You must assign a valid IP address for SC10E4I before attached in your network environment.
Your network administrator should provide you with the IP address and related settings. The IP
address must be unique and within the network (otherwise, SC10E4I will not have a valid
connection to the network). You can choose from three possible “
IP configuration
” modes: Static,
DHCP/BOOTP. The Factory Default IP address is “
192.168.10.2
”
The following table describes the labels in this screen.
Label
Description
DHCP/BOOTP
Obtain the IP address automatically from DHCP server.
Static IP Address
Assigning an IP address manually.
Subnet Mask
Set the subnet mask to communicate on the network.
Gateway
Enter the IP address of the router in you network.
DNS Server
Enter the IP address of the DNS server to translate domain names
into IP address.
Switch Mode
Redundant:
When the connection between master-link and LAN fails, the
SC10E4I can automatically switch to another LAN port within10mS,
and still guarantees a non-stop connection
Switch:
Daisy Chain support to reduce usage of switch ports.
Authentication
You can set the password to prevent unauthorized access from network. Input the “
Old password
”
and “
New password
” to change the password. Factory default is no password.