Samsung STC-14 Скачать руководство пользователя страница 8

Security IR Camera

User’s Manual

14

Security IR Camera

User’s Manual

15

Interface

Attach the lens cap before storing this device.
Ensure that the storage area is kept within the allowable temperature range listed in this 

device’s product specifications. Do not place this device in a location where condensation 

may occur. 

A user interface terminal block is attached to the inside of this device.

After making adjustments to the internal terminal block, ensure that the back cover is 

properly attached.

3.  Always carry out an NUC whenever sunlight or high temperature objects are within the 

field of view. 

4.  When the camera is used continuously for a long period of time, pay attention to the 

buildup of dirt on the lens.  A dirty lens may result in phenomena such as shortened 
detection distances. 

5.  Even if the same item is being monitored, changes in environmental conditions such as 

rain and fog will affect detection distance. Ensure the camera is operated while being 
aware of how such changes may influence detection distance.

6.  In order to operate the camera properly, ensure suitable usage conditions during 

monitoring. 

External communications cable

RS485 control terminal

(+) CONNECTION TERMINAL (TRX+)

485+

(-) CONNECTION TERMINAL (TRX-)

485-

Storage

Installing the Camera

Using RS485 communications, function settings menus can be adjusted using the Samsung 
Techwin DVR or System controller.

(1) Controlling menus using a PC
Using an RS485 converter, connect the camera's RS485 control terminal to a serial cable.
Example)  PC serial board (COM1)

…→…

serial cable

…→…

RS485 converter

…→…

camera RS485 control 

terminal

(2) Controlling menus using a DVR system controller

Connect an RS485 cable (TRX+, TRX-) to an RS485 control board connection terminal capable of 

connecting to the DVR system controller.

RS485 Communications Controls

Communications Settings Default Values (camera default values at the time of shipment)

•  Please use Samsung Techwin Protocol or Pelco-D Protocol when controlling the camera 

with a separate controller.

Notes

•  Leakage may occur if the back cover is not properly attached.

Notes

After thermal images appear, the camera will begin to monitor its range of coverage. 

1.  Do not adjust the focus if there is no particular point of focus to monitor. 
2.  For an in-depth explanation of the controls used with the STC-14, refer to the section 

detailing how the camera is operated on page 16.

During monitoring, the STC-14 will capture heat sources and display the resulting images on 

the monitor.

1.  If the subject environment experiences a dramatic change in temperature during 

monitoring, be sure to set NUC MODE to either an INTERVAL of 10 MIN or less, or an AMB 

of 1.0°C or lower .

2.  Please be aware that because this is an infrared camera, reflections not visible to the 

naked eye may still be displayed. Images reflected off glass or mirrors located in front of 
the camera may become visible. 

Interface

Monitoring Guidelines

Содержание STC-14

Страница 1: ...era STC 14 User s Manual Thank you for purchasing a SAMSUNG Security IR Camera Before attempting to connect or operate this product please read these instructions carefully and save this manual for future use ENGLISH ...

Страница 2: ...ital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operatio...

Страница 3: ...amsung Techwin cares for the environment at all product manufacturing stages to preserve the environment and is taking a number of steps to provide customers with more environment friendly products The Eco mark represents Samsung Techwin s will to create environment friendly products and indicates that the product satisfies the EU RoHS Directive Features 5 Warnings Cautions 6 Warnings 7 Cautions 8...

Страница 4: ...nsert foreign objects Failure to obey this warning could result in a product failure or fire There is a risk of death or serious injury if the designated instructions are not adhered to The action is forbidden Disassembly is forbidden There is a risk of personal injury or property damage if the designated instructions are not adhered to Explanation of Warnings Cautions Displays Warnings Cautions T...

Страница 5: ...r Do not install the product in very hot or very cold locations Using the product in an area with very hot 55 C or higher or cold 30 C or lower temperatures could result in product failure or a reduction in image quality Ensure proper ventilation wheninstallingtheproductinparticularlyhotlocations Do not drop the product or subject it to strong impacts or vibrations Failure to obey this caution cou...

Страница 6: ...ear 1 3 4 2 A screw to fix the focus is located on the bottom of the lens 2 A sun shield is provided with this camera to allow for outdoor installation Using the bolts and hexagon wrenches included in this package fasten the camera unit and sun shield firmly in place Do not use excessive force during assembly 2 External Part Names Do not adjust the focus after purchasing this product because it wi...

