53
Figure 64
Click on the COMX port under
Serial
on the left hand side.
Select UDP in the Link modes.
Destination IP and Port:
Specify the
Begin
and
End IP
here. Four groups of range IPs are
allowed. This is the
IP
address of the UDP program and the
Port
it is listening to. Note that the
maximum number of UDP nodes that SC10E16A1 Series can handle would highly depend on
the traffic load.
We have tested that SC10E16A1 Series can handle up to 100 UDP nodes (baud
rate 9600 bps, request interval 100ms, and data length 30bytes).
Enter the
Local Listening Port
. This is the port that SC10E16A1 Series should listen to. Match
this setting in the UDP program (usually called destination port in the UDP program).
For serial settings, go to
Sec.3.4.1
. For Advanced settings, go to
Sec.3.4.2
Scroll to the bottom of the page and click on “
Save Configuration
” button to save the changes.
4.2 Link Mode Applications
4.2.1 TCP Server Application: Enable Virtual COM
SC10E16A1 Series will encapsulate control packets on top of the real data when Virtual COM is
enabled. This will allow the Virtual COM port in the Windows/Linux system to access SC10E16A1