background image

San Telequip (P) Ltd., 
4 Crystal House, 235, Navi Peth 
Off LBS Road, Pune 411 030, India 
Phone : 91-20- 24320023, 24334423, 65001587                                               Connecting. Converting. Leading ! 
email : [email protected]                                                                                                                                   

 

Document Name : User Manual for 4 RS485 Hub, Model SC08 S4 

 

SC08S is a RS485 hub specially designed to meet the requirements of RS485 under difficult field environments. 
A transmission rate as high as 115.2 Kbps is supported, RS485 is 2.5KV Opto isolated, 1500W surge protected 
to avoid lighting or surges, ensuring safety and reliability of the device. All the terminals are Short circuit 
protected.  

 

The transmission distance is as far as 1200 meters. This product is widely used in Express way toll system, 
Energy monitoring system etc. 

 

Specifications 

Interface  

 

: Compatible with RS232C and RS485 standards of EIA/TIA 

Serial Input  

 

: RJ45 ports for RS232 & RS485 

Working mode  

 

: Asynchronous half-duplex 

Indicators 

 

: 7 signal indicator including P, TD, RD and failure (E1-E4) 

Isolation  

 

: 2500 VRMS 

Baud rate  

 

: 300bps -115.2Kbps 

Protection RS-232  

: 15KV ESD 

Protection RS-485  

: 1500W lighting strike surge protection for each line 

Protection 

 

: Short Circuit 

Port Isolation 

 

: Each port is isolated with all other ports 

Transmission distance  

: 1200m 

Dimension 

 

: 90mm X 69mm X 23mm 

Power Supply 

 

: 230V AC External adapter. 5V DC, 1A output 

Working environment  

: Temp 0 to 50

°

C, Relative humidity 5% to 95% 

 

Panel and Indicators 

There are 7 indicator lights on the front panel of SC08S, and on the back panel there are RJ45 connectors for 
RS485 or RS232 ports 

 

 

 
 
 
 
Front Panel                                                                                                                                          

Back Panel 

 
PWR 

Power, Green for Power ON 

TXD 

Data send from Input to 4 Output ports, Green for normal transmission 

RXD 

Data receive from 4 Output to 1 Input port, yellow for normal reception 

E1-E4  Failure alarms, ON to indicate short circuit or wrong signal connection of ports 1-4 

 

Pin Definitions 

 

RS232 Interface 

 

RS485 Interface 

RJ 45  
Connector 

Definition  Direction  RJ 45  

Connector 

RS485 

TX 

OUT 

1, 2 

TX+/D+ 

RX 

IN 

3, 4 

TX- / D- 

GnD 

 

7, 8 of Port 4 

Ground 

 

Cable Connection Diagram 

RJ45  Pin 

TO 

DB9 Male 

RS232 

TX 

 

RX 

RX 

 

TX 

GND 

 

GND 

 

Note : Pin 7 & 8 of Port 4 is Protection Ground for Surge circuit. Ground these pins properly 

 