E-
5
ENGLISH
Deciding on where to install the indoor unit
Indoor unit
There must be no obstacles near the air inlet and outlet.
Install the indoor unit on a ceiling that can support its weight.
Maintain sufficient clearance around the indoor unit.
Make sure that the water dripping from the drain hose runs away correctly and safely.
The indoor unit must be installed in this way, that they are out of public access. (Not touchable by the users)
After connecting a chamber, insulate the connection part between the indoor unit and the chamber with t10 or
thicker insulation. Otherwise, there can be air leak or dew from the connection part.
Space requirements for indoor unit
0.196inch(5mm)
You must have
1.969inch(5mm)
or more space between the ceiling and the bottom of indoor unit. Otherwise, the noise from the
vibration of indoor unit may bother the user.When the ceiling is under construction, the hole for check-up must be made to take
service, clean and repair the unit.
It is possible to install the unit at an height of between
7.2ft(2.2m) ~ 8.2ft(2.5m)
from the ground, if the unit has a duct with a well
defined lenght (
1ft(304.8mm)
or more), to avoid fan motor blower contact.
4.58ft(1398mm) X 1.3ft(400mm)
or more
(A space for repair and service)
The units must be installed according to distances declared, in order to
permit accessibility from each side, either to guarantee correct operation
of maintenance or repairing products.
The unit’s parts must be reachable and removable completely under
safety condition (for people or things).
CAUTION
Weight
Net weight
Indoor Unit
DH105CAV
kg(Ib)
39(86)
DH140CAV
55(121.1)
Outdoor Unit
UH105CAV
90(198.4)
UH140CAV
94(207.2)
4.9f
t or
mor
e
4.9f
t or
mor
e
4.9f
t or
mor
e
4.9f
t or
mor
e