SAMWON
SAMWON
SAMWON
SAMWON ENG
ENG
ENG
ENG
SU
SU
SU
SU-
-
-
-503
503
503
503B
B
B
B Control
Control
Control
Controller User Manual
ler User Manual
ler User Manual
ler User Manual
Page
Page
Page
Page
1/2
4. Sensor Connection Method
4. Sensor Connection Method
4. Sensor Connection Method
4. Sensor Connection Method
Humidity
Humidity
Humidity
Humidity
sensor
sensor
sensor
sensor
①
①
①
①Black
Black
Black
Black ②
②
②
②White
White
White
White ③
③
③
③Shield
Shield
Shield
Shield
Model
Temperature & Humidity Range
Output
SU-503B
Humidity(0~100%)
Main Relay(OUT1)
※
Thank you for purchasing Samwon ENG product. The User Manual is
provided for preventing the damage and trouble of product caused by
carelessness and to inform the precise usage. Please keep it in the safe place
and refer to it when you have any doubt during using this product.
Display
Current humidity / Setting humidity
Main Output Display
Main Output ON/OFF Display
Setting Button
Increase Button
Decrease Button
Hum, Installer Setting Button
Setting Value increase button
Setting Value decrease button
▶ Only for humidity
ON/OFF control.
Variation(dIF) 0.1~25.0%,0~300sec delay timer, forward/converse
Selection function
▶ Lock function for installer / Limit function of Set Value
˚ Limit the range of set humidity
by users⇒ Set limit function
˚ Hysteresis, delay time, forward/converse selection⇒Lock function
▶ Supply power to the controller
Display the current humidity.
▶ Press Set button once. Main output set
Hum value in the right picture flashing
▶To change them, press UP & Down Key.
If you press UP/DN longer than 1 sec
Increased or decrease quickly
※
※
※
※If set Hum limit function
If set Hum limit function
If set Hum limit function
If set Hum limit function
IIIIs working, the setting will be made
s working, the setting will be made
s working, the setting will be made
s working, the setting will be made
within the range
within the range
within the range
within the range....
▶ If you press Set once again,
the set hum will be saved..
Even if switched-off, the set value
will not be deleted..
▶The current hum displayed and
Controller starts to control.
▶Main Output use terminal 4~5.
※
※
※
※
Terminal 6 is used for OFF terminal
Terminal 6 is used for OFF terminal
Terminal 6 is used for OFF terminal
Terminal 6 is used for OFF terminal
S
SS
Should not be used for Main Output.
hould not be used for Main Output.
hould not be used for Main Output.
hould not be used for Main Output.
※
※
※
※A
A
A
Auxiliary output
uxiliary output
uxiliary output
uxiliary output((((alarm
alarm
alarm
alarm////timer
timer
timer
timer)))) use terminal 7, 8.
use terminal 7, 8.
use terminal 7, 8.
use terminal 7, 8. R
R
R
Refer to
efer to
efer to
efer to 9
99
9 alarm output setting
alarm output setting
alarm output setting
alarm output setting
and
and
and
and 10
10
10
10 cycle timer setting
cycle timer setting
cycle timer setting
cycle timer setting....
①
sensor connection method
▶ Please connect as the right picture
If you connect with the changed
wired or use different type sensor
‘
Err
’
to be displayed.
②
senor wire extension method
▶ it is possible within 100m.
You should use the shield inside
cable, in order to prevent
input noise
▶The humidity sensor is electromagnetic
induction method. It should be
Installed in dry place because
The instruction value may be
changed because of moisture or a
drop of water inside the sensor.
▶The life time of the humidity
sensor is 2 years.
③
Sensor Input compensation (the current hum is different)
▶ If sensor cable is too long or sensor is old, there will be hum variation.
At that time, use current hum compensation function (rSt).
▶ At the current hum displayed, press set for 3 seconds.
If dIF displayed, release set. In order to move to rSt (hum
compensation), press set several times.
▶ Input the compensation hum by using up&dn.
If you press set for 3 seconds, it will be saved and the current hum
will be compensated.
For example,
Current Humidity
rSt
humidity
Displayed Hum
20 %
-5 %
15 %
20 %
+
++
+
+
++
+
10 %
=
==
=
=
==
=
30 %
① It is possible that users cannot change the default setting, by using lock
function.
Item
Setting
Description
OFF
Locking off. All function setting possible.
LoC
ON
Only locking and setting hum function
possible.
Item
setting
Description
StH
50
Settable high hum value 50
Default
setting
StL
40
Settable low hum value 40
Terminal
Terminal
Terminal
Terminal
sensor
sensor
sensor
sensor
①
①
①
①
②
②
②
②
③
③
③
③
Hum. sensor
Hum. sensor
Hum. sensor
Hum. sensor
SU
SU
SU
SU-
--
-503B
503B
503B
503B
black
black
black
black
white
white
white
white
red
red
red
red
uncun
1. Function & Name of Parts
1. Function & Name of Parts
1. Function & Name of Parts
1. Function & Name of Parts
Increase
Decreas
Set Button
Main Output
Display
up
up
up
up
dn
dn
dn
dn
set
set
set
set
set
set
set
set
up
up
up
up
dn
dn
dn
dn
3.
3.
3.
3. Main Output Set Value Change
Main Output Set Value Change
Main Output Set Value Change
Main Output Set Value Change
2. Functions
2. Functions
2. Functions
2. Functions
5. External & Panel Dimension
5. External & Panel Dimension
5. External & Panel Dimension
5. External & Panel Dimension
73.2
35
77
(unit: mm)
28+
0.6
PANEL CUT OUT
70
+0.6
6. Set Value Limit
6. Set Value Limit
6. Set Value Limit
6. Set Value Limit & Lock function
& Lock function
& Lock function
& Lock function
<<<< Terminals on Back >
Terminals on Back >
Terminals on Back >
Terminals on Back >
sensor
sensor
sensor
sensor
O
O
O
OUT1
UT1
UT1
UT1
((((Main
Main
Main
Main))))
Power
AC
AC
AC
AC
100~
100~
100~
100~
220V
220V
220V
220V
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪
⑫
<Current Hum>
<Current Hum>
<Current Hum>
<Current Hum>
Coil terminal
Coil terminal
Coil terminal
Coil terminal
메인
메인
메인
메인
전원
전원
전원
전원
작동
작동
작동
작동
기계
기계
기계
기계
AC
220V
Main
Main
Main
Main
Pow
Pow
Pow
Pow
Devi
Devi
Devi
Devi
ce
ce
ce
ce
<<<< Terminals on Back >
Terminals on Back >
Terminals on Back >
Terminals on Back >
sensor
sensor
sensor
sensor
O
O
O
OUT1
UT1
UT1
UT1
((((Main
Main
Main
Main))))
Power
AC
AC
AC
AC
100~
100~
100~
100~
220V
220V
220V
220V
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪
⑫
VAL
Automation
Tel:
00374-10-566720
Fax:
00374-10-543448
E-mail:
Address:
No17, Demirchian St., Yerevan 0002, Armenia
URL:
www.val-automation.am