WEA302i/303i/303e Installation Manual
Status LED
Ethernet port
DC input
Console port Reset switch
Introduction
What is WEA302i/303i/303e?
The WEA302i/303i/303e is AP for Samsung WE wireless LAN.
It connects the UE that supports wireless LAN such as a smart phone, tablet PC, or notebook to a
wired network. The WEA302i/303i/303e supports the following features:
- IEEE 802.11a/b/g/n standard
- Power over Ethernet (PoE) IEEE 802.3af
- WEA302i: 2 × 2 MIMO (Multiple Input Multiple Output)
- WEA303i/303e: 3 × 3 MIMO (Multiple Input Multiple Output)
- Wireless LAN through both 2.4 GHz and 5 GHz ISM bandwidth
Component
After unpacking the WEA302i/303i/303e, check whether all of the following items are included.
WEA302i/303i
WEA303e
Common merchandise
Ceiling bracket
Two ceiling clips
Three M3 × L6 screws
(including 1 spare)
Installation Manual
Wall mount bracket installation set (sold separately)
Wall mount bracket
Security torx
(T10) screw
Four plastic
anchors
M4 × L28
Four screws
RJ45 gender
- It is recommended to keep all the packing materials and box.
- The wall mount bracket installation set, power adaptor, and external antenna for WEA303e are sold
separately.
- The cable hole guide seat is provided separately.
This manual describes the configuration of Wireless Enterprise WEA302i/303i/303e and how to
install WEA302i/303i/303e.
The instruction on how to install is described based the WEA302i/303i model, and the instruction
on how to install the WEA303e model is same except for the installation of an external antenna.
Name and Function
Dust covers are installed on a power port (DC 12 V/2.0 A) and console port (CONSOLE).
Remove the cover before use.
Interface
Interface
Description
Status LED
Displays the status information of WEA302i/303i/303e with LED.
DC input
Used when a power adaptor is used for power supply.
Ethernet port
Supports 1000 BASE-T Gigabit Ethernet and PoE IEEE 802.3af standard.
Console port
Checks the operation status of WEA302i/303i/303e and used for CLI input.
Reset switch
Used to restart the WEA302i/303i/303e.
Status LED
LED
Status
Description
System start status
White On
Initial LED status
Blue On
Device reset and test in progress
Red On
Booting failure (Device reset failure)
Provisioning status
Repeated Red, Green, and Off
Connecting APC (network link normal status)
Blinking green
Connecting CAPWAP link (APC server normal connection status)
Normal operation
status
Green On
When there is no connected wireless UE
Blue On
When there is a connected wireless UE
Upgrade
Blinking blue
Upgrading software
Fault status
Blinking red
Abnormal network link (checking link status after disconnection
or re-connection)
Blinking orange
IP address conflict
Blinking violet
Dynamic IP Address allocation failure
Blinking bluish green
Fixed IP check failure
Repeated Red, Blue, and Off
Wireless interface fault status
Installation
The WEA302i/303i/303e can be installed on a ceiling or wall. Please check whether all the components
are included before installation.
Before Installation
Safety Requirements
If the below safety warnings are not properly observed, it may cause a risk.
Make sure to be informed for safe use.
- There is an electrical risk with the product. Make sure that the power is turned off during installation.
Do not proceed with the installation when there is current leakage. Otherwise, this may cause serious
personal injury.
- Wear anti-static gloves or take an appropriate action to prevent ESD during product handling.
- Do not connect a phone line connector to an Ethernet port. This may damage the product.
- This product must be connected to a power supply in compliance with IEEE 802.3af or to a limited power
supply in compliance with IEC60950.
- This product must be installed or removed only by appropriately trained service personnel.
- This product is operating in the Safety Extra Low Voltage (SELV) state according to IEC60950.
- All the connected equipment including this product must be installed inside of the same building.
For more information, refer to the Environment A of IEEE 802.3af standard.
Installation Instructions
The below instructions must be observed during installation.
- The system must be easily accessible for product installation, cable connection, or maintenance.
- The PoE LAN cable must be installed always away from an electrical interference source such as
power line, fluorescent light, radio, or transmitter.
- The PoE LAN cable must be CAT 5E or higher.
- If it is not easy to use PoE, a power adapter (sold separately) can be used.
The 3-pin (including ground) power consent that supplies 100-240 V AC, 50-60 Hz must be located
within 2 m from equipment and the power must be supplied through an independent circuit breaker.
It is recommended to use equipment that uses a filter or surge breaker.
- The ambient temperature must be maintained between 0'C and 45°C. The ambient humidity,
in absence of air pressure change, must be maintained between 10 % and 90 %.
Installation on a Ceiling
If the WEA302i/303i/303e is incorrectly installed on the ceiling, the product may drop onto a person or
equipment. Therefore, make sure to fix it firmly.
1.
Place a ceiling bracket by making its convex part
upward and align a ceiling clip to the groove of the
ceiling bracket and insert the clip to the position that
is shown in the figure.
Push and move the ceiling clip according to the
T-bar size of the ceiling.
2.
Fix the ceiling clip to the ceiling bracket by tightening
one M3 × L6 screw to either of the two holes.
If the T-bar size of ceiling is 15 mm, 24 mm, or
38 mm, you can check a fixing position where a
ceiling clip can be fixed on the floor of ceiling
bracket.
If the T-bar size is unknown, tighten the two ceiling
clips using one screw each in the step 4.
3.
Align the ceiling clip on the other side to the groove
of ceiling bracket and insert the clip.