– 97 –
3. MEMORY SWITCH DATA LIST
Memory switch data are the motion data that the sewing machine has in common and the data
that operate on all sewing patterns in common.
3-1. Data list
No.
Item
Setting range
Edit unit
Maximum sewing speed
200 to 2800
100 sti/min
Sewing speed of 1st stitch
In case of with thread clamp
200 to 900
100 sti/min
Sewing speed of 2nd stitch
In case of with thread clamp
200 to 2800
100 sti/min
Sewing speed of 3rd stitch
In case of with thread clamp
200 to 2800
100 sti/min
Sewing speed of 4th stitch
In case of with thread clamp
200 to 2800
100 sti/min
Sewing speed of 5th stitch
In case of with thread clamp
200 to 2800
100 sti/min
Thread tension of 1st stitch
In case of with thread clamp
0 to 200
1
Thread tension setting at the time
of thread trimming
0 to 200
1
Thread tension changeover
timing at the time of thread trimming
– 6 to 4
1
Sewing speed of 1st stitch
In case of without thread clamp
200 to 1500
100 sti/min
Sewing speed of 2nd stitch
In case of without thread clamp
200 to 2800
100 sti/min
Sewing speed of 3rd stitch
In case of without thread clamp
200 to 2800
100 sti/min
Sewing speed of 4th stitch
In case of without thread clamp
200 to 2800
100 sti/min
Sewing speed of 5th stitch
In case of without thread clamp
200 to 2800
100 sti/min
Thread tension of 1st stitch
In case of without thread clamp
0 to 200
1
Thread tension changeover timing
at the time of sewing start
In case of without thread clamp
– 5 to 2
1