S&P CETHEO Скачать руководство пользователя страница 1

CETHEO

Installation manual and comissioning

EN

Содержание CETHEO

Страница 1: ...CETHEO Installation manual and comissioning EN...

Страница 2: ......

Страница 3: ...It is preferable to transport or handle the CETHEO in a vertical position It may however be laid horizontally 90 max from time to time during handling while respecting the sense as indicated below A p...

Страница 4: ...a long period it is essential to drain the tank Contents 3 1 General information 4 2 Technical information 5 3 Installation 8 4 Hydraulic connections 9 5 Connection to the VMC 11 6 Characteristics and...

Страница 5: ...g safety use and installation The use of parts not supplied by Soler Palau 1 3 Safety Normes g n rales de s curit The CETHEO has an electrical thermodynamic system using high pressure refrigerant gas...

Страница 6: ...tions 2 2 Description of the CETHEO Condenser Compressor Control Evaporator Fan Filter 2 3 Special feature of the CETHEO The CETHEO is equipped with a bypass system providing two functioning modes Ven...

Страница 7: ...air duct from the house To avoid heat loss and to best optimise the performance of your system ducts should be insulated and pass through the heated area Evacuation This spigot is to connect the exhau...

Страница 8: ...Weight 180 Kg 2 3 b Remote control 2 3 Dimensional characteristics 2 3 a CETHEO 7...

Страница 9: ...ith a ceiling height greater than 2 2 m be placed so that access to the front panel is unobstructed to allow work on the active parts of the CETHEO be placed as close as possible to the take off point...

Страница 10: ...safety unit and the tank Place an isolation valve upstream of the safety unit It is forbidden to fit a flexible between the safety unit and the tank Provide an outlet connection F32 for waste water c...

Страница 11: ...d water take off H 100 mm Fig 7 Hydraulic connection CETHEO 10 Temperature probe Immersion heater access door The CETHEO must be placed in the heated area of the individual residence meeting the NFC 1...

Страница 12: ...HEO and in the exterior part in the discharge part between the CETHEO and the chimney cap or the fa ade grille For the extraction circuit it is preferable to use 50 mm or 25 mm insulated ducting place...

Страница 13: ...5VV F 3G1 5 Length supplied 1 2 m Do not start up the CETHEO until the finalised air circuit recirculation grille or roof outlet extraction vents circuit and filter fitted and the tank is full 12 Rese...

Страница 14: ...art up current A 6 4 Maximum compressor power consumption W 400 Power electrical resistance W 1 500 Maximum fan power consumption W 40 Maximum power consumption W 1900 Compressor protection fuse aM A...

Страница 15: ...with keys 5 or 6 Validate with key 7 Press key 6 and the month is displayed To modify it press the validation key 7 The month blinks Set the required month with keys 5 or 6 Validate with key 7 Appuyer...

Страница 16: ...robes to be read Validate with key 7 and the message Password is displayed followed by the value 0 blinking To enter the password press key 6 until the code is reached then validate with key 7 After p...

Страница 17: ...n to black and indicates the number of days remaining before the HP is stopped 14 day countdown If the filter is not changed before the allotted time and the HP stops the error message E04 is displaye...

Страница 18: ...riod By pressing key 6 the number of days before automatic restarting can be chosen Validate with key 7 On restarting manual or automatic the CETHEO goes into BOOST mode automatically 3 Boost mode To...

Страница 19: ...densate exhaust properly connected siphon Check that all the connections are really airtight on the Cetheo on plenums and on plugs Check the calibration of the electrical protector 10A 2 Fill the tank...

Страница 20: ...f Automatic Filter blocked E05 D faut ventilateur PAC off Automatic R seau inadapt Ventilateur d fectueux E06 Alarme position By pass PAC off Automatic Contact d fectueux Moteur By pass d fectueux Ele...

Страница 21: ...ic supply to the CETHEO Open the hot water tap Open the safety group drain tap 20 Before starting any work switch your appliance off 1 2 1 Maintenance by a professional The CETHEO does not require any...

Страница 22: ......

Страница 23: ......

Страница 24: ...S P SISTEMAS DE VENTILACI N S L U C Llevant 4 08150 Parets del Vall s Barcelona Tel 34 93 571 93 00 Fax 34 93 571 93 01 www solerpalau com...