7. Setting Up the SVMi-20E with the OfficeServ 7200/7400 Systems
This section provides the additional steps required to set up the SVMi-20E card for operation in the OfficeServ
7200/7400 Series telephone system products. Included here is information regarding the software set up for
the phone system.
After inserting the SVMi-20E card and turning the power on there are some key system options that should
be set, in order for the SVMi-20E to function correctly. These steps are performed in the phone system. It is
necessary to perform these at this time so that the SVMi-20E will initialize properly and synchronize its mail-
box database with that of the key system.
7.1 Power Up Procedure
Follow the steps below to ensure that the SVMi-20E is properly setup.
7.1.1 POWER UP
1.
Complete insertion of the SVMi-20E and all other required interface cards and turn the sys-
tem power switch ON.
2.
There are 8 LEDs on the front of SVMi-20E. We will watch three during power up., the PGD,
HDD, and the SDN LEDs:
The PGD LED-will show steady green when the SVMi-20E I srceiving Power fron the
OfficeServ 7200/7400 Series Back Plane connectors. The HDD LED- will show hard drive
access and will flicker whenever the HDD (hard drive) is being accessed. The SDN LED – will
start off Green as the SVMi-20E is booting up (it will also turn Green when the SVMi-20E is
shut down properly). It will turn Orange after the Voice Drivers are loaded into memory
and then turn RED when the application Software is fully loaded. RED is warning letting
you know the aaplication is running and it is NOT safe to power down the OfficeServ
7200/7400 Series System.
7.1.2 SYSTEM PROGRAMMING
Review and perform the following programming steps 1 through 7. It is necessary to perform
these at this time so that the SVMi-20E will read these MMCs and initialize accordingly.
NOTE: Before moving forward if you want to change any of the SVMi-20E default Extension and
Mailbox settings it is best to edit your Extension and Mailbox Templates now before initializing
the SVMi-20E.
1.
MMC 601: All SVMi-20E ports installed must be assigned to the BI-VMS station group, usu-
ally 5039 in the OfficeServ 7200 and 5049 in the OfficeServ 7400.
2.
MMC 601: Select either SEQUENTIAL or DISTRIBUTED ring mode (Sequential is recom-
mended).
3.
MMC 207: Confirm that all SVMi-20E ports are set for VMAA use. This will be done auto-
matically. You are just confirming at this point.
4.
MMC 406: If you are using the SVMi-20E for Auto Attendant use MMC 406 to set the desired
trunk(s) to ring the BI-VMS station group.
5.
MMC 102: If you are using the SVMi-20E for Voice Mail make sure that all desired stations
are forwarded to the BI-VMS station group for the appropriate call forward conditions: No-
Answer, Busy, and/or ALL.