Connecting a Ground Cable to the Outdoor AP (2)
Connecting a Ground Cable to the Arrestor
1) Prepare the following components:
Table 19.
Components and Tools for Connecting the Ground Cable to the Arrestor
Item
Description
Installation Section
Arrestor Ground Terminal-MGB
Cable
AWG10, F-GV 4 mm
2
× 1C
Heat Shrink Tube
(Spec/Color/Length)
Φ 10 mm/Green/50 mm
Pressure Terminal
MGB
Check the MGB standards for the field and have the
pressure terminal ready.
Arrestor
4 mm
2
, 1 hole, ring-type, hole diameter: 4.2 mm
Fastening Components MGB
Check the MGB standards for the field and have the
fasteners ready.
Arrestor
M4 Screw/1 EA (Installed on the arrestor)
Regulated Torque
Value
M4 Screw
9.52-14.28 kgf·cm
Required Tools
Cable Cutter, Wire Stripper, Crimper, Heating Gun, Torque Driver (+),
Torque Wrench, and Nipper
M6 × 12L SEMS
Pressure Terminal
Outdoor AP Ground Cable
Heat Shrink Tube (Green)