Port Profile
The following table describes the labels in this screen.
Label
Description
Serial to Ethernet
Flush Data Buffer After:
The received data will be queued in the buffer until all the delimiters
are matched. When the buffer is full (4K Bytes) or after "
flush S2E
data buffer
" timeout, the data will also be sent. You can set the time
from 0 to 65535 seconds.
Delimiter:
You can define max. 4 delimiters (00~FF, Hex) for each way. The
data will be hold until the
delimiters are received or the option “
Flush
Serial to Ethernet data buffer
” times out. 0 means disable. Factory
default is 0
Ethernet to serial
Flush Data Buffer After:
The received data will be queued in the buffer until all the delimiters
are matched. When the buffer is full (4K Bytes) or after "
flush E2S
data buffer
" timeout, the data will also be sent. You can set the time
from 0 to 65535 seconds.
Delimiter:
You can define max. 4 delimiters (00~FF, Hex) for each way. The data
will be hold until the delimiters are received or the option “
Flush
Ethernet to Serial data buffer
” times out. 0 means disable. Factory
default is 0
Service Mode
– Virtual COM Mode