing Fix the duct by the tab b Fix the BLOWER ASSEMBLY to the housing by 3 screws RETROFIT INSTALLATION 1 Remove wire panel and blower assembly before installation 2 Fold mounting ears flat against housing Blower assembly Wire panel 3 Enlarge ceiling opening to 9 1 2 by 9 1 2 leave ductwork and wi...

Страница 4: ...AR PURPOSE During this five year period S P will at its option repair returned products or parts or provide replacement products or parts without charge for any product or part which is found to be defective under normal use This warranty does not cover normal maintenance and service or any parts that have been subject to misuse negligence accident improper maintenance or repair faulty installatio...