For setting as a TCP Client, please follow these steps.
Click on the COMX port under
Serial
on the left hand side.
Select TCP Client in the Link modes.
Only two communication modes are available here: RAW and Virtual COM which definitions are
Enter the preferred
Destination IP
and
Port
. This should match the IP settings of the TCP
Server program.
Enable and enter Destination IP 2 and Port 2 if necessary. Two different servers can be set here
(for redundancy), the second server has to be enabled by ticking the box.
Go to
for more information on this setting. For serial settings, go to
Sec.3.4.1
. For Advanced settings, go to
Sec.3.4.2
Scroll to the bottom and click on “
Save Configuration
” button to save the changes.
4.1.3 UDP Mode
UDP is a faster but connectionless network protocol; it does not guarantee the delivery of network
datagram. The SC10E16A1 Series can be configured to transfer data using unicast or multicast UDP
from the serial device to one or multiple host computers, data can be transmitted between serial
device and host computer in both directions.
There is no
server
or
client
concept on this protocol, they are called
peers
or
nodes.
So here you