Страница 7: ...ustration Select Hi Z for intermediate video receivers and 75Ω for end equipment Calibration NUC Monitor Communications Connection Installing the Camera 1 Remove the lens cap 2 Engage the power Use the adapter provided with this product 3 The rated input voltage for this product is AC 24 V 50 60 Hz 1 The START screen will appear after the power has been turned on 2 After completion of initializati...

Страница 8: ...chwin DVR or System controller 1 Controlling menus using a PC Using an RS485 converter connect the camera s RS485 control terminal to a serial cable Example PC serial board COM1 serial cable RS485 converter camera RS485 control terminal 2 Controlling menus using a DVR system controller Connect an RS485 cable TRX TRX to an RS485 control board connection terminal capable of connecting to the DVR sys...

Страница 9: ...hether a device abnormality or warning has occurred Power ON Lighting Device Abnormality Warning Flashing KEY controls Enables operation of the menu controls Used to make adjustments Connector specifications and signals Function Chart POWER LED Power ON Lit Abnormality Warning Flashing Terminal Block A RS485 Terminator SW Terminator ON 1 2 Terminator OFF 2 3 Multi Direction S W same connector as T...

Страница 10: ...ure When you select a function a sub menu will appear UP SET Push RIGHT DOWN LEFT Function Explanation BRIGHTNESS AUTO MANUAL level ranging from 1 10 CONTRAST AUTO MANUAL level ranging from 1 10 RANGE AUTO L H NUC NUC NUC MODE INTERVAL AMB MANUAL INTERVAL 0H 1MIN 24H 0MIN AMB 0 1 C 5 0 C IMAGE ADJ 3D DNR OFF L M H SHARPNESS 0 5 ZOOM OFF X2 X4 POLARITY BW WB SPECIAL TV SYSTEM NTSC PAL LANGUAGE ENGL...

Страница 11: ... the cursor is aligned with 1 BRIGHTNESS to display the BRIGHTNESS sub menu shown below Press the LEFT button or RIGHT button while the cursor is aligned with AUTO to switch the BRIGHTNESS AUTO ADJUST setting from ON OFF ON Press the LEFT button or RIGHT button while the cursor is aligned with MANUAL to adjust the BRIGHTNESS over ten different levels 1 2 3 4 5 6 7 8 9 10 1 Select 2 RETURN to confi...

Страница 12: ...settings Press the LEFT button or RIGHT button while the cursor is aligned with 3 D ZOOM to switch the zoom setting from OFF X2 times two X4 times four OFF Select 5 RETURN to confirm the current setting and go back to the MAIN SETUP menu screen Default value OFF SHARPNESS edge emphasis Use this option to use image processing to emphasize edges Press the LEFT button or RIGHT button while the cursor...

Страница 13: ... RATE to one of four settings 38 400 bps 19 200 bps 9600 bps 4800 bps Press the LEFT button or RIGHT button while the cursor is aligned with 2 BAUD RATE to switch the BAUD RATE setting from 4800 9600 19 200 38 400 4800 Select 6 RETURN to confirm the current setting and go back to the SPECIAL SETUP menu screen Default value 9600 bps UART MODE parity settings mode Use this option to adjust parity se...

Страница 14: ... the SET button while the cursor is aligned with 8 SAVE to record your current settings to the internal memory If you exit without saving the MAIN SETUP menu will close without any values being updated Press the LEFT button or RIGHT button while the cursor is aligned with 5 DISPLAY ID to switch the CAMERA ID display setting from ON OFF ON Select 6 RETURN to confirm the current setting and go back ...

Страница 15: ...ology please understand that there may be times when pixels may be lost or remain stuck flashing Also be aware that continuously monitoring a high temperature object beyond a certain period of time may produce an afterimage In cases where the product installation site experiences a sudden change in temperature dropping by 15 C or more the camera s focus will become blurred with regards to subjects...

Страница 16: ...ddress Equipment Type Environment Security IR Camera Model Name SDC 425P SDC 425PH SDC 425PD Beginning Serial NO S8030001 Year of Manufacture 2009 03 01 Conformance to EN 50081 1 1992 EMC Directive 89 336 EEC and 92 31 EEC EN 50130 4 1996 We the undersigned hereby declare that the equipment specified above conforms to the above Directive s Manufacturer SAMSUNGTECHWIN CO LTD LegalRepresentativeinEu...

Страница 17: ......

Отзывы: